189 related articles for article (PubMed ID: 15486531)
1. Renal disease: value of functional magnetic resonance imaging with flow and perfusion measurements.
Michaely HJ; Schoenberg SO; Ittrich C; Dikow R; Bock M; Guenther M
Invest Radiol; 2004 Nov; 39(11):698-705. PubMed ID: 15486531
[TBL] [Abstract][Full Text] [Related]
2. Volumetric Arterial Spin-labeled Perfusion Imaging of the Kidneys with a Three-dimensional Fast Spin Echo Acquisition.
Robson PM; Madhuranthakam AJ; Smith MP; Sun MR; Dai W; Rofsky NM; Pedrosa I; Alsop DC
Acad Radiol; 2016 Feb; 23(2):144-54. PubMed ID: 26521186
[TBL] [Abstract][Full Text] [Related]
3. Comprehensive MR evaluation of renal disease: added clinical value of quantified renal perfusion values over single MR angiography.
Attenberger UI; Sourbron SP; Schoenberg SO; Morelli J; Leiner T; Schoeppler GM; Samtleben W; Birkemeier KL; Glaser C; Reiser MF; Michaely HJ
J Magn Reson Imaging; 2010 Jan; 31(1):125-33. PubMed ID: 20027580
[TBL] [Abstract][Full Text] [Related]
4. Can MR measurement of renal artery flow and renal volume predict the outcome of percutaneous transluminal renal angioplasty?
Binkert CA; Debatin JF; Schneider E; Hodler J; Ruehm SG; Schmidt M; Hoffmann U
Cardiovasc Intervent Radiol; 2001; 24(4):233-9. PubMed ID: 11779012
[TBL] [Abstract][Full Text] [Related]
5. Phase-contrast magnetic resonance flow quantification in renal arteries: comparison with 133Xenon washout measurements.
de Haan MW; van Engelshoven JM; Houben AJ; Kaandorp DW; Kessels AG; Kroon AA; de Leeuw PW
Hypertension; 2003 Jan; 41(1):114-8. PubMed ID: 12511539
[TBL] [Abstract][Full Text] [Related]
6. [Diagnosis of renal artery stenosis with magnetic resonance angiography and stenosis quantification].
Marchand B; Hernandez-Hoyos M; Orkisz M; Douek P
J Mal Vasc; 2000 Dec; 25(5):312-320. PubMed ID: 11148391
[TBL] [Abstract][Full Text] [Related]
7. Correlation of biexponential diffusion parameters with arterial spin-labeling perfusion MRI: results in transplanted kidneys.
Heusch P; Wittsack HJ; Heusner T; Buchbender C; Quang MN; Martirosian P; Bilk P; Kröpil P; Blondin D; Antoch G; Lanzman RS
Invest Radiol; 2013 Mar; 48(3):140-4. PubMed ID: 23249648
[TBL] [Abstract][Full Text] [Related]
8. Inter-study reproducibility of arterial spin labelling magnetic resonance imaging for measurement of renal perfusion in healthy volunteers at 3 Tesla.
Gillis KA; McComb C; Foster JE; Taylor AH; Patel RK; Morris ST; Jardine AG; Schneider MP; Roditi GH; Delles C; Mark PB
BMC Nephrol; 2014 Jan; 15():23. PubMed ID: 24484613
[TBL] [Abstract][Full Text] [Related]
9. Cine-ASL: a steady-pulsed arterial spin labeling method for myocardial perfusion mapping in mice. Part I. Experimental study.
Troalen T; Capron T; Cozzone PJ; Bernard M; Kober F
Magn Reson Med; 2013 Nov; 70(5):1389-98. PubMed ID: 23283821
[TBL] [Abstract][Full Text] [Related]
10. Interleaved gradient echo planar (IGEPI) and phase contrast CINE-PC flow measurements in the renal artery.
Bock M; Schoenberg SO; Schad LR; Knopp MV; Essig M; van Kaick G
J Magn Reson Imaging; 1998; 8(4):889-95. PubMed ID: 9702891
[TBL] [Abstract][Full Text] [Related]
11. Diagnostic value of renal perfusion in patients with chronic kidney disease using 3D arterial spin labeling.
Cai YZ; Li ZC; Zuo PL; Pfeuffer J; Li YM; Liu F; Liu RB
J Magn Reson Imaging; 2017 Aug; 46(2):589-594. PubMed ID: 28181335
[TBL] [Abstract][Full Text] [Related]
12. Quantitative single breath-hold renal arterial spin labeling imaging at 7T.
Li X; Auerbach EJ; Van de Moortele PF; Ugurbil K; Metzger GJ
Magn Reson Med; 2018 Feb; 79(2):815-825. PubMed ID: 28488274
[TBL] [Abstract][Full Text] [Related]
13. Quantification of renal perfusion abnormalities using an intravascular contrast agent (part 2): results in animals and humans with renal artery stenosis.
Schoenberg SO; Aumann S; Just A; Bock M; Knopp MV; Johansson LO; Ahlstrom H
Magn Reson Med; 2003 Feb; 49(2):288-98. PubMed ID: 12541249
[TBL] [Abstract][Full Text] [Related]
14. Robust kidney perfusion mapping in pediatric chronic kidney disease using single-shot 3D-GRASE ASL with optimized retrospective motion correction.
Nery F; De Vita E; Clark CA; Gordon I; Thomas DL
Magn Reson Med; 2019 May; 81(5):2972-2984. PubMed ID: 30536817
[TBL] [Abstract][Full Text] [Related]
15. Arterial spin labeling MRI for assessment of perfusion in native and transplanted kidneys.
Artz NS; Sadowski EA; Wentland AL; Grist TM; Seo S; Djamali A; Fain SB
Magn Reson Imaging; 2011 Jan; 29(1):74-82. PubMed ID: 20850241
[TBL] [Abstract][Full Text] [Related]
16. Breath-hold ultrafast three-dimensional gadolinium-enhanced MR angiography of the aorta and the renal and other visceral abdominal arteries.
Holland GA; Dougherty L; Carpenter JP; Golden MA; Gilfeather M; Slossman F; Schnall MD; Axel L
AJR Am J Roentgenol; 1996 Apr; 166(4):971-81. PubMed ID: 8610584
[TBL] [Abstract][Full Text] [Related]
17. A feasibility study on model-based evaluation of kidney perfusion measured by means of FAIR prepared true-FISP arterial spin labeling (ASL) on a 3-T MR scanner.
Kiefer C; Schroth G; Gralla J; Diehm N; Baumgartner I; Husmann M
Acad Radiol; 2009 Jan; 16(1):79-87. PubMed ID: 19064215
[TBL] [Abstract][Full Text] [Related]
18. Perfusion MR imaging with FAIR true FISP spin labeling in patients with and without renal artery stenosis: initial experience.
Fenchel M; Martirosian P; Langanke J; Giersch J; Miller S; Stauder NI; Kramer U; Claussen CD; Schick F
Radiology; 2006 Mar; 238(3):1013-21. PubMed ID: 16439565
[TBL] [Abstract][Full Text] [Related]
19. Functional evaluation of transplanted kidneys using arterial spin labeling MRI.
Heusch P; Wittsack HJ; Blondin D; Ljimani A; Nguyen-Quang M; Martirosian P; Zenginli H; Bilk P; Kröpil P; Heusner TA; Antoch G; Lanzman RS
J Magn Reson Imaging; 2014 Jul; 40(1):84-9. PubMed ID: 24123319
[TBL] [Abstract][Full Text] [Related]
20. High-resolution mouse kidney perfusion imaging by pseudo-continuous arterial spin labeling at 11.75T.
Duhamel G; Prevost V; Girard OM; Callot V; Cozzone PJ
Magn Reson Med; 2014 Mar; 71(3):1186-96. PubMed ID: 23568817
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]