These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 15483803)

  • 1. The use of bilobed porous-coated acetabular components without structural bone graft for type III acetabular defects in revision total hip arthroplasty: a prospective study with a minimum 2-year follow-up.
    Moskal JT; Shen FH
    J Arthroplasty; 2004 Oct; 19(7):867-73. PubMed ID: 15483803
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Type III acetabular defect revision with bilobed components: five-year results.
    Moskal JT; Higgins ME; Shen J
    Clin Orthop Relat Res; 2008 Mar; 466(3):691-5. PubMed ID: 18264858
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Harris-Galante porous-coated acetabular component with screw fixation. An average ten-year follow-up study.
    Clohisy JC; Harris WH
    J Bone Joint Surg Am; 1999 Jan; 81(1):66-73. PubMed ID: 9973056
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Medial protrusio technique for placement of a porous-coated, hemispherical acetabular component without cement in a total hip arthroplasty in patients who have acetabular dysplasia.
    Dorr LD; Tawakkol S; Moorthy M; Long W; Wan Z
    J Bone Joint Surg Am; 1999 Jan; 81(1):83-92. PubMed ID: 9973058
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Revision Total Hip Arthroplasty for Paprosky Type III Acetabular Defect With Structural Allograft and Tantalum Trabecular Metal Acetabular Cup.
    Chang CH; Hu CC; Chen CC; Mahajan J; Chang Y; Shih HN; Kwon YM
    Orthopedics; 2018 Nov; 41(6):e861-e867. PubMed ID: 30371922
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reconstruction of acetabular defects with porous tantalum shells and augments in revision total hip arthroplasty at ten-year follow-up.
    Löchel J; Janz V; Hipfl C; Perka C; Wassilew GI
    Bone Joint J; 2019 Mar; 101-B(3):311-316. PubMed ID: 30813786
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Porous-ingrowth revision acetabular implants secured with peripheral screws. A minimum twelve-year follow-up.
    Weeden SH; Paprosky WG
    J Bone Joint Surg Am; 2006 Jun; 88(6):1266-71. PubMed ID: 16757760
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Acetabular revision with use of a bilobed component inserted without cement in patients who have acetabular bone-stock deficiency.
    Chen WM; Engh CA; Hopper RH; McAuley JP; Engh CA
    J Bone Joint Surg Am; 2000 Feb; 82(2):197-206. PubMed ID: 10682728
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Use of porous tantalum components in Paprosky two and three acetabular revision. A minimum five-year follow-up of fifty one hips.
    Flecher X; Appy B; Parratte S; Ollivier M; Argenson JN
    Int Orthop; 2017 May; 41(5):911-916. PubMed ID: 27766385
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Revision Total Hip Arthroplasty Using a Cementless Cup Supporter and Iliac Autograft: A Minimum of 15-Year Follow-Up.
    Yoshino K; Tsukeoka T; Tsuneizumi Y; Lee TH; Nakamura J; Suzuki M; Ohtori S
    J Arthroplasty; 2017 Nov; 32(11):3495-3501. PubMed ID: 28697865
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Revision Total Hip Arthroplasty Using an Acetabular Reinforcement Ring With a Hook: A Precise Follow-Up, at Average 11.4 Years, of a Previous Report.
    Park KS; Seon JK; Lee KB; Kim SK; Chan CK; Yoon TR
    J Arthroplasty; 2017 Feb; 32(2):503-509. PubMed ID: 27546473
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement. An average ten-year follow-up study.
    Clohisy JC; Harris WH
    J Bone Joint Surg Am; 1999 Feb; 81(2):247-55. PubMed ID: 10073588
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Structural Allograft Supporting a Trabecular Metal Cup Provides Durable Results in Complex Revision Arthroplasty.
    Prieto HA; Kralovec ME; Berry DJ; Trousdale RT; Sierra RJ; Cabanela ME
    J Arthroplasty; 2017 Nov; 32(11):3488-3494. PubMed ID: 28662954
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Minimum Five-Year Outcomes with Porous Tantalum Acetabular Cup and Augment Construct in Complex Revision Total Hip Arthroplasty.
    Jenkins DR; Odland AN; Sierra RJ; Hanssen AD; Lewallen DG
    J Bone Joint Surg Am; 2017 May; 99(10):e49. PubMed ID: 28509833
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Treatment of type III acetabular deficiencies in revision total hip arthroplasty without structural bone-graft.
    Sutherland CJ
    J Arthroplasty; 1996 Jan; 11(1):91-8. PubMed ID: 8676125
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Outcome of porous tantalum acetabular components for Paprosky type 3 and 4 acetabular defects.
    Batuyong ED; Brock HS; Thiruvengadam N; Maloney WJ; Goodman SB; Huddleston JI
    J Arthroplasty; 2014 Jun; 29(6):1318-22. PubMed ID: 24405625
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cementless acetabular revision for aseptic failure of cemented hip arthroplasty.
    Chareancholvanich K; Tanchuling A; Seki T; Gustilo RB
    Clin Orthop Relat Res; 1999 Apr; (361):140-9. PubMed ID: 10212607
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Revision of the acetabulum with a contemporary cementless component.
    Wysocki RW; Della Valle CJ; Shott S; Rosenberg AG; Berger RA; Galante JO
    J Arthroplasty; 2009 Sep; 24(6 Suppl):58-63. PubMed ID: 19282138
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Revision of the acetabular component without cement after a previous acetabular reconstruction with use of a bulk femoral head graft in patients who had congenital dislocation or dysplasia. A follow-up note.
    Bal BS; Maurer T; Harris WH
    J Bone Joint Surg Am; 1999 Dec; 81(12):1703-6. PubMed ID: 10608381
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Porous-coated cementless acetabular components without bulk bone graft in revision surgery.
    Ito H; Tanino H; Yamanaka Y; Sato T; Minami A; Matsuno T
    J Arthroplasty; 2010 Dec; 25(8):1307-10. PubMed ID: 20022452
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.