BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

210 related articles for article (PubMed ID: 15388148)

  • 1. Comparison of a digital and an analog signal processing system for neutron inelastic gamma-ray spectrometry.
    Mitra S; Wielopolski L; Hendrey G
    Appl Radiat Isot; 2004 Dec; 61(6):1463-8. PubMed ID: 15388148
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Testing of properties of digital modules used in gamma-ray spectrometry.
    Dryak P; Kovar P
    Appl Radiat Isot; 2004; 60(2-4):203-6. PubMed ID: 14987643
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Neutron fluence rate measurement using prompt gamma rays.
    Vega-Carrillo HR; Manzanares-Acuña E; Hernández-Dávila VM; Chacón-Ruíz A; Gallego E; Lorente A
    Radiat Prot Dosimetry; 2007; 126(1-4):265-8. PubMed ID: 17513856
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hydrogen, carbon and oxygen determination in proxy material samples using a LaBr3:Ce detector.
    Naqvi AA; Al-Matouq FA; Khiari FZ; Isab AA; Raashid M; Khateeb-ur-Rehman
    Appl Radiat Isot; 2013 Aug; 78():145-50. PubMed ID: 23673256
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Metrological characterization of the ADONIS system used in gamma-ray spectrometry.
    Plagnard J; Morel J; Tuan AT
    Appl Radiat Isot; 2004; 60(2-4):179-83. PubMed ID: 14987639
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation the nonlinear response function of a 3 x 3 in NaI scintillation detector for PGNAA applications.
    Miri Hakimabad H; Panjeh H; Vejdani-Noghreiyan A
    Appl Radiat Isot; 2007 Aug; 65(8):918-26. PubMed ID: 17485218
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Performance evaluation and optimization for a newly developed digital list-mode data acquisition Compton suppression spectrometer.
    Zhang W; Keeshan B; Mekarski P; Yi J; Ungar K
    Appl Radiat Isot; 2013 Nov; 81():96-102. PubMed ID: 23497957
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An approximation for response function to gamma-rays of NaI(Tl) detectors up to 1.5 MeV.
    Cengiz A
    Appl Radiat Isot; 2008 Oct; 66(10):1371-6. PubMed ID: 18486481
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monte Carlo assessment of soil moisture effect on high-energy thermal neutron capture gamma-ray by 14N.
    Pazirandeh A; Azizi M; Farhad Masoudi S
    Appl Radiat Isot; 2006 Jan; 64(1):1-6. PubMed ID: 16081298
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development of a control system for pulsed-electron spin resonance spectrometers.
    Mizuta Y; Kazama S; Ohba Y; Sakai N; Yamamoto Y; Shimoyama Y
    Rev Sci Instrum; 2008 Apr; 79(4):044705. PubMed ID: 18447542
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Determination of photon attenuation coefficient, porosity and field capacity of soil by gamma-ray transmission for 60, 356 and 662 keV gamma rays.
    Demir D; Un A; Ozgül M; Sahin Y
    Appl Radiat Isot; 2008 Dec; 66(12):1834-7. PubMed ID: 18554919
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [The use of sigma-delta analog-digital conversion in multichannel electrocardiographs].
    Kurikov SF; Prilutskiĭ DA; Selishchev SV
    Med Tekh; 1997; (4):7-10. PubMed ID: 9379865
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Spatial resolution limit study of a CCD camera and scintillator based neutron imaging system according to MTF determination and analysis.
    Kharfi F; Denden O; Bourenane A; Bitam T; Ali A
    Appl Radiat Isot; 2012 Jan; 70(1):162-6. PubMed ID: 22014891
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The 4.438 MeV gamma to neutron ratio for the Am-Be neutron source.
    Liu Z; Chen J; Zhu P; Li Y; Zhang G
    Appl Radiat Isot; 2007 Dec; 65(12):1318-21. PubMed ID: 17574426
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A feasibility study of in vivo 14-MeV neutron activation analysis using the associated particle technique.
    Garrett R; Mitra S
    Med Phys; 1991; 18(5):916-20. PubMed ID: 1961154
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The digital pacemaker.
    Love CJ
    Pacing Clin Electrophysiol; 2004 Jun; 27(6 Pt 1):707-8. PubMed ID: 15189523
    [No Abstract]   [Full Text] [Related]  

  • 17. Effect of detector collimator and sample thickness on 0.662 MeV multiply Compton-scattered gamma rays.
    Singh M; Singh G; Sandhu BS; Singh B
    Appl Radiat Isot; 2006 Mar; 64(3):373-8. PubMed ID: 16307888
    [TBL] [Abstract][Full Text] [Related]  

  • 18. On line gamma-ray spectrometry at open sea.
    Tsabaris C; Ballas D
    Appl Radiat Isot; 2005 Jan; 62(1):83-9. PubMed ID: 15498689
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Use of digital technics in the display of electromyography signals].
    Holl G
    EEG EMG Z Elektroenzephalogr Elektromyogr Verwandte Geb; 1989 Jun; 20(2):76-80. PubMed ID: 2503357
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Classifying threats with a 14-MeV neutron interrogation system.
    Strellis D; Gozani T
    Appl Radiat Isot; 2005; 63(5-6):799-803. PubMed ID: 15985373
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.