  • 1. Critical bending moment of implant-abutment screw joint interfaces: effect of torque levels and implant diameter.
    Tan BF; Tan KB; Nicholls JI
    Int J Oral Maxillofac Implants; 2004; 19(5):648-58. PubMed ID: 15508980
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Critical bending moment of four implant-abutment interface designs.
    Lee FK; Tan KB; Nicholls JI
    Int J Oral Maxillofac Implants; 2010; 25(4):744-51. PubMed ID: 20657869
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Implant-abutment screw joint preload of 7 hex-top abutment systems.
    Tan KB; Nicholls JI
    Int J Oral Maxillofac Implants; 2001; 16(3):367-77. PubMed ID: 11432656
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dynamic fatigue properties of the dental implant-abutment interface: joint opening in wide-diameter versus standard-diameter hex-type implants.
    Hoyer SA; Stanford CM; Buranadham S; Fridrich T; Wagner J; Gratton D
    J Prosthet Dent; 2001 Jun; 85(6):599-607. PubMed ID: 11404760
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Load fatigue performance of implant-ceramic abutment combinations.
    Nguyen HQ; Tan KB; Nicholls JI
    Int J Oral Maxillofac Implants; 2009; 24(4):636-46. PubMed ID: 19885403
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Implant abutment screw rotations and preloads for four different screw materials and surfaces.
    Martin WC; Woody RD; Miller BH; Miller AW
    J Prosthet Dent; 2001 Jul; 86(1):24-32. PubMed ID: 11458261
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Load fatigue performance of four implant-abutment interface designs: effect of torque level and implant system.
    Quek HC; Tan KB; Nicholls JI
    Int J Oral Maxillofac Implants; 2008; 23(2):253-62. PubMed ID: 18548921
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The dynamic natures of implant loading.
    Wang RF; Kang B; Lang LA; Razzoog ME
    J Prosthet Dent; 2009 Jun; 101(6):359-71. PubMed ID: 19463663
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In vitro study of the influence of the type of connection on the fracture load of zirconia abutments with internal and external implant-abutment connections.
    Sailer I; Sailer T; Stawarczyk B; Jung RE; Hämmerle CH
    Int J Oral Maxillofac Implants; 2009; 24(5):850-8. PubMed ID: 19865625
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Probabilistic analysis of preload in the abutment screw of a dental implant complex.
    Guda T; Ross TA; Lang LA; Millwater HR
    J Prosthet Dent; 2008 Sep; 100(3):183-93. PubMed ID: 18762030
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Preloads generated with repeated tightening in three types of screws used in dental implant assemblies.
    Byrne D; Jacobs S; O'Connell B; Houston F; Claffey N
    J Prosthodont; 2006; 15(3):164-71. PubMed ID: 16681498
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effect of repeated torque in small diameter implants with machined and premachined abutments.
    Saboury A; Neshandar Asli H; Vaziri S
    Clin Implant Dent Relat Res; 2012 May; 14 Suppl 1():e224-30. PubMed ID: 22376004
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Load fatigue performance of two implant-abutment combinations.
    Basten CH; Nicholls JI; Daly CH; Taggart R
    Int J Oral Maxillofac Implants; 1996; 11(4):522-8. PubMed ID: 8803348
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Load fatigue performance of a single-tooth implant abutment system: effect of diameter.
    Quek CE; Tan KB; Nicholls JI
    Int J Oral Maxillofac Implants; 2006; 21(6):929-36. PubMed ID: 17190303
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Axial displacement of abutments into implants and implant replicas, with the tapered cone-screw internal connection, as a function of tightening torque.
    Dailey B; Jordan L; Blind O; Tavernier B
    Int J Oral Maxillofac Implants; 2009; 24(2):251-6. PubMed ID: 19492640
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of the ITI Morse taper implant/abutment design with an internal modification.
    Ding TA; Woody RD; Higginbottom FL; Miller BH
    Int J Oral Maxillofac Implants; 2003; 18(6):865-72. PubMed ID: 14696662
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Examination of the implant-abutment interface after fatigue testing.
    Cibirka RM; Nelson SK; Lang BR; Rueggeberg FA
    J Prosthet Dent; 2001 Mar; 85(3):268-75. PubMed ID: 11264934
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Reverse torque failure of screw-shaped implants in baboons: baseline data for abutment torque application.
    Carr AB; Larsen PE; Papazoglou E; McGlumphy E
    Int J Oral Maxillofac Implants; 1995; 10(2):167-74. PubMed ID: 7744435
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of the effect of retightening and mechanical cycling on preload maintenance of retention screws.
    Delben JA; Gomes EA; Barão VA; Assunção WG
    Int J Oral Maxillofac Implants; 2011; 26(2):251-6. PubMed ID: 21483877
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Abutment rotational displacement of external hexagon implant system under lateral cyclic loading.
    Khraisat A; Baqain ZH; Smadi L; Nomura S; Miyakawa O; Elnasser Z
    Clin Implant Dent Relat Res; 2006; 8(2):96-9. PubMed ID: 16774595
    [TBL] [Abstract][Full Text] [Related]  