These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
170 related articles for article (PubMed ID: 15527994)
1. Imaging of a mixture of hyperpolarized 3He and 129Xe. Acosta RH; Blümler P; Han S; Appelt S; Häsing FW; Schmiedeskamp J; Heil W; Spiess HW Magn Reson Imaging; 2004 Oct; 22(8):1077-83. PubMed ID: 15527994 [TBL] [Abstract][Full Text] [Related]
2. Hyperpolarized 3He and 129Xe MR imaging in healthy volunteers and patients with chronic obstructive pulmonary disease. Kirby M; Svenningsen S; Owrangi A; Wheatley A; Farag A; Ouriadov A; Santyr GE; Etemad-Rezai R; Coxson HO; McCormack DG; Parraga G Radiology; 2012 Nov; 265(2):600-10. PubMed ID: 22952383 [TBL] [Abstract][Full Text] [Related]
3. Development of hyperpolarized noble gas MRI. Albert MS; Balamore D Nucl Instrum Methods Phys Res A; 1998; 402():441-53. PubMed ID: 11543065 [TBL] [Abstract][Full Text] [Related]
4. Hyperpolarized 129 Xe MRI of the mouse lung at a low xenon concentration using a continuous flow-type hyperpolarizing system. Wakayama T; Kitamoto M; Ueyama T; Imai H; Narazaki M; Kimura A; Fujiwara H J Magn Reson Imaging; 2008 Apr; 27(4):777-84. PubMed ID: 18383257 [TBL] [Abstract][Full Text] [Related]
8. Biological magnetic resonance imaging using laser-polarized 129Xe. Albert MS; Cates GD; Driehuys B; Happer W; Saam B; Springer CS; Wishnia A Nature; 1994 Jul; 370(6486):199-201. PubMed ID: 8028666 [TBL] [Abstract][Full Text] [Related]
9. An investigation of pipeline materials for continuous hyperpolarized 129Xe gas spectroscopy. Saito M; Hiraga T; Hattori M; Murakami S; Nakai T Magn Reson Imaging; 2005 May; 23(4):607-10. PubMed ID: 15919608 [TBL] [Abstract][Full Text] [Related]
10. Steady-state free precession with hyperpolarized 3He: experiments and theory. Wild JM; Teh K; Woodhouse N; Paley MN; Fichele S; de Zanche N; Kasuboski L J Magn Reson; 2006 Nov; 183(1):13-24. PubMed ID: 16890464 [TBL] [Abstract][Full Text] [Related]
11. Evaluation of emphysema severity and progression in a rabbit model: comparison of hyperpolarized 3He and 129Xe diffusion MRI with lung morphometry. Mata JF; Altes TA; Cai J; Ruppert K; Mitzner W; Hagspiel KD; Patel B; Salerno M; Brookeman JR; de Lange EE; Tobias WA; Wang HT; Cates GD; Mugler JP J Appl Physiol (1985); 2007 Mar; 102(3):1273-80. PubMed ID: 17110518 [TBL] [Abstract][Full Text] [Related]
12. Functional MR imaging of pulmonary ventilation using hyperpolarized noble gases. Guenther D; Hanisch G; Kauczor HU Acta Radiol; 2000 Nov; 41(6):519-28. PubMed ID: 11092469 [TBL] [Abstract][Full Text] [Related]
13. Magnetic resonance imaging of dissolved hyperpolarized 129Xe using a membrane-based continuous flow system. Amor N; Zänker PP; Blümler P; Meise FM; Schreiber LM; Scholz A; Schmiedeskamp J; Spiess HW; Münnemann K J Magn Reson; 2009 Nov; 201(1):93-9. PubMed ID: 19729327 [TBL] [Abstract][Full Text] [Related]
14. Measurements of regional alveolar oxygen pressure using hyperpolarized 3He MRI. Fischer MC; Kadlecek S; Yu J; Ishii M; Emami K; Vahdat V; Lipson DA; Rizi RR Acad Radiol; 2005 Nov; 12(11):1430-9. PubMed ID: 16253855 [TBL] [Abstract][Full Text] [Related]
15. Theoretical prediction and experimental measurement of the field dependence of the apparent transverse relaxation of hyperpolarized noble gases in lungs. Parra-Robles J; Dominguez Viqueira W; Xu X; Ouriadov A; Santyr GE J Magn Reson; 2008 May; 192(1):85-91. PubMed ID: 18358755 [TBL] [Abstract][Full Text] [Related]
16. Feasibility of functional magnetic resonance lung imaging in Australia with long distance transport of hyperpolarized helium from Germany. Thien F; Friese M; Cowin G; Maillet D; Wang D; Galloway G; Brereton I; Robinson PJ; Heil W; Thompson B Respirology; 2008 Jun; 13(4):599-602. PubMed ID: 18494950 [TBL] [Abstract][Full Text] [Related]
17. MOXE: a model of gas exchange for hyperpolarized 129Xe magnetic resonance of the lung. Chang YV Magn Reson Med; 2013 Mar; 69(3):884-90. PubMed ID: 22565296 [TBL] [Abstract][Full Text] [Related]
18. Controlling diffusion of 3He by buffer gases: a structural contrast agent in lung MRI. Acosta RH; Blümler P; Agulles-Pedrós L; Morbach AE; Schmiedeskamp J; Herweling A; Wolf U; Scholz A; Schreiber WG; Heil W; Thelen M; Spiess HW J Magn Reson Imaging; 2006 Dec; 24(6):1291-7. PubMed ID: 17078046 [TBL] [Abstract][Full Text] [Related]
19. Hyperpolarized 83Kr and 129Xe NMR relaxation measurements of hydrated surfaces: implications for materials science and pulmonary diagnostics. Cleveland ZI; Stupic KF; Pavlovskaya GE; Repine JE; Wooten JB; Meersmann T J Am Chem Soc; 2007 Feb; 129(6):1784-92. PubMed ID: 17243679 [TBL] [Abstract][Full Text] [Related]
20. Distal airways in humans: dynamic hyperpolarized 3He MR imaging--feasibility. Tooker AC; Hong KS; McKinstry EL; Costello P; Jolesz FA; Albert MS Radiology; 2003 May; 227(2):575-9. PubMed ID: 12663822 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]