165 related articles for article (PubMed ID: 1538332)
21. Design and properties of maxillofacial prosthetic materials.
Andreopoulos AG; Theophanides T
Med Device Technol; 1993 Nov; 4(9):20-5. PubMed ID: 10146502
[TBL] [Abstract][Full Text] [Related]
22. Prosthetic rehabilitation of an external auricle defect with silicone rubber using extrinsic staining.
Sun T; Shao L; Zhao Y
J Craniofac Surg; 2013 May; 24(3):e302-5. PubMed ID: 23715000
[TBL] [Abstract][Full Text] [Related]
23. Adhesion of silicone to polyurethane in maxillofacial prostheses.
Wang R; Collard SM; Lemon J
Int J Prosthodont; 1994; 7(1):43-9. PubMed ID: 8179781
[TBL] [Abstract][Full Text] [Related]
24. Custom fabricated silicone rubber implants for tissue augmentation--a review.
Raval P; Schaaf NG
J Prosthet Dent; 1981 Apr; 45(4):432-4. PubMed ID: 7014845
[TBL] [Abstract][Full Text] [Related]
25. An implant-supported auricular prosthesis: a team effort between two South African tertiary institutions.
Geerts GA; Lombaard G
SADJ; 2002 Oct; 57(10):395-8. PubMed ID: 12518691
[No Abstract] [Full Text] [Related]
26. Judson C. Hickey Scientific Writing Award Winner. A method of fabrication of a facial prosthesis that improves retention and durability: a clinical report.
Marion LR; Rothenberger SL; Minsley GE
J Prosthet Dent; 1997 May; 77(5):457-60. PubMed ID: 9151262
[TBL] [Abstract][Full Text] [Related]
27. An improved ear prosthesis in silicone rubber incorporating an adhesive surface.
Snow RS
Br J Plast Surg; 1975 Oct; 28(4):289-91. PubMed ID: 1191873
[No Abstract] [Full Text] [Related]
28. Fabrication of a provisional nasal prosthesis.
Rosen EB; Golden M; Huryn JM
J Prosthet Dent; 2014 Nov; 112(5):1308-10. PubMed ID: 25277039
[TBL] [Abstract][Full Text] [Related]
29. Simplified fabrication of orbital prostheses using posterior attachment for the artificial eye.
Shifman A
J Prosthet Dent; 1993 Jan; 69(1):73-6. PubMed ID: 8455172
[TBL] [Abstract][Full Text] [Related]
30. Adhesive retention of silicone and chlorinated polyethylene for maxillofacial prostheses.
Kiat-Amnuay S; Waters PJ; Roberts D; Gettleman L
J Prosthet Dent; 2008 Jun; 99(6):483-8. PubMed ID: 18514671
[TBL] [Abstract][Full Text] [Related]
31. Color stability of elastomers for maxillofacial appliances.
Craig RG; Koran A; Yu R; Spencer J
J Dent Res; 1978; 57(9-10):866-71. PubMed ID: 281358
[TBL] [Abstract][Full Text] [Related]
32. Assisted retention of a hearing device in an implant-retained auricular prosthesis.
Taft RM; von Gonten AS; Wheeler ST
J Prosthet Dent; 2001 Oct; 86(4):386-9. PubMed ID: 11677533
[TBL] [Abstract][Full Text] [Related]
33. Comparison of the physical properties of two types of polydimethyl siloxane for fabrication of facial prostheses.
Sanchez RA; Moore DJ; Cruz DL; Chappell R
J Prosthet Dent; 1992 May; 67(5):679-82. PubMed ID: 1527755
[TBL] [Abstract][Full Text] [Related]
34. Effect of multi-adhesive layering on retention of extraoral maxillofacial silicone prostheses in vivo.
Kiat-Amnuay S; Gettleman L; Goldsmith LJ
J Prosthet Dent; 2004 Sep; 92(3):294-8. PubMed ID: 15343167
[TBL] [Abstract][Full Text] [Related]
35. Alternative processing technique for MDX4-4210.
Alfano SG; Taft RM
J Prosthet Dent; 2001 Sep; 86(3):327. PubMed ID: 11552175
[No Abstract] [Full Text] [Related]
36. [Long-term experience with silicone implants in the face].
Spitalny HH; Lemperle G
Handchir Mikrochir Plast Chir; 1982; 14(1):29-35. PubMed ID: 7182281
[TBL] [Abstract][Full Text] [Related]
37. Silicone Facial Prosthesis: A Preliminary Report on Silicone Adhesion to Magnet.
Kim SM; Cho YJ; Eo MY; Kim JS; Lee SK
J Craniofac Surg; 2018 Jan; 29(1):e6-e8. PubMed ID: 29023292
[TBL] [Abstract][Full Text] [Related]
38. Use of medical-grade methyl triacetoxy silane crosslinked silicone for facial prostheses.
Udagama A; Drane JB
J Prosthet Dent; 1982 Jul; 48(1):86-8. PubMed ID: 6955510
[TBL] [Abstract][Full Text] [Related]
39. Porosity and color of maxillofacial silicone elastomer.
Hatamleh MM; Watts DC
J Prosthodont; 2011 Jan; 20(1):60-6. PubMed ID: 21054642
[TBL] [Abstract][Full Text] [Related]
40. Fabrication of perforated silicone rubber implant.
Raval P; Schaaf NG; Kielich M
J Prosthet Dent; 1981 Apr; 45(4):449-51. PubMed ID: 6939852
[No Abstract] [Full Text] [Related]
[Previous] [Next] [New Search]