These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

211 related articles for article (PubMed ID: 15470925)

  • 21. A reusable OSL-film for 2D radiotherapy dosimetry.
    Wouter C; Dirk V; Paul L; Tom D
    Phys Med Biol; 2017 Oct; 62(21):8441-8454. PubMed ID: 29047456
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Image registration of BANG gel dose maps for quantitative dosimetry verification.
    Meeks SL; Bova FJ; Maryanski MJ; Kendrick LA; Ranade MK; Buatti JM; Friedman WA
    Int J Radiat Oncol Biol Phys; 1999 Mar; 43(5):1135-41. PubMed ID: 10192365
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry.
    MacDougall ND; Pitchford WG; Smith MA
    Phys Med Biol; 2002 Oct; 47(20):R107-21. PubMed ID: 12433119
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Linear energy transfer dependence of a normoxic polymer gel dosimeter investigated using proton beam absorbed dose measurements.
    Gustavsson H; Bäck SA; Medin J; Grusell E; Olsson LE
    Phys Med Biol; 2004 Sep; 49(17):3847-55. PubMed ID: 15470909
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Radiochromic film dosimetry with flatbed scanners: a fast and accurate method for dose calibration and uniformity correction with single film exposure.
    Menegotti L; Delana A; Martignano A
    Med Phys; 2008 Jul; 35(7):3078-85. PubMed ID: 18697531
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effects of phantom volume and shape on the accuracy of MRI BANG gel dosimetry using BANG3.
    MacDougall ND; Miquel ME; Keevil SF
    Br J Radiol; 2008 Jan; 81(961):46-50. PubMed ID: 17998279
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Calibration of GafChromic EBT3 for absorbed dose measurements in 5 MeV proton beam and (60)Co γ-rays.
    Vadrucci M; Esposito G; Ronsivalle C; Cherubini R; Marracino F; Montereali RM; Picardi L; Piccinini M; Pimpinella M; Vincenti MA; De Angelis C
    Med Phys; 2015 Aug; 42(8):4678-84. PubMed ID: 26233195
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The use of film dosimetry of the penumbra region to improve the accuracy of intensity modulated radiotherapy.
    Arnfield MR; Otto K; Aroumougame VR; Alkins RD
    Med Phys; 2005 Jan; 32(1):12-8. PubMed ID: 15719949
    [TBL] [Abstract][Full Text] [Related]  

  • 29. High-resolution dosimetry using radiochromic film and a document scanner.
    Stevens MA; Turner JR; Hugtenburg RP; Butler PH
    Phys Med Biol; 1996 Nov; 41(11):2357-65. PubMed ID: 8938031
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Dosimetry of therapeutic photon beams using an extended dose range film.
    Esthappan J; Mutic S; Harms WB; Dempsey JF; Low DA
    Med Phys; 2002 Oct; 29(10):2438-45. PubMed ID: 12408321
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Polymer gel dosimetry close to an 125I interstitial brachytherapy seed.
    Pantelis E; Lymperopoulou G; Papagiannis P; Sakelliou L; Stiliaris E; Sandilos P; Seimenis I; Kozicki M; Rosiak JM
    Phys Med Biol; 2005 Sep; 50(18):4371-84. PubMed ID: 16148399
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Polymer gel dosimetry on a multislice computed tomography scanner: effect of changing parameters on CTDI.
    Hill B; Venning AJ; Baldock C
    Phys Med; 2008 Sep; 24(3):149-58. PubMed ID: 18289906
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Evaluation of the dosimetric performance of BANG3 polymer gel.
    MacDougall ND; Miquel ME; Wilson DJ; Keevil SF; Smith MA
    Phys Med Biol; 2005 Apr; 50(8):1717-26. PubMed ID: 15815092
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Technical Note: Radiotherapy dose characterization of gel dosimetry using shear wave elasticity imaging.
    Xie WH; Su CT; Kao YJ; Chang TH; Chang YJ; Yao CH; Hsieh BY
    Med Phys; 2020 Mar; 47(3):1404-1410. PubMed ID: 31950500
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Characteristics of a new polymer gel for high-dose gradient dosimetry using a micro optical CT scanner.
    Massillon-JL G; Minniti R; Soares CG; Maryanski MJ; Robertson S
    Appl Radiat Isot; 2010 Jan; 68(1):144-54. PubMed ID: 19775899
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Polymer gel dosimetry.
    Baldock C; De Deene Y; Doran S; Ibbott G; Jirasek A; Lepage M; McAuley KB; Oldham M; Schreiner LJ
    Phys Med Biol; 2010 Mar; 55(5):R1-63. PubMed ID: 20150687
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Initial evaluation of commercial optical CT-based 3D gel dosimeter.
    Islam KT; Dempsey JF; Ranade MK; Maryanski MJ; Low DA
    Med Phys; 2003 Aug; 30(8):2159-68. PubMed ID: 12945982
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A prototype, glassless densitometer traceable to primary optical standards for quantitative radiochromic film dosimetry.
    Rosen BS; Soares CG; Hammer CG; Kunugi KA; DeWerd LA
    Med Phys; 2015 Jul; 42(7):4055-68. PubMed ID: 26133606
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The impact of the oxygen scavenger on the dose-rate dependence and dose sensitivity of MAGIC type polymer gels.
    Khan M; Heilemann G; Kuess P; Georg D; Berg A
    Phys Med Biol; 2018 Mar; 63(6):06NT01. PubMed ID: 29528035
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Validation of a precision radiochromic film dosimetry system for quantitative two-dimensional imaging of acute exposure dose distributions.
    Dempsey JF; Low DA; Mutic S; Markman J; Kirov AS; Nussbaum GH; Williamson JF
    Med Phys; 2000 Oct; 27(10):2462-75. PubMed ID: 11099217
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.