These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

160 related articles for article (PubMed ID: 15382199)

  • 1. Urinary bladder volumetry by means of a single retrosymphysically implantable ultrasound unit.
    Seif C; Herberger B; Cherwon E; Martinez Portillo FJ; Molitor M; Stieglitz T; Böhler G; Zendler S; Jünemann KP; Braun PM
    Neurourol Urodyn; 2004; 23(7):680-4. PubMed ID: 15382199
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Volumetry of the urinary bladder with implantable ultrasound sensors].
    Scheepe JR; Bross S; Braun P; Seif C; Becker K; Nguyen XP; Alken P; Jünemann KP; Schumacher S
    Urologe A; 2000 May; 39(3):235-9. PubMed ID: 10872248
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Design and evaluation of a new bladder volume monitor.
    Wang J; Hou C; Zheng X; Zhang W; Chen A; Xu Z
    Arch Phys Med Rehabil; 2009 Nov; 90(11):1944-7. PubMed ID: 19887221
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Continuous registration of the filling volume of the human urinary bladder].
    Preussner PR
    Biomed Tech (Berl); 1991 Nov; 36(11):285-7. PubMed ID: 1768774
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Efficacy and problems of bladder volume measurement using portable three dimensional ultrasound scanning device--in particular, on measuring bladder volume lower than 100ml].
    Oh-Oka H; Nose R
    Nihon Hinyokika Gakkai Zasshi; 2005 Sep; 96(6):601-9. PubMed ID: 16218402
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Telemetric monitoring of bladder function in female Göttingen minipigs.
    Huppertz ND; Kirschner-Hermanns R; Tolba RH; Grosse JO
    BJU Int; 2015 Nov; 116(5):823-32. PubMed ID: 25682883
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Recommendations for the urodynamic examination in the investigation of non-neurological female urinary incontinence].
    Hermieu JF;
    Prog Urol; 2007 Nov; 17(6 Suppl 2):1264-84. PubMed ID: 18214138
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Portable ultrasonography and bladder volume accuracy--a comparative study using three-dimensional ultrasonography.
    Ghani KR; Pilcher J; Rowland D; Patel U; Nassiri D; Anson K
    Urology; 2008 Jul; 72(1):24-8. PubMed ID: 18400276
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Portable bladder ultrasonography: a new technic for the urological management of pediatric spinal cord damage].
    Mercurella A; Campobasso P; Musi L
    Pediatr Med Chir; 1997; 19(3):197-8. PubMed ID: 9340610
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Combined ultrasound-urodynamic study in paraplegic patients].
    Colombo T; Rauchenwald M; Dörfler O; Petritsch PH
    Urologe A; 1992 Sep; 31(5):310-4. PubMed ID: 1302412
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Feasibility of approximate measurement of bladder volume in male patients using the Lilium α-200 portable ultrasound bladder scanner.
    Kamei J; Watanabe D; Homma Y; Kume H; Igawa Y
    Low Urin Tract Symptoms; 2019 May; 11(3):169-173. PubMed ID: 30854772
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Bladder volume measurements with a limited number of fixed ultrasound beams.
    Palanchon P; van Loon D; Bangma CH; Bom N
    Ultrasound Med Biol; 2004 Mar; 30(3):289-94. PubMed ID: 15063510
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Bladder augmentation using the gastrointestinal tract. Indication, follow up and complications.
    Escudero RM; Patiño GE; Fernández ER; Gil MJ; García EL; Alonso AH; Piniés GO; Sánchez JP; Fernández CH
    Arch Esp Urol; 2011 Dec; 64(10):953-9. PubMed ID: 22228893
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Experimental development of a fixed volume, gravity draining, prosthetic urinary bladder.
    Gleeson MJ; Anderson S; Homsy C; Griffith DP
    ASAIO Trans; 1990; 36(3):M429-32. PubMed ID: 2252719
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of electrical impedance tomography for determination of urinary bladder volume: comparison with standard ultrasound methods in healthy volunteers.
    Leonhäuser D; Castelar C; Schlebusch T; Rohm M; Rupp R; Leonhardt S; Walter M; Grosse JO
    Biomed Eng Online; 2018 Jul; 17(1):95. PubMed ID: 30005629
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Acute lower urinary tract dysfunction (LUTD) following traumatic brain injury (TBI) in rats.
    Moody BJ; Liberman C; Zvara P; Smith PP; Freeman K; Zvarova K
    Neurourol Urodyn; 2014 Sep; 33(7):1159-64. PubMed ID: 24038177
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A noninvasive ultrasonographic method to evaluate bladder function recovery in spinal cord injured rats.
    Keirstead HS; Fedulov V; Cloutier F; Steward O; Duel BP
    Exp Neurol; 2005 Jul; 194(1):120-7. PubMed ID: 15899249
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Ultrasound cystometry with reference to urinary bladder form and bladder filling].
    Knorr H; Strauss I; Seichert N
    Ultraschall Med; 1990 Jun; 11(3):150-4. PubMed ID: 2200118
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Correlation between ultrasonographic bladder measurements and urodynamic findings in children with recurrent urinary tract infection.
    Yeung CK; Sreedhar B; Leung YF; Sit KY
    BJU Int; 2007 Mar; 99(3):651-5. PubMed ID: 17092286
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Transrectal sonographic voiding cystourethrography: studies in neuromuscular bladder dysfunction.
    Shapeero LG; Friedland GW; Perkash I
    AJR Am J Roentgenol; 1983 Jul; 141(1):83-90. PubMed ID: 6602535
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.