BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

380 related articles for article (PubMed ID: 15474834)

  • 1. Capsulorhexis ovaling and capsular bag stretch after rigid and foldable intraocular lens implantation: experimental study in pediatric human eyes.
    Pandey SK; Werner L; Wilson ME; Izak AM; Apple DJ
    J Cataract Refract Surg; 2004 Oct; 30(10):2183-91. PubMed ID: 15474834
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Update on fixation of rigid and foldable posterior chamber intraocular lenses. Part II: Choosing the correct haptic fixation and intraocular lens design to help eradicate posterior capsule opacification.
    Ram J; Apple DJ; Peng Q; Visessook N; Auffarth GU; Schoderbek RJ; Ready EL
    Ophthalmology; 1999 May; 106(5):891-900. PubMed ID: 10328386
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Update on fixation of rigid and foldable posterior chamber intraocular lenses. Part I: Elimination of fixation-induced decentration to achieve precise optical correction and visual rehabilitation.
    Ram J; Apple DJ; Peng Q; Visessook N; Auffarth GU; Schoderbek RJ; Ready EL
    Ophthalmology; 1999 May; 106(5):883-90. PubMed ID: 10328385
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Configuration of the capsular sack after implantation of posterior chamber lenses].
    Legler UF; Assia EI; Apple DJ
    Ophthalmologe; 1993 Aug; 90(4):339-42. PubMed ID: 8374229
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A retrospective comparison of techniques to prevent secondary cataract formation following posterior chamber intraocular lens implantation in infants and children.
    Koch DD; Kohnen T
    Trans Am Ophthalmol Soc; 1997; 95():351-60; discussion 361-5. PubMed ID: 9440179
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fixation elements on plate intraocular lens: large positioning holes to improve security of capsular fixation.
    Whiteside SB; Apple DJ; Peng Q; Isaacs RT; Guindi A; Draughn RA
    Ophthalmology; 1998 May; 105(5):837-42. PubMed ID: 9593383
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Experimental study of different intraocular lens designs implanted in the bag after capsulorhexis.
    Tañá P; Belmonte J
    J Cataract Refract Surg; 1996 Nov; 22(9):1211-21. PubMed ID: 8972372
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Postoperative intraocular lens rotation: a randomized comparison of plate and loop haptic implants.
    Patel CK; Ormonde S; Rosen PH; Bron AJ
    Ophthalmology; 1999 Nov; 106(11):2190-5; discussion 2196. PubMed ID: 10571358
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Intraocular lens changes after short- and long-term exposure to intraocular silicone oil. An in vivo study.
    Khawly JA; Lambert RJ; Jaffe GJ
    Ophthalmology; 1998 Jul; 105(7):1227-33. PubMed ID: 9663226
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Change in capsulorhexis size with four foldable loop-haptic lenses over 6 months.
    Sickenberg M; Gonvers M; van Melle G
    J Cataract Refract Surg; 1998 Jul; 24(7):925-30. PubMed ID: 9682111
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Factors leading to lens implant decentration and exchange.
    Tappin MJ; Larkin DF
    Eye (Lond); 2000 Oct; 14 Pt 5():773-6. PubMed ID: 11116703
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Quantification of capsular sack forces after intraocular lens implantation].
    Effert R; Heim T; Danassis M
    Fortschr Ophthalmol; 1990; 87(6):579-82. PubMed ID: 2086398
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Anterior capsule opacification: a histopathological study comparing different IOL styles.
    Werner L; Pandey SK; Escobar-Gomez M; Visessook N; Peng Q; Apple DJ
    Ophthalmology; 2000 Mar; 107(3):463-71. PubMed ID: 10711882
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ideal size of an intraocular lens for capsular bag fixation.
    Lim SJ; Kang SJ; Kim HB; Apple DJ
    J Cataract Refract Surg; 1998 Mar; 24(3):397-402. PubMed ID: 9559478
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Decentration of 3-piece versus plate-haptic silicone intraocular lenses.
    Hwang IP; Clinch TE; Moshifar M; Malmquist L; Cason M; Crandall AS
    J Cataract Refract Surg; 1998 Nov; 24(11):1505-8. PubMed ID: 9818342
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Lens position following planned capsular sac fixation: results of 200 consecutively surgically treated phacoemulsifications].
    Duncker G; Wetzel W
    Fortschr Ophthalmol; 1990; 87(2):140-3. PubMed ID: 2358269
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Mini-haptics to improve capsular fixation of plate-haptic silicone intraocular lenses.
    Kent DG; Peng Q; Isaacs RT; Whiteside SB; Barker DL; Apple DJ
    J Cataract Refract Surg; 1998 May; 24(5):666-71. PubMed ID: 9610451
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Posterior continuous curvilinear capsulorhexis in congenital cataract with opaque posterior capsule].
    Liu Y; Li S
    Zhonghua Yan Ke Za Zhi; 1997 May; 33(3):189-91. PubMed ID: 10437032
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Morphology of capsular sack retraction in relation to capsulotomy technique, lens design and sulcus-/saccus fixation].
    Hartmann C; Krieglstein GK
    Klin Monbl Augenheilkd; 1990 Oct; 197(4):302-10. PubMed ID: 2280565
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Silicone one piece intraocular implant and anterior capsule fibrosis].
    Auer C; Gonvers M
    Klin Monbl Augenheilkd; 1995 May; 206(5):293-5. PubMed ID: 7609368
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 19.