BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

449 related articles for article (PubMed ID: 15498896)

  • 21. The effect of different adaptation strengths on image quality and radiation dose using Siemens Care Dose 4D.
    Söderberg M; Gunnarsson M
    Radiat Prot Dosimetry; 2010; 139(1-3):173-9. PubMed ID: 20231163
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comparative study of image quality for MSCT and CBCT scanners for dentomaxillofacial radiology applications.
    Loubele M; Maes F; Jacobs R; van Steenberghe D; White SC; Suetens P
    Radiat Prot Dosimetry; 2008; 129(1-3):222-6. PubMed ID: 18583372
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Automatic Tube Potential Selection with Tube Current Modulation (APSCM) in coronary CT angiography: Comparison of image quality and radiation dose with conventional body mass index-based protocol.
    Park YJ; Kim YJ; Lee JW; Kim HY; Hong YJ; Lee HJ; Hur J; Nam JE; Choi BW
    J Cardiovasc Comput Tomogr; 2012; 6(3):184-90. PubMed ID: 22551594
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis.
    Rizzo S; Kalra M; Schmidt B; Dalal T; Suess C; Flohr T; Blake M; Saini S
    AJR Am J Roentgenol; 2006 Mar; 186(3):673-9. PubMed ID: 16498094
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Multi-detector row CT: principles and practice for abdominal applications.
    Saini S
    Radiology; 2004 Nov; 233(2):323-7. PubMed ID: 15459326
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Radiation dose and image quality in pediatric CT: effect of technical factors and phantom size and shape.
    Siegel MJ; Schmidt B; Bradley D; Suess C; Hildebolt C
    Radiology; 2004 Nov; 233(2):515-22. PubMed ID: 15358847
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Dose reduction in spiral-CT: detection of pulmonary coin lesions with and without anatomically adjusted modulation of tube current].
    Greess H; Baum U; Wolf H; Lell M; Nömayr A; Schmidt B; Kalender WA; Bautz W
    Rofo; 2001 May; 173(5):466-70. PubMed ID: 11414157
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [CT: status on multi-detector row scanners!!!].
    Martinez-Souloumiac L; Gosso F
    J Radiol; 2006; 87(7-8):927-35. PubMed ID: 16888584
    [No Abstract]   [Full Text] [Related]  

  • 29. Multi-detector row CT: radiation dose characteristics.
    Hamberg LM; Rhea JT; Hunter GJ; Thrall JH
    Radiology; 2003 Mar; 226(3):762-72. PubMed ID: 12616020
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Dose performance of a 64-channel dual-source CT scanner.
    McCollough CH; Primak AN; Saba O; Bruder H; Stierstorfer K; Raupach R; Suess C; Schmidt B; Ohnesorge BM; Flohr TG
    Radiology; 2007 Jun; 243(3):775-84. PubMed ID: 17446525
    [TBL] [Abstract][Full Text] [Related]  

  • 31. CT dose optimization when changing to CT multi-detector row technology.
    Verdun FR; Gutierrez D; Schnyder P; Aroua A; Bochud F; Gudinchet F
    Curr Probl Diagn Radiol; 2007; 36(4):176-84. PubMed ID: 17601537
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Survey of conventional and spiral ct doses.
    Hidajat N; Wolf M; Nunnemann A; Liersch P; Gebauer B; Teichgräber U; Schröder RJ; Felix R
    Radiology; 2001 Feb; 218(2):395-401. PubMed ID: 11161152
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Relationships between patient size, dose and image noise under automatic tube current modulation systems.
    Sookpeng S; Martin CJ; Gentle DJ; Lopez-Gonzalez MR
    J Radiol Prot; 2014 Mar; 34(1):103-23. PubMed ID: 24334678
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Technical principles of dual source CT.
    Petersilka M; Bruder H; Krauss B; Stierstorfer K; Flohr TG
    Eur J Radiol; 2008 Dec; 68(3):362-8. PubMed ID: 18842371
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Effect of x-ray tube parameters and iodine concentration on image quality and radiation dose in cerebral pediatric and adult CT angiography: a phantom study.
    Papadakis AE; Perisinakis K; Raissaki M; Damilakis J
    Invest Radiol; 2013 Apr; 48(4):192-9. PubMed ID: 23344518
    [TBL] [Abstract][Full Text] [Related]  

  • 36. C-arm cone-beam CT: general principles and technical considerations for use in interventional radiology.
    Orth RC; Wallace MJ; Kuo MD;
    J Vasc Interv Radiol; 2008 Jun; 19(6):814-20. PubMed ID: 18503894
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Image noise and radiation dose using an automatic tube current modulation technique at 64-detector computed tomography: effect of off-center patient position, bowtie filter type, and scan projection radiograph.
    Funama Y; Taguchi K; Awai K; Sakabe D; Shimamura M; Yamashita Y
    J Comput Assist Tomogr; 2009; 33(6):973-7. PubMed ID: 19940670
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Efficient use of automatic exposure control systems in computed tomography requires correct patient positioning.
    Gudjonsdottir J; Svensson JR; Campling S; Brennan PC; Jonsdottir B
    Acta Radiol; 2009 Nov; 50(9):1035-41. PubMed ID: 19863414
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Optimal use of AEC in CT: a literature review.
    Gudjónsdóttir J; Ween B; Olsen DR
    Radiol Technol; 2010; 81(4):309-17. PubMed ID: 20207787
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Relating noise to image quality indicators in CT examinations with tube current modulation.
    Solomon JB; Li X; Samei E
    AJR Am J Roentgenol; 2013 Mar; 200(3):592-600. PubMed ID: 23436849
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 23.