246 related articles for article (PubMed ID: 15509066)
1. Performance measurements of a depth-encoding PET detector module based on position-sensitive avalanche photodiode read-out.
Dokhale PA; Silverman RW; Shah KS; Grazioso R; Farrell R; Glodo J; McClish MA; Entine G; Tran VH; Cherry SR
Phys Med Biol; 2004 Sep; 49(18):4293-304. PubMed ID: 15509066
[TBL] [Abstract][Full Text] [Related]
2. Lutetium oxyorthosilicate block detector readout by avalanche photodiode arrays for high resolution animal PET.
Pichler BJ; Swann BK; Rochelle J; Nutt RE; Cherry SR; Siegel SB
Phys Med Biol; 2004 Sep; 49(18):4305-19. PubMed ID: 15509067
[TBL] [Abstract][Full Text] [Related]
3. Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodes.
Yang Y; Dokhale PA; Silverman RW; Shah KS; McClish MA; Farrell R; Entine G; Cherry SR
Phys Med Biol; 2006 May; 51(9):2131-42. PubMed ID: 16625031
[TBL] [Abstract][Full Text] [Related]
4. Effects of system geometry and other physical factors on photon sensitivity of high-resolution positron emission tomography.
Habte F; Foudray AM; Olcott PD; Levin CS
Phys Med Biol; 2007 Jul; 52(13):3753-72. PubMed ID: 17664575
[TBL] [Abstract][Full Text] [Related]
5. Development of depth encoding small animal PET detectors using dual-ended readout of pixelated scintillator arrays with SiPMs.
Kuang Z; Sang Z; Wang X; Fu X; Ren N; Zhang X; Zheng Y; Yang Q; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y
Med Phys; 2018 Feb; 45(2):613-621. PubMed ID: 29222959
[TBL] [Abstract][Full Text] [Related]
6. Performance of long rectangular semi-monolithic scintillator PET detectors.
Zhang X; Wang X; Ren N; Hu B; Ding B; Kuang Z; Wu S; Sang Z; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y
Med Phys; 2019 Apr; 46(4):1608-1619. PubMed ID: 30723932
[TBL] [Abstract][Full Text] [Related]
7. A prototype PET scanner with DOI-encoding detectors.
Yang Y; Wu Y; Qi J; St James S; Du H; Dokhale PA; Shah KS; Farrell R; Cherry SR
J Nucl Med; 2008 Jul; 49(7):1132-40. PubMed ID: 18552140
[TBL] [Abstract][Full Text] [Related]
8. High-Resolution Depth-Encoding PET Detector Module with Prismatoid Light-Guide Array.
LaBella A; Cao X; Petersen E; Lubinsky R; Biegon A; Zhao W; Goldan AH
J Nucl Med; 2020 Oct; 61(10):1528-1533. PubMed ID: 32111684
[TBL] [Abstract][Full Text] [Related]
9. Effects of reflector and crystal surface on the performance of a depth-encoding PET detector with dual-ended readout.
Ren S; Yang Y; Cherry SR
Med Phys; 2014 Jul; 41(7):072503. PubMed ID: 24989406
[TBL] [Abstract][Full Text] [Related]
10. Signal and noise properties of position-sensitive avalanche photodiodes.
Yang Y; Wu Y; Farrell R; Dokhale PA; Shah KS; Cherry SR
Phys Med Biol; 2011 Oct; 56(19):6327-36. PubMed ID: 21896961
[TBL] [Abstract][Full Text] [Related]
11. Development of a novel depth of interaction PET detector using highly multiplexed G-APD cross-strip encoding.
Kolb A; Parl C; Mantlik F; Liu CC; Lorenz E; Renker D; Pichler BJ
Med Phys; 2014 Aug; 41(8):081916. PubMed ID: 25086547
[TBL] [Abstract][Full Text] [Related]
12. Experimental characterization and system simulations of depth of interaction PET detectors using 0.5 mm and 0.7 mm LSO arrays.
James SS; Yang Y; Wu Y; Farrell R; Dokhale P; Shah KS; Cherry SR
Phys Med Biol; 2009 Jul; 54(14):4605-19. PubMed ID: 19567945
[TBL] [Abstract][Full Text] [Related]
13. Depth of interaction calibration for PET detectors with dual-ended readout by PSAPDs.
Yang Y; Qi J; Wu Y; St James S; Farrell R; Dokhale PA; Shah KS; Cherry SR
Phys Med Biol; 2009 Jan; 54(2):433-45. PubMed ID: 19098356
[TBL] [Abstract][Full Text] [Related]
14. Investigation of single, random, and true counts from natural radioactivity in LSO-based clinical PET.
Yamamoto S; Horii H; Hurutani M; Matsumoto K; Senda M
Ann Nucl Med; 2005 Apr; 19(2):109-14. PubMed ID: 15909490
[TBL] [Abstract][Full Text] [Related]
15. Timing properties of phosphor-coated polished LSO crystals.
Schmall JP; Roncali E; Berg E; Viswanath V; Du J; Cherry SR
Phys Med Biol; 2014 Aug; 59(15):N139-51. PubMed ID: 25047008
[TBL] [Abstract][Full Text] [Related]
16. Tapered LSO arrays for small animal PET.
Yang Y; James SS; Wu Y; Du H; Qi J; Farrell R; Dokhale PA; Shah KS; Vaigneur K; Cherry SR
Phys Med Biol; 2011 Jan; 56(1):139-53. PubMed ID: 21119228
[TBL] [Abstract][Full Text] [Related]
17. Monte Carlo simulations of compact gamma cameras based on avalanche photodiodes.
Després P; Funk T; Shah KS; Hasegawa BH
Phys Med Biol; 2007 Jun; 52(11):3057-74. PubMed ID: 17505089
[TBL] [Abstract][Full Text] [Related]
18. A Prototype High-Resolution Small-Animal PET Scanner Dedicated to Mouse Brain Imaging.
Yang Y; Bec J; Zhou J; Zhang M; Judenhofer MS; Bai X; Di K; Wu Y; Rodriguez M; Dokhale P; Shah KS; Farrell R; Qi J; Cherry SR
J Nucl Med; 2016 Jul; 57(7):1130-5. PubMed ID: 27013696
[TBL] [Abstract][Full Text] [Related]
19. A sub-millimeter resolution PET detector module using a multi-pixel photon counter array.
Song TY; Wu H; Komarov S; Siegel SB; Tai YC
Phys Med Biol; 2010 May; 55(9):2573-87. PubMed ID: 20393236
[TBL] [Abstract][Full Text] [Related]
20. Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner.
Catana C; Wu Y; Judenhofer MS; Qi J; Pichler BJ; Cherry SR
J Nucl Med; 2006 Dec; 47(12):1968-76. PubMed ID: 17138739
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]