These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

74 related articles for article (PubMed ID: 15508152)

  • 1. Perfusion assessment with bolus differentiation: a technique applicable to hyperpolarized tracers.
    Johansson E; Olsson LE; Månsson S; Petersson JS; Golman K; Ståhlberg F; Wirestam R
    Magn Reson Med; 2004 Nov; 52(5):1043-51. PubMed ID: 15508152
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Cerebral perfusion assessment by bolus tracking using hyperpolarized 13C.
    Johansson E; Månsson S; Wirestam R; Svensson J; Petersson JS; Golman K; Ståhlberg F
    Magn Reson Med; 2004 Mar; 51(3):464-72. PubMed ID: 15004786
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Absolute quantification of regional renal blood flow in swine by dynamic contrast-enhanced magnetic resonance imaging using a blood pool contrast agent.
    Lüdemann L; Nafz B; Elsner F; Grosse-Siestrup C; Meissler M; Kaufels N; Rehbein H; Persson PB; Michaely HJ; Lengsfeld P; Voth M; Gutberlet M
    Invest Radiol; 2009 Mar; 44(3):125-34. PubMed ID: 19151609
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A randomized, controlled, double-blind crossover study on the effects of 1-L infusions of 6% hydroxyethyl starch suspended in 0.9% saline (voluven) and a balanced solution (Plasma Volume Redibag) on blood volume, renal blood flow velocity, and renal cortical tissue perfusion in healthy volunteers.
    Chowdhury AH; Cox EF; Francis ST; Lobo DN
    Ann Surg; 2014 May; 259(5):881-7. PubMed ID: 24253140
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantification of renal perfusion: comparison of arterial spin labeling and dynamic contrast-enhanced MRI.
    Winter JD; St Lawrence KS; Cheng HL
    J Magn Reson Imaging; 2011 Sep; 34(3):608-15. PubMed ID: 21761490
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Noninvasive measurement of absolute renal perfusion by contrast medium-enhanced magnetic resonance imaging.
    Montet X; Ivancevic MK; Belenger J; Jorge-Costa M; Pochon S; Pechère A; Terrier F; Vallée JP
    Invest Radiol; 2003 Sep; 38(9):584-92. PubMed ID: 12960528
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hyperpolarized 13C MRI of the pulmonary vasculature and parenchyma.
    Ishii M; Emami K; Kadlecek S; Petersson JS; Golman K; Vahdat V; Yu J; Cadman RV; MacDuffie-Woodburn J; Stephen M; Lipson DA; Rizi RR
    Magn Reson Med; 2007 Mar; 57(3):459-63. PubMed ID: 17326170
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Myocardial microcirculation in humans--new approaches using MRI].
    Wacker CM; Bauer WR
    Herz; 2003 Mar; 28(2):74-81. PubMed ID: 12669220
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hyperpolarized agents for advanced MRI investigations.
    Viale A; Reineri F; Santelia D; Cerutti E; Ellena S; Gobetto R; Aime S
    Q J Nucl Med Mol Imaging; 2009 Dec; 53(6):604-17. PubMed ID: 20016452
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Perfusion imaging of the rat kidney with MR.
    Williams DS; Zhang W; Koretsky AP; Adler S
    Radiology; 1994 Mar; 190(3):813-8. PubMed ID: 8115632
    [TBL] [Abstract][Full Text] [Related]  

  • 11. High resolution MR perfusion imaging of the kidneys at 3 Tesla without administration of contrast media.
    Boss A; Martirosian P; Graf H; Claussen CD; Schlemmer HP; Schick F
    Rofo; 2005 Dec; 177(12):1625-30. PubMed ID: 16333784
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Arterial transit time imaging with flow encoding arterial spin tagging (FEAST).
    Wang J; Alsop DC; Song HK; Maldjian JA; Tang K; Salvucci AE; Detre JA
    Magn Reson Med; 2003 Sep; 50(3):599-607. PubMed ID: 12939768
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Examination of self-navigating MR-sequences for perfusion imaging of the kidneys].
    Lietzmann F; Zöllner FG; Michaely HJ; Schad LR
    Z Med Phys; 2010; 20(2):124-33. PubMed ID: 20807690
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Quantification of renal perfusion and function on a voxel-by-voxel basis: a feasibility study.
    Dujardin M; Sourbron S; Luypaert R; Verbeelen D; Stadnik T
    Magn Reson Med; 2005 Oct; 54(4):841-9. PubMed ID: 16155888
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quantification of blood flow in brain tumors: comparison of arterial spin labeling and dynamic susceptibility-weighted contrast-enhanced MR imaging.
    Warmuth C; Gunther M; Zimmer C
    Radiology; 2003 Aug; 228(2):523-32. PubMed ID: 12819338
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Bolus delay and dispersion in perfusion MRI: implications for tissue predictor models in stroke.
    Calamante F; Willats L; Gadian DG; Connelly A
    Magn Reson Med; 2006 May; 55(5):1180-5. PubMed ID: 16598717
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Arterial spin labeling blood flow magnetic resonance imaging for evaluation of renal injury.
    Liu YP; Song R; Liang Ch; Chen X; Liu B
    Am J Physiol Renal Physiol; 2012 Aug; 303(4):F551-8. PubMed ID: 22647631
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Iterative blind deconvolution in magnetic resonance brain perfusion imaging.
    Grüner R; Taxt T
    Magn Reson Med; 2006 Apr; 55(4):805-15. PubMed ID: 16526016
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optimization of fast spiral chemical shift imaging using least squares reconstruction: application for hyperpolarized (13)C metabolic imaging.
    Levin YS; Mayer D; Yen YF; Hurd RE; Spielman DM
    Magn Reson Med; 2007 Aug; 58(2):245-52. PubMed ID: 17654596
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Quantification of cerebral arterial blood volume using arterial spin labeling with intravoxel incoherent motion-sensitive gradients.
    Kim T; Kim SG
    Magn Reson Med; 2006 May; 55(5):1047-57. PubMed ID: 16596632
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.