These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

112 related articles for article (PubMed ID: 1539797)

  • 1. Failure of Ohmeda Tec 4 safety interlock.
    Hartle AJ; Daum RE
    Anaesthesia; 1992 Feb; 47(2):171. PubMed ID: 1539797
    [No Abstract]   [Full Text] [Related]  

  • 2. Failure of vaporizer interlock mechanism.
    Buettner AU
    Anaesth Intensive Care; 2000 Aug; 28(4):451-2. PubMed ID: 10969380
    [No Abstract]   [Full Text] [Related]  

  • 3. A potential circuit leak with Tec 5 vaporizers.
    Chun NL
    Anesthesiology; 1997 Dec; 87(6):1599. PubMed ID: 9416760
    [No Abstract]   [Full Text] [Related]  

  • 4. North American Drager's Narcomed 3: interlock failures.
    Smith CA
    AANA J; 1995 Jun; 63(3):187. PubMed ID: 7631571
    [No Abstract]   [Full Text] [Related]  

  • 5. An unusual cause of faulty Tec 7 vaporizer.
    Ghai B; Makkar JK
    Anesth Analg; 2005 Dec; 101(6):1890-1891. PubMed ID: 16301291
    [No Abstract]   [Full Text] [Related]  

  • 6. Tec 6 recall.
    Riddle RT
    Anesthesiology; 1994 Sep; 81(3):791-2. PubMed ID: 8092538
    [No Abstract]   [Full Text] [Related]  

  • 7. The desflurane Tec 6 vaporizer.
    Graham SG
    Br J Anaesth; 1994 Apr; 72(4):470-3. PubMed ID: 8155455
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pumping effect in Ohmeda Tec 5 vaporizers.
    Loeb R; Santos B
    J Clin Monit; 1995 Sep; 11(5):348. PubMed ID: 7595693
    [No Abstract]   [Full Text] [Related]  

  • 9. [A new parking cart for Selectatec vaporizers].
    Inoue T
    Masui; 1992 May; 41(5):864-6. PubMed ID: 1608169
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Vaporizers--serviced and checked?
    Gill RS; Lack JA
    Anaesthesia; 1991 Aug; 46(8):695-7. PubMed ID: 1887987
    [No Abstract]   [Full Text] [Related]  

  • 11. Performance of BOC Ohmeda Tec 3 and Tec 4 vaporisers following tipping.
    Scott DM
    Anaesth Intensive Care; 1991 Aug; 19(3):441-3. PubMed ID: 1767917
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The Blease Datum anaesthesia vaporiser and the backbar.
    Mishra S; Vasudevan A; Krishnappa S; Badhe A
    Anaesth Intensive Care; 2010 Jan; 38(1):209-10; author reply 210. PubMed ID: 20191802
    [No Abstract]   [Full Text] [Related]  

  • 13. Fault in a Selectatec manifold resulting in awareness.
    Lum ME; Ngan Kee WD; Robinson BJ
    Anaesth Intensive Care; 1992 Nov; 20(4):501-3. PubMed ID: 1463182
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The desflurane (Tec 6) vaporizer: design, design considerations and performance evaluation.
    Weiskopf RB; Sampson D; Moore MA
    Br J Anaesth; 1994 Apr; 72(4):474-9. PubMed ID: 8155456
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Potentially lethal failure of the vapor exclusion system.
    Silvasi DL; Haynes A; Brown AC
    Anesthesiology; 1989 Aug; 71(2):289-91. PubMed ID: 2757248
    [No Abstract]   [Full Text] [Related]  

  • 16. Vaporizer fill system leak.
    Urmey WE; Elliott W; Raemer DB
    Anesth Analg; 1988 Jul; 67(7):711. PubMed ID: 3382047
    [No Abstract]   [Full Text] [Related]  

  • 17. Defective Selectatec O-rings.
    Tighe SQ
    Anaesthesia; 1995 Jul; 50(7):668. PubMed ID: 7653788
    [No Abstract]   [Full Text] [Related]  

  • 18. The Selectatec system: another cause of total leakage.
    Hung CT; Chhieng CF
    Anaesth Intensive Care; 1992 Nov; 20(4):532-3. PubMed ID: 1463192
    [No Abstract]   [Full Text] [Related]  

  • 19. Vaporizer-selection system malfunction in the Dräger Narkomed 2C machine.
    Kee SS; Frenzel JC; Goravanchi F; Laman KA
    Anesthesiology; 2006 Apr; 104(4):890-1; discussion 891. PubMed ID: 16571990
    [No Abstract]   [Full Text] [Related]  

  • 20. Incorrectly adjusted vaporizer exclusion system.
    Viney JP; Gartrell AD
    Anesthesiology; 1994 Sep; 81(3):781. PubMed ID: 8092528
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.