These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
145 related articles for article (PubMed ID: 1538597)
1. The influence of harvesting technique on endothelial preservation in saphenous veins. Dries D; Mohammad SF; Woodward SC; Nelson RM J Surg Res; 1992 Mar; 52(3):219-25. PubMed ID: 1538597 [TBL] [Abstract][Full Text] [Related]
2. Use of cold cardioplegic solution for vein graft distention and preservation: a light and scanning electron microscopic study. Kurusz M; Christman EW; Derrick JR; Tyers GF; Williams EH Ann Thorac Surg; 1981 Jul; 32(1):68-74. PubMed ID: 6972750 [TBL] [Abstract][Full Text] [Related]
3. Optimal preparation techniques for human saphenous vein grafts. Gundry SR; Jones M; Ishihara T; Ferrans VJ Surgery; 1980 Dec; 88(6):785-94. PubMed ID: 7444762 [TBL] [Abstract][Full Text] [Related]
4. Localization of nitric oxide synthase in saphenous vein grafts harvested with a novel "no-touch" technique: potential role of nitric oxide contribution to improved early graft patency rates. Tsui JC; Souza DS; Filbey D; Karlsson MG; Dashwood MR J Vasc Surg; 2002 Feb; 35(2):356-62. PubMed ID: 11854735 [TBL] [Abstract][Full Text] [Related]
5. "No-touch" technique using saphenous vein harvested with its surrounding tissue for coronary artery bypass grafting maintains an intact endothelium. Souza DS; Christofferson RH; Bomfim V; Filbey D Scand Cardiovasc J; 1999; 33(6):323-9. PubMed ID: 10622542 [TBL] [Abstract][Full Text] [Related]
6. Novel no-touch technique of harvesting the saphenous vein for coronary artery bypass grafting. Rueda Fd; Souza D; Lima Rde C; Menezes A; Johansson B; Dashwood M; Thé E; Gesteira M; Escobar M; Vasconcelos F Arq Bras Cardiol; 2008 Jun; 90(6):356-62. PubMed ID: 18592087 [TBL] [Abstract][Full Text] [Related]
7. Retaining perivascular tissue of human saphenous vein grafts protects against surgical and distension-induced damage and preserves endothelial nitric oxide synthase and nitric oxide synthase activity. Dashwood MR; Savage K; Tsui JC; Dooley A; Shaw SG; Fernández Alfonso MS; Bodin L; Souza DS J Thorac Cardiovasc Surg; 2009 Aug; 138(2):334-40. PubMed ID: 19619776 [TBL] [Abstract][Full Text] [Related]
8. Saphenous vein endothelial cell viability: a comparative study of endoscopic and open saphenectomy for coronary artery bypass grafting. Alrawi SJ; Raju R; Alshkaki G; Acinapura AJ; Cunningham JN JSLS; 2001; 5(1):37-45. PubMed ID: 11303993 [TBL] [Abstract][Full Text] [Related]
9. Comparison of conventional and no-touch techniques in harvesting saphenous vein for coronary artery bypass grafting in view of endothelial damage. Sen O; Gonca S; Solakoglu S; Dalcik H; Dalcik C; Ozkara A Heart Surg Forum; 2013 Aug; 16(4):E177-83. PubMed ID: 23958526 [TBL] [Abstract][Full Text] [Related]
10. Preserved vasodilatory response to nitroglycerin in saphenous vein bypass grafts. Berglund H; Luo H; Nishioka T; Eigler NL; Kim CJ; Tabak SW; Siegel RJ Circulation; 1996 Dec; 94(11):2871-6. PubMed ID: 8941115 [TBL] [Abstract][Full Text] [Related]
11. Improved patency in vein grafts harvested with surrounding tissue: results of a randomized study using three harvesting techniques. Souza DS; Dashwood MR; Tsui JC; Filbey D; Bodin L; Johansson B; Borowiec J Ann Thorac Surg; 2002 Apr; 73(4):1189-95. PubMed ID: 11996262 [TBL] [Abstract][Full Text] [Related]
12. The factors influencing early patency of coronary artery bypass vein grafts: correlation of angiographic and ultrastructural findings. Catinella FP; Cunningham JN; Srungaram RK; Baumann FG; Nathan IM; Glassman EA; Knopp EA; Spencer FC J Thorac Cardiovasc Surg; 1982 May; 83(5):686-700. PubMed ID: 6978974 [TBL] [Abstract][Full Text] [Related]
13. Multi-photon microscopic evaluation of saphenous vein endothelium and its preservation with a new solution, GALA. Thatte HS; Biswas KS; Najjar SF; Birjiniuk V; Crittenden MD; Michel T; Khuri SF Ann Thorac Surg; 2003 Apr; 75(4):1145-52; discussion 1152. PubMed ID: 12683553 [TBL] [Abstract][Full Text] [Related]
14. Improved preservation of saphenous vein grafts by the use of glyceryl trinitrate-verapamil solution during harvesting. Roubos N; Rosenfeldt FL; Richards SM; Conyers RA; Davis BB Circulation; 1995 Nov; 92(9 Suppl):II31-6. PubMed ID: 7586430 [TBL] [Abstract][Full Text] [Related]
15. Structural, biochemical and functional effects of distending pressure in the human saphenous vein: implications for bypass grafting. Chester AH; Buttery LD; Borland JA; Springall DR; Rothery S; Severs NJ; Polak JM; Yacoub MH Coron Artery Dis; 1998; 9(2-3):143-51. PubMed ID: 9647416 [TBL] [Abstract][Full Text] [Related]
17. Endothelial preservation of the minimally manipulated saphenous vein composite graft: histologic and immunohistochemical study. Hwang HY; Kim MA; Seo JW; Kim KB J Thorac Cardiovasc Surg; 2012 Sep; 144(3):690-6. PubMed ID: 22306225 [TBL] [Abstract][Full Text] [Related]
18. An improved technique for preservation of endothelial morphology in vein grafts. LoGerfo FW; Quist WC; Crawshaw HM; Haudenschild C Surgery; 1981 Dec; 90(6):1015-24. PubMed ID: 7313936 [TBL] [Abstract][Full Text] [Related]
19. Preserved endothelial integrity and nitric oxide synthase in saphenous vein grafts harvested by a 'no-touch' technique. Tsui JC; Souza DS; Filbey D; Bomfim V; Dashwood MR Br J Surg; 2001 Sep; 88(9):1209-15. PubMed ID: 11531869 [TBL] [Abstract][Full Text] [Related]
20. Microscopic and ultrastructural evaluation of the saphenous vein endothelium for CABG prepared by the no touch technique. Silva VF; Ishigai MM; Freymüller E; Branco JN; Gaia DF; Gabriel EA; Romão RA; Buffolo E Rev Bras Cir Cardiovasc; 2008; 23(3):323-9. PubMed ID: 19082319 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]