149 related articles for article (PubMed ID: 15473484)
1. 3-D simulation of the St. Jude Medical bileaflet valve opening process: fluid-structure interaction study and experimental validation.
Redaelli A; Bothorel H; Votta E; Soncini M; Morbiducci U; Del Gaudio C; Balducci A; Grigioni M
J Heart Valve Dis; 2004 Sep; 13(5):804-13. PubMed ID: 15473484
[TBL] [Abstract][Full Text] [Related]
2. Numerical simulation of opening process in a bileaflet mechanical heart valve under pulsatile flow condition.
Shi Y; Zhao Y; Yeo TJ; Hwang NH
J Heart Valve Dis; 2003 Mar; 12(2):245-55. PubMed ID: 12701798
[TBL] [Abstract][Full Text] [Related]
3. Numerical simulation of the dynamics of a bileaflet prosthetic heart valve using a fluid-structure interaction approach.
Nobili M; Morbiducci U; Ponzini R; Del Gaudio C; Balducci A; Grigioni M; Maria Montevecchi F; Redaelli A
J Biomech; 2008 Aug; 41(11):2539-50. PubMed ID: 18579146
[TBL] [Abstract][Full Text] [Related]
4. Computational fluid dynamics study of a protruded-hinge bileaflet mechanical heart valve.
Wang J; Yao H; Lim CJ; Zhao Y; Yeo TJ; Hwang NH
J Heart Valve Dis; 2001 Mar; 10(2):254-262; discussion 263. PubMed ID: 11297213
[TBL] [Abstract][Full Text] [Related]
5. Two-dimensional fluid-structure interaction simulation of bileaflet mechanical heart valve flow dynamics.
Cheng R; Lai YG; Chandran KB
J Heart Valve Dis; 2003 Nov; 12(6):772-80. PubMed ID: 14658820
[TBL] [Abstract][Full Text] [Related]
6. Dynamic impact stress analysis of a bileaflet mechanical heart valve.
Yuan Q; Xu L; Ngoi BK; Yeo TJ; Hwang NH
J Heart Valve Dis; 2003 Jan; 12(1):102-9. PubMed ID: 12578344
[TBL] [Abstract][Full Text] [Related]
7. Flow characterization of the ADVANTAGE and St. Jude Medical bileaflet mechanical heart valves.
Shu MC; O'Rourke KK; Coppin CM; Lemmon JD
J Heart Valve Dis; 2004 Sep; 13(5):814-22. PubMed ID: 15473485
[TBL] [Abstract][Full Text] [Related]
8. Evaluation technique for bileaflet mechanical valves.
Shipkowitz T; Ambrus J; Kurk J; Wickramasinghe K
J Heart Valve Dis; 2002 Mar; 11(2):275-82. PubMed ID: 12000172
[TBL] [Abstract][Full Text] [Related]
9. Predicting ATS Open Pivot heart valve performance with computational fluid dynamics.
Dumont K; Vierendeels JA; Segers P; Van Nooten GJ; Verdonck PR
J Heart Valve Dis; 2005 May; 14(3):393-9. PubMed ID: 15974535
[TBL] [Abstract][Full Text] [Related]
10. Asynchronous closure and leaflet impact velocity of bileaflet mechanical heart valves.
Wu ZJ; Hwang NH
J Heart Valve Dis; 1995 Jul; 4 Suppl 1():S38-49. PubMed ID: 8581210
[TBL] [Abstract][Full Text] [Related]
11. An integrated macro/micro approach to evaluating pivot flow within the Medtronic ADVANTAGE bileaflet mechanical heart valve.
Shu MC; Gross JM; O'Rourke KK; Yoganathan AP
J Heart Valve Dis; 2003 Jul; 12(4):503-12. PubMed ID: 12918854
[TBL] [Abstract][Full Text] [Related]
12. Numerical analysis on the hemodynamics and leaflet dynamics in a bileaflet mechanical heart valve using a fluid-structure interaction method.
Choi CR; Kim CN
ASAIO J; 2009; 55(5):428-37. PubMed ID: 19730001
[TBL] [Abstract][Full Text] [Related]
13. Comparison of the hemodynamic and thrombogenic performance of two bileaflet mechanical heart valves using a CFD/FSI model.
Dumont K; Vierendeels J; Kaminsky R; van Nooten G; Verdonck P; Bluestein D
J Biomech Eng; 2007 Aug; 129(4):558-65. PubMed ID: 17655477
[TBL] [Abstract][Full Text] [Related]
14. Particle image velocimetry investigation of intravalvular flow fields of a bileaflet mechanical heart valve in a pulsatile flow.
Subramanian A; Mu H; Kadambi JR; Wernet MP; Brendzel AM; Harasaki H
J Heart Valve Dis; 2000 Sep; 9(5):721-31. PubMed ID: 11041190
[TBL] [Abstract][Full Text] [Related]
15. A coupled fluid-structure finite element model of the aortic valve and root.
Nicosia MA; Cochran RP; Einstein DR; Rutland CJ; Kunzelman KS
J Heart Valve Dis; 2003 Nov; 12(6):781-9. PubMed ID: 14658821
[TBL] [Abstract][Full Text] [Related]
16. Closing behavior of a new bileaflet mechanical heart valve.
Bluestein D; Menon S; Wu ZJ; Haubold A; Armitage TL; Hwang NH
ASAIO J; 1993; 39(3):M398-402. PubMed ID: 8268566
[TBL] [Abstract][Full Text] [Related]
17. Dynamic simulation pericardial bioprosthetic heart valve function.
Kim H; Lu J; Sacks MS; Chandran KB
J Biomech Eng; 2006 Oct; 128(5):717-24. PubMed ID: 16995758
[TBL] [Abstract][Full Text] [Related]
18. Computational fluid dynamics simulation of transcatheter aortic valve degeneration.
Dwyer HA; Matthews PB; Azadani A; Jaussaud N; Ge L; Guy TS; Tseng EE
Interact Cardiovasc Thorac Surg; 2009 Aug; 9(2):301-8. PubMed ID: 19414489
[TBL] [Abstract][Full Text] [Related]
19. Two fluid-structure approaches for 3D simulation of St. Jude Medical bileaflet valve opening.
Nobili M; Passoni G; Redaelli A
J Appl Biomater Biomech; 2007; 5(1):49-59. PubMed ID: 20799197
[TBL] [Abstract][Full Text] [Related]
20. An experimental-computational analysis of MHV cavitation: effects of leaflet squeezing and rebound.
Makhijani VB; Yang HQ; Singhal AK; Hwang NH
J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S35-44; discussion S44-8. PubMed ID: 8061869
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]