BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

1444 related articles for article (PubMed ID: 15485564)

  • 1. The use of a circular external skeletal fixation device for the management of long bone osteotomies in large ruminants: an experimental study.
    Aithal HP; Singh GR; Hoque M; Maiti SK; Kinjavdekar P; Pawde AM; Setia HC;
    J Vet Med A Physiol Pathol Clin Med; 2004 Aug; 51(6):284-93. PubMed ID: 15485564
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Closed reduction and type-II external fixation of comminuted fractures of the radius and tibia in dogs: 23 cases (1990-1994).
    Johnson AL; Seitz SE; Smith CW; Johnson JM; Schaeffer DJ
    J Am Vet Med Assoc; 1996 Oct; 209(8):1445-8. PubMed ID: 8870743
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Use of a circular external skeletal fixator to treat comminuted metacarpal and tibial fractures in six calves.
    Bilgili H; Kurum B; Captug O
    Vet Rec; 2008 Dec; 163(23):683-7. PubMed ID: 19060317
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Type-II external fixation, using new clamps and positive-profile threaded pins, for treatment of fractures of the radius and tibia in dogs.
    Kraus KH; Wotton HM; Boudrieau RJ; Schwarz L; Diamond D; Minihan A
    J Am Vet Med Assoc; 1998 Apr; 212(8):1267-70. PubMed ID: 9569167
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Unifocal internal and external bone lengthening with circular external skeletal fixator in 5 dogs.
    Captug O; Bilgili H; Kurum B
    Pol J Vet Sci; 2008; 11(2):159-73. PubMed ID: 18683547
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Management of tibial fractures using a circular external fixator in two calves.
    Aithal HP; Kinjavdekar P; Amarpal ; Pawde AM; Singh GR; Setia HC
    Vet Surg; 2010 Jul; 39(5):621-6. PubMed ID: 20636557
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Treatment of radius-ulna and tibia fractures with circular external skeletal fixator in 19 dogs.
    Bilgili H; Kurum B; Captug O
    Pol J Vet Sci; 2007; 10(4):217-31. PubMed ID: 18198537
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of two dynamic axial fixators for large ruminants.
    Singh GR; Aithal HP; Amarpal ; Kinjavdekar P; Maiti SK; Hoque M; Pawde AM; Joshi HC
    Vet Surg; 2007 Jan; 36(1):88-97. PubMed ID: 17214826
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Management of 49 antebrachial and crural fractures in dogs using circular external fixators.
    Rovesti GL; Bosio A; Marcellin-Little DJ
    J Small Anim Pract; 2007 Apr; 48(4):194-200. PubMed ID: 17381764
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Open reduction and bone plate stabilization, compared with closed reduction and external fixation, for treatment of comminuted tibial fractures: 47 cases (1980-1995) in dogs.
    Dudley M; Johnson AL; Olmstead M; Smith CW; Schaeffer DJ; Abbuehl U
    J Am Vet Med Assoc; 1997 Oct; 211(8):1008-12. PubMed ID: 9343545
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Management of tibial fractures with Orthofix axial external skeletal fixator in 15 dogs.
    Gül NY; Yanik K
    Vet Comp Orthop Traumatol; 2006; 19(4):228-35. PubMed ID: 17143395
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Treatment of distal diaphyseal fractures using hybrid external skeletal fixation in three dogs.
    Clarke SP; Carmichael S
    J Small Anim Pract; 2006 Feb; 47(2):98-103. PubMed ID: 16438698
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Management of fractures of the long bones of eight cats using external skeletal fixation and a tied-in intra-medullary pin with a resin-acrylic bar.
    Worth AJ
    N Z Vet J; 2007 Aug; 55(4):191-7. PubMed ID: 17676085
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [External fixation in fractures of the lower limb in children].
    Siguier T; Glorion C; Langlais J; Rouvreau P; Pouliquen JC
    Rev Chir Orthop Reparatrice Appar Mot; 1995; 81(2):157-62. PubMed ID: 7569191
    [TBL] [Abstract][Full Text] [Related]  

  • 15. External fixation of tibial pilon fractures and fracture healing.
    Ristiniemi J
    Acta Orthop Suppl; 2007 Jun; 78(326):3, 5-34. PubMed ID: 17465283
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biomechanical comparison of a circular external skeletal fixator construct to pin and tension band wire fixation for the stabilization of olecranon osteotomies in dogs: a cadaveric study.
    Halling KB; Lewis DD; Cross AR; Sammy RJ; Rapoff AJ
    Vet Surg; 2003; 32(4):324-35. PubMed ID: 12865994
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hybrid external fixation of distal tibial fractures: new strategy to place pins and wires without penetrating the anterior compartment.
    Oh JK; Lee JJ; Jung DY; Kim BJ; Oh CW
    Arch Orthop Trauma Surg; 2004 Oct; 124(8):542-6. PubMed ID: 15340748
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mechanical performance of Ilizarov circular external fixators in comparison with other external fixators.
    Podolsky A; Chao EY
    Clin Orthop Relat Res; 1993 Aug; (293):61-70. PubMed ID: 8339510
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Mechanical evaluation of transosseous wire rope configurations in a large animal external fixator.
    Rapoff AJ; Markel MD; Vanderby R
    Am J Vet Res; 1995 May; 56(5):694-9. PubMed ID: 7661467
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Clinical study of a new design multifunction dynamic external fixator system for bone reconstructions.
    Suksathien Y; Suksathien R
    J Med Assoc Thai; 2011 Oct; 94(10):1224-9. PubMed ID: 22145508
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 73.