These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 15488228)

  • 1. Accuracy and stability of temperature probes for intracranial application.
    Alessandri B; Hoelper BM; Behr R; Kempski O
    J Neurosci Methods; 2004 Oct; 139(2):161-5. PubMed ID: 15488228
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Brain tissue oxygen monitoring: a study of in vitro accuracy and stability of Neurovent-PTO and Licox sensors.
    Purins K; Enblad P; Sandhagen B; Lewén A
    Acta Neurochir (Wien); 2010 Apr; 152(4):681-8. PubMed ID: 19826757
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Brain oxygen monitoring: in-vitro accuracy, long-term drift and response-time of Licox- and Neurotrend sensors.
    Hoelper BM; Alessandri B; Heimann A; Behr R; Kempski O
    Acta Neurochir (Wien); 2005 Jul; 147(7):767-74; discussion 774. PubMed ID: 15889319
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinical evaluation of a new multiparameter neuromonitoring device: measurement of brain tissue oxygen, brain temperature, and intracranial pressure.
    Huschak G; Hoell T; Hohaus C; Kern C; Minkus Y; Meisel HJ
    J Neurosurg Anesthesiol; 2009 Apr; 21(2):155-60. PubMed ID: 19295395
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Brain temperature measurement: A study of in vitro accuracy and stability of smart catheter temperature sensors.
    Li C; Wu PM; Wu Z; Ahn CH; LeDoux D; Shutter LA; Hartings JA; Narayan RK
    Biomed Microdevices; 2012 Feb; 14(1):109-18. PubMed ID: 21952982
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Temperature measurement: comparison of non-invasive methods used in adult critical care.
    Farnell S; Maxwell L; Tan S; Rhodes A; Philips B
    J Clin Nurs; 2005 May; 14(5):632-9. PubMed ID: 15840078
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparing mercury-in-glass, tympanic and disposable thermometers in measuring body temperature in healthy young people.
    Khorshid L; Eşer I; Zaybak A; Yapucu U
    J Clin Nurs; 2005 Apr; 14(4):496-500. PubMed ID: 15807757
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The new Licox combined brain tissue oxygen and brain temperature monitor: assessment of in vitro accuracy and clinical experience in severe traumatic brain injury.
    Stewart C; Haitsma I; Zador Z; Hemphill JC; Morabito D; Manley G; Rosenthal G
    Neurosurgery; 2008 Dec; 63(6):1159-64; discussion 1164-5. PubMed ID: 19057329
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of temperature readings from a percutaneous thermal sensing microchip with temperature readings from a digital rectal thermometer in equids.
    Robinson TR; Hussey SB; Hill AE; Heckendorf CC; Stricklin JB; Traub-Dargatz JL
    J Am Vet Med Assoc; 2008 Aug; 233(4):613-7. PubMed ID: 18710319
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Validity and reliability of temperature measurement by heat flow thermistors, flexible thermocouple probes and thermistors in a stirred water bath.
    Versey NG; Gore CJ; Halson SL; Plowman JS; Dawson BT
    Physiol Meas; 2011 Sep; 32(9):1417-24. PubMed ID: 21788687
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Acceptable agreement between tympanic and rectal temperature in acute stroke patients.
    Christensen H; Boysen G
    Int J Clin Pract; 2002 Mar; 56(2):82-4. PubMed ID: 11926710
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Accuracy and precision of noninvasive temperature measurement in adult intensive care patients.
    Lawson L; Bridges EJ; Ballou I; Eraker R; Greco S; Shively J; Sochulak V
    Am J Crit Care; 2007 Sep; 16(5):485-96. PubMed ID: 17724246
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Noninvasive monitoring of brain temperature during mild hypothermia.
    Weis J; Covaciu L; Rubertsson S; Allers M; Lunderquist A; Ahlström H
    Magn Reson Imaging; 2009 Sep; 27(7):923-32. PubMed ID: 19282122
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Use of modified infrared aural canal thermometers during cardiac surgery].
    Kawamura A; Matsukawa T; Ozaki M; Okuyama K; Ohkawa I; Kumazawa T
    Masui; 2000 Jul; 49(7):792-5. PubMed ID: 10933038
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Calibration of an ingestible temperature sensor.
    Hunt AP; Stewart IB
    Physiol Meas; 2008 Nov; 29(11):N71-8. PubMed ID: 18843163
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A systematic performance evaluation of brain and body temperature sensors using ultra-stable temperature references.
    Machin G; Childs C
    J Med Eng Technol; 2010 Apr; 34(3):192-9. PubMed ID: 20059431
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A simple method for accurate temperature measurement.
    Grucza R; Boruta E
    Acta Physiol Pol; 1980; 31(4):449-52. PubMed ID: 7446155
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Reliability of an infrared forehead skin thermometer for core temperature measurements.
    Kistemaker JA; Den Hartog EA; Daanen HA
    J Med Eng Technol; 2006; 30(4):252-61. PubMed ID: 16864237
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measurement accuracy of fever by tympanic and axillary thermometry.
    Devrim I; Kara A; Ceyhan M; Tezer H; Uludağ AK; Cengiz AB; Yiğitkanl I; Seçmeer G
    Pediatr Emerg Care; 2007 Jan; 23(1):16-9. PubMed ID: 17228215
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of three methods of temperature measurement in hypothermic, euthermic, and hyperthermic dogs.
    Greer RJ; Cohn LA; Dodam JR; Wagner-Mann CC; Mann FA
    J Am Vet Med Assoc; 2007 Jun; 230(12):1841-8. PubMed ID: 17571987
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.