332 related articles for article (PubMed ID: 15468814)
1. Poly(vinyl alcohol) : a potential matrix for glucose oxidase immobilization?
Azila AA; Barbari T; Searson P
Med J Malaysia; 2004 May; 59 Suppl B():51-2. PubMed ID: 15468814
[TBL] [Abstract][Full Text] [Related]
2. Preparation of PVA membrane for immobilization of GOD for glucose biosensor.
Kumar J; D'Souza SF
Talanta; 2008 Mar; 75(1):183-8. PubMed ID: 18371866
[TBL] [Abstract][Full Text] [Related]
3. Development of amperometric biosensor for glucose based on a novel attractive enzyme immobilization matrix: calcium carbonate nanoparticles.
Shan D; Zhu M; Xue H; Cosnier S
Biosens Bioelectron; 2007 Mar; 22(8):1612-7. PubMed ID: 16920350
[TBL] [Abstract][Full Text] [Related]
4. Amperometric glucose biosensor based on layer-by-layer assembly of multilayer films composed of chitosan, gold nanoparticles and glucose oxidase modified Pt electrode.
Wu BY; Hou SH; Yin F; Li J; Zhao ZX; Huang JD; Chen Q
Biosens Bioelectron; 2007 Jan; 22(6):838-44. PubMed ID: 16675215
[TBL] [Abstract][Full Text] [Related]
5. Glucose biosensor based on the immobilization of glucose oxidase on electrochemically synthesized polypyrrole-poly(vinyl sulphonate) composite film by cross-linking with glutaraldehyde.
Colak O; Yaşar A; Cete S; Arslan F
Artif Cells Blood Substit Immobil Biotechnol; 2012 Oct; 40(5):354-61. PubMed ID: 22540929
[TBL] [Abstract][Full Text] [Related]
6. A soft and flexible biosensor using a phospholipid polymer for continuous glucose monitoring.
Chu M; Kudo H; Shirai T; Miyajima K; Saito H; Morimoto N; Yano K; Iwasaki Y; Akiyoshi K; Mitsubayashi K
Biomed Microdevices; 2009 Aug; 11(4):837-42. PubMed ID: 19365733
[TBL] [Abstract][Full Text] [Related]
7. Co-immobilization of glucose oxidase and hexokinase on silicate hybrid sol-gel membrane for glucose and ATP detections.
Liu S; Sun Y
Biosens Bioelectron; 2007 Jan; 22(6):905-11. PubMed ID: 16687247
[TBL] [Abstract][Full Text] [Related]
8. Mediator-free amperometric glucose biosensor based on glucose oxidase entrapped in poly(vinyl alcohol) matrix.
Guascito MR; Chirizzi D; Malitesta C; Mazzotta E
Analyst; 2011 Jan; 136(1):164-73. PubMed ID: 20877902
[TBL] [Abstract][Full Text] [Related]
9. Chemiluminescence flow-through biosensor for glucose with eggshell membrane as enzyme immobilization platform.
Li B; Lan D; Zhang Z
Anal Biochem; 2008 Mar; 374(1):64-70. PubMed ID: 18036547
[TBL] [Abstract][Full Text] [Related]
10. Development of glucose amperometric biosensor based on a novel attractive enzyme immobilization matrix: amino derivative of thiacalix[4]arene.
Chen M; Zhang W; Jiang R; Diao G
Anal Chim Acta; 2011 Feb; 687(2):177-83. PubMed ID: 21277420
[TBL] [Abstract][Full Text] [Related]
11. Amperometric glucose biosensor based on gold-deposited polyvinylferrocene film on Pt electrode.
Topçu Sulak M; Gökdoğan O; Gülce A; Gülce H
Biosens Bioelectron; 2006 Mar; 21(9):1719-26. PubMed ID: 16198102
[TBL] [Abstract][Full Text] [Related]
12. Direct electrochemistry of glucose oxidase immobilized on a hexagonal mesoporous silica-MCM-41 matrix.
Dai ZH; Ni J; Huang XH; Lu GF; Bao JC
Bioelectrochemistry; 2007 May; 70(2):250-6. PubMed ID: 17107826
[TBL] [Abstract][Full Text] [Related]
13. Amperometric glucose biosensor based on multilayer films via layer-by-layer self-assembly of multi-wall carbon nanotubes, gold nanoparticles and glucose oxidase on the Pt electrode.
Wu BY; Hou SH; Yin F; Zhao ZX; Wang YY; Wang XS; Chen Q
Biosens Bioelectron; 2007 Jun; 22(12):2854-60. PubMed ID: 17212983
[TBL] [Abstract][Full Text] [Related]
14. An amperometric glucose biosensor constructed by immobilizing glucose oxidase on titanium-containing mesoporous composite material of no. 41 modified screen-printed electrodes.
Dai Z; Fang M; Bao J; Wang H; Lu T
Anal Chim Acta; 2007 May; 591(2):195-9. PubMed ID: 17481408
[TBL] [Abstract][Full Text] [Related]
15. A novel glucose biosensor based on the immobilization of glucose oxidase onto gold nanoparticles-modified Pb nanowires.
Wang H; Wang X; Zhang X; Qin X; Zhao Z; Miao Z; Huang N; Chen Q
Biosens Bioelectron; 2009 Sep; 25(1):142-6. PubMed ID: 19595586
[TBL] [Abstract][Full Text] [Related]
16. Immobilization and direct electrochemistry of glucose oxidase on a tetragonal pyramid-shaped porous ZnO nanostructure for a glucose biosensor.
Dai Z; Shao G; Hong J; Bao J; Shen J
Biosens Bioelectron; 2009 Jan; 24(5):1286-91. PubMed ID: 18774704
[TBL] [Abstract][Full Text] [Related]
17. Application of polymaleimidostyrene as a convenient immobilization reagent of enzyme in biosensor.
Uchiyama S; Tomita R; Sekioka N; Imaizumi E; Hamana H; Hagiwara T
Bioelectrochemistry; 2006 May; 68(2):119-25. PubMed ID: 16039167
[TBL] [Abstract][Full Text] [Related]
18. Structure and biosensor characteristics of complex between glucose oxidase and plasma-polymerized nanothin film.
Muguruma H; Kase Y
Biosens Bioelectron; 2006 Dec; 22(5):737-43. PubMed ID: 16600587
[TBL] [Abstract][Full Text] [Related]
19. Problems in adapting a glucose-oxidase electrochemical sensor into an implantable glucose-sensing device.
Thévenot DR
Diabetes Care; 1982; 5(3):184-9. PubMed ID: 7172981
[No Abstract] [Full Text] [Related]
20. One-step immobilization of glucose oxidase in a silica matrix on a Pt electrode by an electrochemically induced sol-gel process.
Jia WZ; Wang K; Zhu ZJ; Song HT; Xia XH
Langmuir; 2007 Nov; 23(23):11896-900. PubMed ID: 17929847
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]