375 related articles for article (PubMed ID: 15388146)
1. Improved radial dose function estimation using current version MCNP Monte-Carlo simulation: Model 6711 and ISC3500 125I brachytherapy sources.
Duggan DM
Appl Radiat Isot; 2004 Dec; 61(6):1443-50. PubMed ID: 15388146
[TBL] [Abstract][Full Text] [Related]
2. Brachytherapy dosimetry of 125I and 103Pd sources using an updated cross section library for the MCNP Monte Carlo transport code.
Bohm TD; DeLuca PM; DeWerd LA
Med Phys; 2003 Apr; 30(4):701-11. PubMed ID: 12722822
[TBL] [Abstract][Full Text] [Related]
3. Monte Carlo calculated TG-43 dosimetry parameters for the SeedLink 125Iodine brachytherapy system.
Medich DC; Munro JJ
Med Phys; 2003 Sep; 30(9):2503-8. PubMed ID: 14528972
[TBL] [Abstract][Full Text] [Related]
4. On the development of consensus values of reference dosimetry parameters for interstitial brachytherapy sources.
Chan GH; Nath R; Williamson JF;
Med Phys; 2004 May; 31(5):1040-5. PubMed ID: 15191290
[TBL] [Abstract][Full Text] [Related]
5. Polymer gel dosimetry close to an 125I interstitial brachytherapy seed.
Pantelis E; Lymperopoulou G; Papagiannis P; Sakelliou L; Stiliaris E; Sandilos P; Seimenis I; Kozicki M; Rosiak JM
Phys Med Biol; 2005 Sep; 50(18):4371-84. PubMed ID: 16148399
[TBL] [Abstract][Full Text] [Related]
6. Dose verification with Monte Carlo technique for prostate brachytherapy implants with (125)I sources.
Zhang H; Baker C; McKinsey R; Meigooni A
Med Dosim; 2005; 30(2):85-91. PubMed ID: 15922174
[TBL] [Abstract][Full Text] [Related]
7. Calculated microdosimetric characteristics of 125I and 103Pd brachytherapy seeds at different depths in water.
Wuu CS; Chen J
Radiat Prot Dosimetry; 2006; 122(1-4):506-8. PubMed ID: 17189276
[TBL] [Abstract][Full Text] [Related]
8. Theoretical and experimental determination of dosimetric characteristics for ADVANTAGE Pd-103 brachytherapy source.
Meigooni AS; Dini SA; Awan SB; Dou K; Koona RA
Appl Radiat Isot; 2006 Aug; 64(8):881-7. PubMed ID: 16713277
[TBL] [Abstract][Full Text] [Related]
9. Patient-specific Monte Carlo dose calculations for high-dose-rate endorectal brachytherapy with shielded intracavitary applicator.
Poon E; Williamson JF; Vuong T; Verhaegen F
Int J Radiat Oncol Biol Phys; 2008 Nov; 72(4):1259-66. PubMed ID: 18954720
[TBL] [Abstract][Full Text] [Related]
10. Dosimetric characteristic of a new 125I brachytherapy source.
Sadeghi M; Khanmohammadi Z
Radiat Prot Dosimetry; 2011 Nov; 147(3):451-6. PubMed ID: 21233096
[TBL] [Abstract][Full Text] [Related]
11. A new human eye model for ophthalmic brachytherapy dosimetry.
Yoriyaz H; Sanchez A; dos Santos A
Radiat Prot Dosimetry; 2005; 115(1-4):316-9. PubMed ID: 16381737
[TBL] [Abstract][Full Text] [Related]
12. A semi-analytic approach to determine dose rate constant of brachytherapy sources in compliance with AAPM TG 60 formalism.
Selvam TP; Nagarajan PS; Rajan KN; Sethulakshmi P; Bhatt BC
Australas Phys Eng Sci Med; 2003 Dec; 26(4):179-84. PubMed ID: 14995063
[TBL] [Abstract][Full Text] [Related]
13. Brachytherapy dosimetry parameters calculated for a new 103Pd source.
Rivard MJ; Melhus CS; Kirk BL
Med Phys; 2004 Sep; 31(9):2466-70. PubMed ID: 15487726
[TBL] [Abstract][Full Text] [Related]
14. A Monte Carlo evaluation of the dosimetric characteristics of the EchoSeed Model 6733 (125)I brachytherapy source.
Sowards KT; Meigooni AS
Brachytherapy; 2002; 1(4):227-32. PubMed ID: 15062171
[TBL] [Abstract][Full Text] [Related]
15. Monte carlo investigation of the dosimetric properties of the new 103Pd BrachySeedPd-103 Model Pd-1 source.
Chan GH; Prestwich WV
Med Phys; 2002 Sep; 29(9):1984-90. PubMed ID: 12349919
[TBL] [Abstract][Full Text] [Related]
16. A practical Monte Carlo MU verification tool for IMRT quality assurance.
Fan J; Li J; Chen L; Stathakis S; Luo W; Du Plessis F; Xiong W; Yang J; Ma CM
Phys Med Biol; 2006 May; 51(10):2503-15. PubMed ID: 16675866
[TBL] [Abstract][Full Text] [Related]
17. Comparison of dose distributions around the pulsed-dose-rate Fletcher-Williamson and the low-dose-rate Fletcher-Suit-Delclos ovoids: a Monte Carlo study.
Price MJ; Gifford KA; Horton J; Lawyer A; Eifel P; Mourtada F
Phys Med Biol; 2006 Aug; 51(16):4083-94. PubMed ID: 16885626
[TBL] [Abstract][Full Text] [Related]
18. Monte Carlo and thermoluminescence dosimetry of the new IsoSeed model I25.S17 125I interstitial brachytherapy seed.
Lymperopoulou G; Papagiannis P; Sakelliou L; Karaiskos P; Sandilos P; Przykutta A; Baltas D
Med Phys; 2005 Nov; 32(11):3313-7. PubMed ID: 16370418
[TBL] [Abstract][Full Text] [Related]
19. Benchmark of penelope for low and medium energy X-rays.
Chica U; Anguiano M; Lallena AM
Phys Med; 2009 Jun; 25(2):51-7. PubMed ID: 18495512
[TBL] [Abstract][Full Text] [Related]
20. Dosimetric characterization of 142Pr glass seeds for brachytherapy.
Jung JW; Reece WD
Appl Radiat Isot; 2008 Apr; 66(4):441-9. PubMed ID: 18171619
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]