These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 1539483)

  • 21. [Minimal flow anesthesia in newborn infants--advantages and risks].
    Gebhardt R; Weiser UK
    Anaesthesiol Reanim; 1999; 24(2):41-6. PubMed ID: 10372434
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Leak compensation in positive pressure ventilators: a lung model study.
    Mehta S; McCool FD; Hill NS
    Eur Respir J; 2001 Feb; 17(2):259-67. PubMed ID: 11334129
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Respiratory muscle performance, pulmonary mechanics, and gas exchange between the BiPAP S/T-D system and the Servo Ventilator 900C with bilevel positive airway pressure ventilation following gradual pressure support weaning.
    Patel RG; Petrini MF
    Chest; 1998 Nov; 114(5):1390-6. PubMed ID: 9824020
    [TBL] [Abstract][Full Text] [Related]  

  • 24. High flow closed circuit anaesthesia.
    Verkaaik AP; Van Dijk G
    Anaesth Intensive Care; 1994 Aug; 22(4):426-34. PubMed ID: 7978208
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Monitoring for disconnection: ventilators with bellows rising on expiration can deliver tidal volumes after disconnection.
    Gravenstein JS; Nederstigt JA
    J Clin Monit; 1990 Jul; 6(3):207-10. PubMed ID: 2380751
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The effect of a bellows leak in an Ohmeda 7810 ventilator on room contamination, inspired oxygen, airway pressure, and tidal volume.
    Lampotang S; Sanchez JC; Chen B; Gravenstein N
    Anesth Analg; 2005 Jul; 101(1):151-4, table of contents. PubMed ID: 15976223
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Effect of inspiratory time on tidal volume delivery in anesthesia and intensive care unit ventilators operating in pressure control mode.
    Tung A; Drum ML; Morgan S
    J Clin Anesth; 2005 Feb; 17(1):8-15. PubMed ID: 15721723
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Evaluation of a new operating room ventilator with volume-controlled ventilation: the Ohmeda 7900.
    Rothschiller JL; Uejima T; Dsida RM; Coté CJ
    Anesth Analg; 1999 Jan; 88(1):39-42. PubMed ID: 9895063
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Tidal volume changes due to the interaction of anesthesia machine and anesthesia ventilator.
    Gravenstein N; Banner MJ; McLaughlin G
    J Clin Monit; 1987 Jul; 3(3):187-90. PubMed ID: 3475406
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Measurement of respiratory mechanics using the Siemens Servo Ventilator 900C.
    Sly PD; Bates JH; Milic-Emili J
    Pediatr Pulmonol; 1987; 3(6):400-5. PubMed ID: 3480499
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Fresh gas flow and carbon dioxide rebreathing in a low pressure semi-open anaesthesia system.
    Tweed WA; Amatya R; Lekhak BD
    Can J Anaesth; 1993 Nov; 40(11):1096-101. PubMed ID: 8269574
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Pressure controlled-inverse ratio ventilation and pulmonary gas exchange during lower abdominal surgery.
    Tweed WA; Tan PL
    Can J Anaesth; 1992 Dec; 39(10):1036-40. PubMed ID: 1464129
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Tidal volume and airway pressure under percutaneous transtracheal ventilation without a jet ventilator: comparison of high-flow oxygen ventilation and manual ventilation in complete and incomplete upper airway obstruction models.
    Sasano N; Tanaka A; Muramatsu A; Fujita Y; Ito S; Sasano H; Sobue K
    J Anesth; 2014 Jun; 28(3):341-6. PubMed ID: 24212332
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The influence of CO2 production and physiological deadspace on end-tidal CO2 during controlled ventilation: a study using a mechanical model.
    Stockwell MA; Bruce W; Soni N
    Anaesth Intensive Care; 1989 Nov; 17(4):482-6. PubMed ID: 2512821
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Pressure support and pressure assist/control: are there differences? An evaluation of the newest intensive care unit ventilators.
    Williams P; Kratohvil J; Ritz R; Hess DR; Kacmarek RM
    Respir Care; 2000 Oct; 45(10):1169-81. PubMed ID: 11054896
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A low flow open circle system for anaesthesia. Part 2: Clinical evaluation.
    Holdcroft A; Chakrabarti MK; Whitwam JG
    Anaesthesia; 1990 Apr; 45(4):318-21. PubMed ID: 2186649
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Using conventional infant ventilators at unconventional rates.
    Boros SJ; Bing DR; Mammel MC; Hagen E; Gordon MJ
    Pediatrics; 1984 Oct; 74(4):487-92. PubMed ID: 6384912
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A closed rebreathing system for dose maintenance during Partial Liquid Ventilation.
    Schrader B; Westenskow D; Kofoed S; Durst K; Orr J; Flanagan C; Mazzoni M; Hoffman J; Sekins M
    Biomed Instrum Technol; 1999; 33(4):373-82. PubMed ID: 10459425
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Circle systems with a coaxial inspiratory limb. Investigation with a lung model.
    Cook LB; Chakrabarti MK
    Anaesthesia; 1996 Mar; 51(3):247-54. PubMed ID: 8712325
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [The effect of fresh-gas decoupling on respiratory volume. Draegar Sulla 808V anesthesia ventilator].
    Biro P
    Anaesthesist; 1997 Nov; 46(11):949-52. PubMed ID: 9490582
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.