These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 15480936)

  • 1. Syncope: a clinically guided diagnostic algorithm.
    Kaufmann H; Wieling W
    Clin Auton Res; 2004 Oct; 14 Suppl 1():87-90. PubMed ID: 15480936
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Value and limitations of noninvasive assessment of syncope.
    Hammill SC
    Cardiol Clin; 1997 May; 15(2):195-218. PubMed ID: 9164710
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The use of monitoring strategies in patients with unexplained syncope--role of the external and implantable loop recorder.
    Krahn AD; Klein GJ; Yee R; Skanes AC
    Clin Auton Res; 2004 Oct; 14 Suppl 1():55-61. PubMed ID: 15480931
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Evaluation of "complex syncope: what are the indications for second-level investigations?].
    Ungar A; Morrione A; Rafanelli M; Maraviglia A; Landi A; Caldi F; Chisciotti VM; Ruffolo E; Marchionni N; Del Rosso A
    G Ital Cardiol (Rome); 2009 Jan; 10(1):6-17. PubMed ID: 19292015
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Syncope and a negative electrophysiological study. The usefulness of an implantable Holter monitor for the diagnosis of ventricular arrhythmias].
    Belchí Navarro J; Quesada Dorador A; Atienza Fernández F; Villalba Caballero SJ; Roda Nicolás J; de Velasco Ramí JA
    Rev Esp Cardiol; 1999 Dec; 52(12):1151-3. PubMed ID: 10659662
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Use of the implantable loop recorder in evaluation of patients with unexplained syncope.
    Krahn AD; Klein GJ; Skanes AC; Yee R
    J Cardiovasc Electrophysiol; 2003 Sep; 14(9 Suppl):S70-3. PubMed ID: 12950523
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Current investigation and management of patients with syncope: results of the European Heart Rhythm Association survey.
    Dagres N; Bongiorni MG; Dobreanu D; Madrid A; Svendsen JH; Blomström-Lundqvist C;
    Europace; 2013 Dec; 15(12):1812-5. PubMed ID: 24280765
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The application of a standardized strategy of evaluation in patients with syncope referred to three syncope units.
    Croci F; Brignole M; Alboni P; Menozzi C; Raviele A; Del Rosso A; Dinelli M; Solano A; Bottoni N; Donateo P
    Europace; 2002 Oct; 4(4):351-5. PubMed ID: 12408252
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Significance of diagnostic methods in the work-up of syncope].
    Strotmann C; Rüb N; Wolpert C
    Herzschrittmacherther Elektrophysiol; 2011 Jun; 22(2):72-82. PubMed ID: 21562861
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Syncope: Approaches to Diagnosis and Management.
    Palaniswamy C; Aronow WS; Agrawal N; Balasubramaniyam N; Lakshmanadoss U
    Am J Ther; 2016; 23(1):e208-17. PubMed ID: 22960849
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [The implantable loop recorder].
    Graf D; Roussianos MO; Schlaepfer J; Forclaz A; Zerm T; Metzger J; Fromer M; Pruvot E
    Rev Med Suisse; 2007 Dec; 3(138):2914-8. PubMed ID: 18277768
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Insertable loop recorder use for detection of intermittent arrhythmias.
    Krahn AD; Klein GJ; Skanes AC; Yee R
    Pacing Clin Electrophysiol; 2004 May; 27(5):657-64. PubMed ID: 15125724
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Assessment of a standardized algorithm for cardiac pacing in older patients affected by severe unpredictable reflex syncopes.
    Brignole M; Ammirati F; Arabia F; Quartieri F; Tomaino M; Ungar A; Lunati M; Russo V; Del Rosso A; Gaggioli G;
    Eur Heart J; 2015 Jun; 36(24):1529-35. PubMed ID: 25825044
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Clinical laboratory testing: what is the role of tilt-table testing, active standing test, carotid massage, electrophysiological testing and ATP test in the syncope evaluation?
    Blanc JJ
    Prog Cardiovasc Dis; 2013; 55(4):418-24. PubMed ID: 23472780
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Subcutaneous electrocardiographic loop recorder in the investigation of syncope].
    Eskola M; Yli-Mäyry S
    Duodecim; 2001; 117(4):407-14. PubMed ID: 12092383
    [No Abstract]   [Full Text] [Related]  

  • 16. Prolonged implantable electrocardiographic monitoring indicates a high rate of misdiagnosis of epilepsy--REVISE study.
    Petkar S; Hamid T; Iddon P; Clifford A; Rice N; Claire R; McKee D; Curtis N; Cooper PN; Fitzpatrick AP
    Europace; 2012 Nov; 14(11):1653-60. PubMed ID: 22753867
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Use of an extended monitoring strategy in patients with problematic syncope. Reveal Investigators.
    Krahn AD; Klein GJ; Yee R; Takle-Newhouse T; Norris C
    Circulation; 1999 Jan; 99(3):406-10. PubMed ID: 9918528
    [TBL] [Abstract][Full Text] [Related]  

  • 18. ECG monitoring in syncope.
    Ruwald MH; Zareba W
    Prog Cardiovasc Dis; 2013; 56(2):203-10. PubMed ID: 24215752
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The Cost-Effective Evaluation of Syncope.
    Angus S
    Med Clin North Am; 2016 Sep; 100(5):1019-32. PubMed ID: 27542422
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Catecholaminergic polymorphic ventricular tachycardia detected by an insertable loop recorder in a pediatric patient with exercise syncopal episodes.
    Ormaetxe JM; Sáez R; Arkotxa MF; Martinez-Alday JD
    Pediatr Cardiol; 2004; 25(6):693-5. PubMed ID: 15185051
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.