These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

189 related articles for article (PubMed ID: 15486531)

  • 41. Saturated multi-delay renal arterial spin labeling technique for simultaneous perfusion and T
    Ning Z; Chen S; Chen Z; Han H; Qiao H; Zhang N; Wang R; Shen R; Zhao X
    Magn Reson Med; 2022 Sep; 88(3):1055-1067. PubMed ID: 35506512
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Renal arterial stenosis: prospective comparison of color Doppler US and breath-hold, three-dimensional, dynamic, gadolinium-enhanced MR angiography.
    De Cobelli F; Venturini M; Vanzulli A; Sironi S; Salvioni M; Angeli E; Scifo P; Garancini MP; Quartagno R; Bianchi G; Del Maschio A
    Radiology; 2000 Feb; 214(2):373-80. PubMed ID: 10671583
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Renal MR angiography at 1.0 T: three-dimensional (3D) phase-contrast techniques versus gadolinium-enhanced 3D fast low-angle shot breath-hold imaging.
    Hahn U; Miller S; Nägele T; Schick F; Erdtmann B; Duda S; Claussen CD
    AJR Am J Roentgenol; 1999 Jun; 172(6):1501-8. PubMed ID: 10350280
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Diagnosis of congenital obstructive aortic arch anomalies in Chinese children by contrast-enhanced magnetic resonance angiography.
    Ming Z; Yumin Z; Yuhua L; Biao J; Aimin S; Qian W
    J Cardiovasc Magn Reson; 2006; 8(5):747-53. PubMed ID: 16891235
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Noninvasive measurement of renal blood flow by magnetic resonance imaging in rats.
    Romero CA; Cabral G; Knight RA; Ding G; Peterson EL; Carretero OA
    Am J Physiol Renal Physiol; 2018 Jan; 314(1):F99-F106. PubMed ID: 28978533
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Renal perfusion: comparison of saturation-recovery TurboFLASH measurements at 1.5T with saturation-recovery TurboFLASH and time-resolved echo-shared angiographic technique (TREAT) at 3.0T.
    Michaely HJ; Nael K; Schoenberg SO; Finn JP; Oesingmann N; Lodemann KP; Reiser MF; Ruehm SG
    J Magn Reson Imaging; 2006 Dec; 24(6):1413-9. PubMed ID: 17051532
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Functional magnetic resonance imaging in renal artery stenosis.
    Schoenberg SO; Rieger JR; Michaely HJ; Rupprecht H; Samtleben W; Reiser MF
    Abdom Imaging; 2006; 31(2):200-12. PubMed ID: 16317490
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Consistency of Multiple Renal Functional MRI Measurements Over 18 Months.
    Li LP; Thacker J; Li W; Tan H; Wang C; Kohn O; Sprague S; Prasad P
    J Magn Reson Imaging; 2018 Aug; 48(2):514-521. PubMed ID: 29517835
    [TBL] [Abstract][Full Text] [Related]  

  • 49. [Myocardial microcirculation in humans--new approaches using MRI].
    Wacker CM; Bauer WR
    Herz; 2003 Mar; 28(2):74-81. PubMed ID: 12669220
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Coronary artery disease: myocardial perfusion MR imaging with sensitivity encoding versus conventional angiography.
    Plein S; Radjenovic A; Ridgway JP; Barmby D; Greenwood JP; Ball SG; Sivananthan MU
    Radiology; 2005 May; 235(2):423-30. PubMed ID: 15858084
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Hemodynamic effects of furosemide on renal perfusion as evaluated by ASL-MRI.
    Wang J; Zhang Y; Yang X; Wang X; Zhang J; Fang J; Jiang X
    Acad Radiol; 2012 Oct; 19(10):1194-200. PubMed ID: 22958717
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Contrast-enhanced three-dimensional fast spoiled gradient-echo renal MR imaging: evaluation of vascular and nonvascular disease.
    Heiss SG; Shifrin RY; Sommer FG
    Radiographics; 2000; 20(5):1341-52; discussion 1353-4. PubMed ID: 10992022
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Fast imaging strategies for mouse kidney perfusion measurement with pseudocontinuous arterial spin labeling (pCASL) at ultra high magnetic field (11.75 tesla).
    Prevost VH; Girard OM; Callot V; Cozzone PJ; Duhamel G
    J Magn Reson Imaging; 2015 Oct; 42(4):999-1008. PubMed ID: 25712197
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Renal artery stenosis and accessory renal arteries: accuracy of detection and visualization with gadolinium-enhanced breath-hold MR angiography.
    Bakker J; Beek FJ; Beutler JJ; Hene RJ; de Kort GA; de Lange EE; Moons KG; Mali WP
    Radiology; 1998 May; 207(2):497-504. PubMed ID: 9577501
    [TBL] [Abstract][Full Text] [Related]  

  • 55. High resolution MR perfusion imaging of the kidneys at 3 Tesla without administration of contrast media.
    Boss A; Martirosian P; Graf H; Claussen CD; Schlemmer HP; Schick F
    Rofo; 2005 Dec; 177(12):1625-30. PubMed ID: 16333784
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Optimization of non-contrast-enhanced MR angiography of the renal artery with three-dimensional balanced steady-state free-precession and time-spatial labeling inversion pulse (time-SLIP) at 3T MRI, in relation to age and blood velocity.
    Kurata Y; Kido A; Fujimoto K; Kiguchi K; Takakura K; Moribata Y; Shitano F; Himoto Y; Fushimi Y; Okada T; Togashi K
    Abdom Radiol (NY); 2016 Jan; 41(1):119-26. PubMed ID: 26830618
    [TBL] [Abstract][Full Text] [Related]  

  • 57. [Time-resolved MR angiography of the renal artery: morphology and perfusion].
    Krause UJ; Pabst T; Köstler H; Helbig C; Kenn W; Hahn D
    Rofo; 2002 Sep; 174(9):1170-4. PubMed ID: 12221578
    [TBL] [Abstract][Full Text] [Related]  

  • 58. ECG-gated nonenhanced 3D steady-state free precession MR angiography in assessment of transplant renal arteries: comparison with DSA.
    Lanzman RS; Voiculescu A; Walther C; Ringelstein A; Bi X; Schmitt P; Freitag SM; Won S; Scherer A; Blondin D
    Radiology; 2009 Sep; 252(3):914-21. PubMed ID: 19635833
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Dynamic pulmonary perfusion and flow quantification with MR imaging, 3.0T vs. 1.5T: initial results.
    Nael K; Michaely HJ; Lee M; Goldin J; Laub G; Finn JP
    J Magn Reson Imaging; 2006 Aug; 24(2):333-9. PubMed ID: 16786566
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Nonenhanced renal MR angiography using steady-state free precession (SSFP) and time-spatial labeling inversion pulse (Time-SLIP): repeatability and comparison of different tagging location.
    Zhang Y; Xing Z; Liu Y; She D; Zeng Z; Cao D
    Abdom Imaging; 2014 Oct; 39(5):1000-8. PubMed ID: 24687245
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.