These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

259 related articles for article (PubMed ID: 15475844)

  • 21. Nailing versus plating for comminuted fractures of the distal femur: a comparative biomechanical in vitro study of three implants.
    Mehling I; Hoehle P; Sternstein W; Blum J; Rommens PM
    Eur J Trauma Emerg Surg; 2013 Apr; 39(2):139-46. PubMed ID: 26815070
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comparative finite element analysis of three implants fixing stable and unstable subtrochanteric femoral fractures: Proximal Femoral Nail Antirotation (PFNA), Proximal Femoral Locking Plate (PFLP), and Reverse Less Invasive Stabilization System (LISS).
    Wang J; Ma JX; Lu B; Bai HH; Wang Y; Ma XL
    Orthop Traumatol Surg Res; 2020 Feb; 106(1):95-101. PubMed ID: 31345739
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Mechanical comparison of a distal femoral side plate and a retrograde intramedullary nail.
    Meyer RW; Plaxton NA; Postak PD; Gilmore A; Froimson MI; Greenwald AS
    J Orthop Trauma; 2000 Aug; 14(6):398-404. PubMed ID: 11001413
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Biomechanical comparison of blade plate and intramedullary nail fixation for tibiocalcaneal arthrodesis.
    Lee AT; Sundberg EB; Lindsey DP; Harris AH; Chou LB
    Foot Ankle Int; 2010 Feb; 31(2):164-71. PubMed ID: 20132755
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Is augmented LISS plating biomechanically advantageous over conventional LISS plating in unstable osteoporotic distal femoral fractures?
    Todorov D; Zderic I; Richards RG; Lenz M; Knobe M; Enchev D; Baltov A; Gueorguiev B; Stoffel K
    J Orthop Res; 2018 Oct; 36(10):2604-2611. PubMed ID: 29748964
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The Retrograde Tibial Nail: presentation and biomechanical evaluation of a new concept in the treatment of distal tibia fractures.
    Kuhn S; Appelmann P; Pairon P; Mehler D; Rommens PM
    Injury; 2014 Jan; 45 Suppl 1():S81-6. PubMed ID: 24225228
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A biomechanical comparison of locked plate fixation with percutaneous insertion capability versus the angled blade plate in a subtrochanteric fracture gap model.
    Crist BD; Khalafi A; Hazelwood SJ; Lee MA
    J Orthop Trauma; 2009 Oct; 23(9):622-7. PubMed ID: 19897982
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Combination of anatomical locking plate and retrograde intramedullary nail in distal femoral fractures: comparison of mechanical stability.
    Başcı O; Karakaşlı A; Kumtepe E; Güran O; Havıtçıoğlu H
    Eklem Hastalik Cerrahisi; 2015; 26(1):21-6. PubMed ID: 25741916
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Distal femoral fixation: a biomechanical comparison of trigen retrograde intramedullary (i.m.) nail, dynamic condylar screw (DCS), and locking compression plate (LCP) condylar plate.
    Heiney JP; Barnett MD; Vrabec GA; Schoenfeld AJ; Baji A; Njus GO
    J Trauma; 2009 Feb; 66(2):443-9. PubMed ID: 19204519
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Finite element comparison of retrograde intramedullary nailing and locking plate fixation with/without an intramedullary allograft for distal femur fracture following total knee arthroplasty.
    Chen SH; Chiang MC; Hung CH; Lin SC; Chang HW
    Knee; 2014 Jan; 21(1):224-31. PubMed ID: 23582376
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Biomechanical analysis of distal femur fracture fixation: fixed-angle screw-plate construct versus condylar blade plate.
    Higgins TF; Pittman G; Hines J; Bachus KN
    J Orthop Trauma; 2007 Jan; 21(1):43-6. PubMed ID: 17211268
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Long Segment Blocking Screws Increase the Stability of Retrograde Nail Fixation in Geriatric Supracondylar Femur Fractures: Eliminating the "Bell-Clapper Effect".
    Auston D; Donohue D; Stoops K; Cox J; Diaz M; Santoni B; Mir H
    J Orthop Trauma; 2018 Nov; 32(11):559-564. PubMed ID: 30086037
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Effect of Implant Linkage on Axial and Rotational Stiffness of Nail-Plate Constructs for Comminuted Distal Femoral Fractures.
    Lin CC; Parody N; Anil U; Egol KA
    J Orthop Trauma; 2023 Jul; 37(7):351-355. PubMed ID: 36862986
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Cement augmentation of the proximal femoral nail antirotation for the treatment of osteoporotic pertrochanteric fractures--a biomechanical cadaver study.
    Fensky F; Nüchtern JV; Kolb JP; Huber S; Rupprecht M; Jauch SY; Sellenschloh K; Püschel K; Morlock MM; Rueger JM; Lehmann W
    Injury; 2013 Jun; 44(6):802-7. PubMed ID: 23545113
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Biomechanical evaluation of retrograde docking nailing to a total hip arthroplasty stem in a periprosthetic femur fracture model.
    Lenz M; Hofmann-Fliri L; Kasper LA; Varga P; Zderic I; Gehweiler D; Klos K; Hofmann GO; Stoffel K; Gueorguiev B
    Injury; 2021 Jan; 52(1):53-59. PubMed ID: 33129493
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Finite element analysis of different medial fixation strategies in double-plate osteosynthesis for AO type 33-C2 Femoral fractures.
    Li M; Jiang Y; Wang J; Xu G; Wang D; Li J; Zhang W
    Injury; 2023 Apr; 54 Suppl 2():S86-S94. PubMed ID: 35219538
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Locked minimally invasive plating versus fourth generation nailing in the treatment of AO/OTA 31A2.2 fractures: A biomechanical comparison of PCCP(®) and Intertan nail(®).
    Knobe M; Gradl G; Buecking B; Gackstatter S; Sönmez TT; Ghassemi A; Stromps JP; Prescher A; Pape HC
    Injury; 2015 Aug; 46(8):1475-82. PubMed ID: 25997559
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Modified fixations for distal femur fractures following total knee arthroplasty: a biomechanical and clinical relevance study.
    Chen SH; Tai CL; Yu TC; Wang CW; Lin CW; Chen CY; Liu KC
    Knee Surg Sports Traumatol Arthrosc; 2016 Oct; 24(10):3262-3271. PubMed ID: 27056688
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Biomechanical evaluation of the docking nail concept in periprosthetic fracture fixation around a stemmed total knee arthroplasty.
    Lenz M; Acklin YP; Kasper LA; Mischler D; Varga P; Zderic I; Gehweiler D; Klos K; Gueorguiev B; Stoffel K
    J Biomech; 2021 Jan; 115():110109. PubMed ID: 33257010
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Retrograde tibial nailing: a minimally invasive and biomechanically superior alternative to angle-stable plate osteosynthesis in distal tibia fractures.
    Kuhn S; Appelmann P; Mehler D; Pairon P; Rommens PM
    J Orthop Surg Res; 2014 May; 9():35. PubMed ID: 24886667
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.