These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
227 related articles for article (PubMed ID: 15449121)
1. Grit-blasted and hydroxyapatite-coated total hip arthroplasty: an 11- to 14-year follow-up study. Miyakawa S; Kawamura H; Mishima H; Yasumoto J J Orthop Sci; 2004; 9(5):462-7. PubMed ID: 15449121 [TBL] [Abstract][Full Text] [Related]
2. [Long-term experience with the combined ARBOND hydroxyapatite coating in implant osteointegration]. Landor I; Vavrík P; Jahoda D; Pokorný D; Ballay R; Sosna A Acta Chir Orthop Traumatol Cech; 2009 Jun; 76(3):172-8. PubMed ID: 19595277 [TBL] [Abstract][Full Text] [Related]
3. Role of hydroxyapatite coating in resisting wear particle migration and osteolysis around acetabular components. Coathup MJ; Blackburn J; Goodship AE; Cunningham JL; Smith T; Blunn GW Biomaterials; 2005 Jul; 26(19):4161-9. PubMed ID: 15664643 [TBL] [Abstract][Full Text] [Related]
4. Effect of hydroxyapatite coating on the radio-clinical results of a grit-blasted titanium alloy femoral taper. A case-control study of 198 cementless primary total hip arthroplasty with the Alloclassic™ system. Delaunay C Orthop Traumatol Surg Res; 2014 Nov; 100(7):739-44. PubMed ID: 25261173 [TBL] [Abstract][Full Text] [Related]
5. Comparison of proximal porous-coated and grit-blasted surfaces of hydroxyapatite-coated stems. Won YY; Dorr LD; Wan Z J Bone Joint Surg Am; 2004 Jan; 86(1):124-8. PubMed ID: 14711954 [TBL] [Abstract][Full Text] [Related]
6. Arc-deposited hydroxyapatite-coated cups: results at four to seven years. Capello WN; D'Antonio JA; Manley MT; Feinberg JR Clin Orthop Relat Res; 2005 Dec; 441():305-12. PubMed ID: 16331019 [TBL] [Abstract][Full Text] [Related]
7. Eight-year results of hydroxyapatite-coated hip arthroplasty. Chang JK; Chen CH; Huang KY; Wang GJ J Arthroplasty; 2006 Jun; 21(4):541-6. PubMed ID: 16781407 [TBL] [Abstract][Full Text] [Related]
8. Hydroxyapatite in total hip arthroplasty. Clinical results and critical issues. Capello WN; D'Antonio JA; Manley MT; Feinberg JR Clin Orthop Relat Res; 1998 Oct; (355):200-11. PubMed ID: 9917605 [TBL] [Abstract][Full Text] [Related]
9. The acetabular component in total hip arthroplasty. Evaluation of different fixation principles. Thanner J Acta Orthop Scand Suppl; 1999 Aug; 286():1-41. PubMed ID: 10572504 [TBL] [Abstract][Full Text] [Related]
10. The effects of surface roughness and polymethylmethacrylate precoating on the radiographic and clinical results of the Iowa hip prosthesis. A study of patients less than fifty years old. Sporer SM; Callaghan JJ; Olejniczak JP; Goetz DD; Johnston RC J Bone Joint Surg Am; 1999 Apr; 81(4):481-92. PubMed ID: 10225793 [TBL] [Abstract][Full Text] [Related]
11. Seven-year results of a tapered, titanium, hydroxyapatite-coated cementless femoral stem in primary total hip arthroplasty. Cho JH; Garino JP; Choo SK; Han KY; Kim JH; Oh HK Clin Orthop Surg; 2010 Dec; 2(4):214-20. PubMed ID: 21119937 [TBL] [Abstract][Full Text] [Related]
12. Results at a minimum of 10 years of follow-up for AMS and PerFix HA-coated cementless total hip arthroplasty: impact of cross-linked polyethylene on implant longevity. Nakashima Y; Sato T; Yamamoto T; Motomura G; Ohishi M; Hamai S; Akiyama M; Hirata M; Hara D; Iwamoto Y J Orthop Sci; 2013 Nov; 18(6):962-8. PubMed ID: 23963589 [TBL] [Abstract][Full Text] [Related]
13. Early failure of smooth hydroxyapatite-coated press-fit acetabular cup--7 years of follow-up. Cheung KW; Yung SH; Wong KC; Chiu KH J Arthroplasty; 2005 Aug; 20(5):627-31. PubMed ID: 16309999 [TBL] [Abstract][Full Text] [Related]
14. A randomized trial of hydroxyapatite coated prostheses in total hip arthroplasty. Yee AJ; Kreder HK; Bookman I; Davey JR Clin Orthop Relat Res; 1999 Sep; (366):120-32. PubMed ID: 10627726 [TBL] [Abstract][Full Text] [Related]
15. Total hip arthroplasty with an uncemented hydroxyapatite-coated tapered titanium stem: results at a minimum of 10 years' follow-up in 104 hips. Bodén H; Salemyr M; Sköldenberg O; Ahl T; Adolphson P J Orthop Sci; 2006 Mar; 11(2):175-9. PubMed ID: 16568390 [TBL] [Abstract][Full Text] [Related]
16. High survival rate of hydroxyapatite-coated hip prostheses: 100 consecutive hips followed for 10 years. Oosterbos CJ; Rahmy AI; Tonino AJ; Witpeerd W Acta Orthop Scand; 2004 Apr; 75(2):127-33. PubMed ID: 15180226 [TBL] [Abstract][Full Text] [Related]
17. Comparison of Hydroxyapatite-coated stems in total hip arthroplasty after a minimum 10-years follow-up. Gallo J; Landor I; Cechová I; Jahoda D Acta Chir Orthop Traumatol Cech; 2008 Oct; 75(5):339-46. PubMed ID: 19026187 [TBL] [Abstract][Full Text] [Related]
19. Hydroxyapatite-coated RM cup in primary hip arthroplasty. Ali MS; Kumar A Int Orthop; 2003; 27(2):90-3. PubMed ID: 12700931 [TBL] [Abstract][Full Text] [Related]
20. Long-term follow-up (11 years plus) results of JRI (Furlong) total hip arthroplasty in young patients: cause for concern regarding acetabular cup? Sharma DK; Brooks S Int Orthop; 2006 Oct; 30(5):375-80. PubMed ID: 16761147 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]