BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

241 related articles for article (PubMed ID: 15528069)

  • 1. A Monte Carlo brachytherapy study for dose distribution prediction in an inhomogeneous medium.
    Slate LJ; Elson HR; Lamba MA; Kassing WM; Soldano M; Barrett WL
    Med Dosim; 2004; 29(4):271-8. PubMed ID: 15528069
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Polymer gel dosimetry for the TG-43 dosimetric characterization of a new 125I interstitial brachytherapy seed.
    Papagiannis P; Pantelis E; Georgiou E; Karaiskos P; Angelopoulos A; Sakelliou L; Stiliaris S; Baltas D; Seimenis I
    Phys Med Biol; 2006 Apr; 51(8):2101-11. PubMed ID: 16585848
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Study of the IsoAid ADVANTAGE (125)I brachytherapy source dosimetric parameters using Monte Carlo simulation.
    Sadeghi M; Hamed Hosseini S
    Appl Radiat Isot; 2010 Jan; 68(1):211-3. PubMed ID: 19762248
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Experimental measurements and Monte Carlo calculations of dosimetric parameters of the IRA1-103Pd brachytherapy source.
    Sadeghi M; Hosseini SH; Raisali G
    Appl Radiat Isot; 2008 Oct; 66(10):1431-7. PubMed ID: 18387806
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Anisotropy functions for 103Pd, 125I, and 192Ir interstitial brachytherapy sources.
    Nath R; Meigooni AS; Muench P; Melillo A
    Med Phys; 1993; 20(5):1465-73. PubMed ID: 8289730
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dosimetric parameters estimation using PENELOPE Monte-Carlo simulation code: Model 6711 a 125I brachytherapy seed.
    Rodríguez EA; Alcón EP; Rodriguez ML; Gutt F; de Almeida CE
    Appl Radiat Isot; 2005 Jul; 63(1):41-8. PubMed ID: 15866446
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Monte carlo investigation of the dosimetric properties of the new 103Pd BrachySeedPd-103 Model Pd-1 source.
    Chan GH; Prestwich WV
    Med Phys; 2002 Sep; 29(9):1984-90. PubMed ID: 12349919
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of dosimetric parameters for various 192Ir brachytherapy sources under unbounded phantom geometry by Monte Carlo simulation.
    Devan K; Aruna P; Manigandan D; Bharanidharan G; Subbaiah KV; Sunny CS; Ganesan S
    Med Dosim; 2007; 32(4):305-15. PubMed ID: 17980833
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Approaches to calculating AAPM TG-43 brachytherapy dosimetry parameters for 137Cs, 125I, 192Ir, 103Pd, and 169Yb sources.
    Melhus CS; Rivard MJ
    Med Phys; 2006 Jun; 33(6):1729-37. PubMed ID: 16872080
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy assessment of the superposition principle for evaluating dose distributions of elongated and curved 103Pd and 192Ir brachytherapy sources.
    Bannon EA; Yang Y; Rivard MJ
    Med Phys; 2011 Jun; 38(6):2957-63. PubMed ID: 21815369
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Polymer gel dosimetry close to an 125I interstitial brachytherapy seed.
    Pantelis E; Lymperopoulou G; Papagiannis P; Sakelliou L; Stiliaris E; Sandilos P; Seimenis I; Kozicki M; Rosiak JM
    Phys Med Biol; 2005 Sep; 50(18):4371-84. PubMed ID: 16148399
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Monte Carlo and experimental characterization of the first AMIRS 103Pd brachytherapy source.
    Raisali G; Ghonchehnazi MG; Shokrani P; Sadeghi M
    Appl Radiat Isot; 2008 Dec; 66(12):1856-60. PubMed ID: 18657981
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A quantitative three-dimensional dose attenuation analysis around Fletcher-Suit-Delclos due to stainless steel tube for high-dose-rate brachytherapy by Monte Carlo calculations.
    Parsai EI; Zhang Z; Feldmeier JJ
    Brachytherapy; 2009; 8(3):318-23. PubMed ID: 19217355
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Radial dose functions for 103Pd, 125I, 169Yb and 192Ir brachytherapy sources: an EGS4 Monte Carlo study.
    Mainegra E; Capote R; López E
    Phys Med Biol; 2000 Mar; 45(3):703-17. PubMed ID: 10730965
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A Monte Carlo evaluation of the dosimetric characteristics of the EchoSeed Model 6733 (125)I brachytherapy source.
    Sowards KT; Meigooni AS
    Brachytherapy; 2002; 1(4):227-32. PubMed ID: 15062171
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dosimetric characteristic of a new 125I brachytherapy source.
    Sadeghi M; Khanmohammadi Z
    Radiat Prot Dosimetry; 2011 Nov; 147(3):451-6. PubMed ID: 21233096
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dosimetric parameters for three low-energy brachytherapy sources using the Monte Carlo N-particle code.
    DeMarco JJ; Hugo G; Solberg TD
    Med Phys; 2002 May; 29(5):662-8. PubMed ID: 12033560
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Monte Carlo and thermoluminescence dosimetry of the new IsoSeed model I25.S17 125I interstitial brachytherapy seed.
    Lymperopoulou G; Papagiannis P; Sakelliou L; Karaiskos P; Sandilos P; Przykutta A; Baltas D
    Med Phys; 2005 Nov; 32(11):3313-7. PubMed ID: 16370418
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A modern Monte Carlo investigation of the TG-43 dosimetry parameters for an 125I seed already having AAPM consensus data.
    Aryal P; Molloy JA; Rivard MJ
    Med Phys; 2014 Feb; 41(2):021702. PubMed ID: 24506593
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Thermoluminescent and Monte Carlo dosimetry of IR06-103Pd brachytherapy source.
    Saidi P; Sadeghi M; Hosseini SH; Tenreiro C
    J Appl Clin Med Phys; 2011 Nov; 12(4):3581. PubMed ID: 22089014
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.