These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

206 related articles for article (PubMed ID: 15532860)

  • 1. Child dies when ventilator alarms fail to warn of an occluded tracheostomy tube.
    Health Devices; 2004 Sep; 33(9):335-6. PubMed ID: 15532860
    [No Abstract]   [Full Text] [Related]  

  • 2. Confusing restart procedure on the Puritan-Bennett Achieva ventilator could delay ventilation.
    Health Devices; 2004 Sep; 33(9):337. PubMed ID: 15532861
    [No Abstract]   [Full Text] [Related]  

  • 3. Home ventilator low-pressure alarms fail to detect accidental decannulation with pediatric tracheostomy tubes.
    Kun SS; Nakamura CT; Ripka JF; Davidson Ward SL; Keens TG
    Chest; 2001 Feb; 119(2):562-4. PubMed ID: 11171738
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Portable volume ventilators.
    Health Devices; 1992 Aug; 21(8):255-89. PubMed ID: 1644577
    [No Abstract]   [Full Text] [Related]  

  • 5. Ventilator-disconnect and death: a case study and a safety device.
    Lowery WS
    Respir Care; 2010 Jun; 55(6):774-6. PubMed ID: 20507663
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Safety in using metal tracheostomy tubes].
    Kock KF; Thomsen JL
    Ugeskr Laeger; 1994 Mar; 156(13):1960-2. PubMed ID: 8009689
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Safe reliable atraumatic replacement of misplaced paediatric tracheostomy tubes.
    Lyons MJ; Cooke J; Cochrane LA; Albert DM
    Int J Pediatr Otorhinolaryngol; 2007 Nov; 71(11):1743-6. PubMed ID: 17850888
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A technique of positive-pressure single-lung ventilation via a silicone T-Y stent.
    Quigley RL; Bannister KH; Chisdak MW; Reitknecht FL
    Ann Thorac Surg; 1996 Aug; 62(2):570-1. PubMed ID: 8694627
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Converting from an endotracheal tube to tracheostomy: description of a proposed alternative approach.
    Pickard KB
    AANA J; 2006 Feb; 74(1):35-8. PubMed ID: 16483066
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Barotrauma from CPAP systems lacking pressure relief.
    Health Devices; 1996 Sep; 25(9):343-5. PubMed ID: 8878727
    [No Abstract]   [Full Text] [Related]  

  • 11. [Airway obstruction after tracheostomy in a neurologically impaired child].
    Kawase M; Arakura K; Kawase S; Shiozawa R; Inoue Y
    Masui; 2008 Mar; 57(3):352-4. PubMed ID: 18341003
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Non-invasive ventilation in children with upper airway obstruction.
    Wormald R; Naude A; Rowley H
    Int J Pediatr Otorhinolaryngol; 2009 Apr; 73(4):551-4. PubMed ID: 19144413
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Hazard report. Unfamiliarity with differences in the way ventilators set pressure-control values may lead to lung injuries.
    Health Devices; 2010 Jun; 39(6):206-7. PubMed ID: 21309286
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [The Dräger Universal-Ventilator 1--a clinical and functional analysis of its potential applications].
    Kilian J; Lotz P; Spilker D
    Klin Anasthesiol Intensivther; 1979; 20():296-315. PubMed ID: 395364
    [No Abstract]   [Full Text] [Related]  

  • 15. Modified PEEP equipment for the Emerson 3-PV ventilator.
    Perry DW
    Respir Care; 1976 Dec; 21(12):1250. PubMed ID: 10314784
    [No Abstract]   [Full Text] [Related]  

  • 16. An alarm for monitoring CPAP.
    Carter B; Clare D; Hochmann M; Osborne A; Fraser T
    Anaesth Intensive Care; 1993 Apr; 21(2):208-10. PubMed ID: 8517514
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Field 5. Safety practices procedures for mechanical ventilation. French-speaking Society of Intensive Care. French Society of Anesthesia and Resuscitation].
    Girault C; Auriant I; Jaber S
    Ann Fr Anesth Reanim; 2008 Oct; 27(10):e77-89. PubMed ID: 18951756
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Clarification of performance characteristics of the Vortran Automatic Resuscitator.
    Piper SD
    Respir Care; 2008 Aug; 53(8):1089-90; author reply 1090-1. PubMed ID: 18655747
    [No Abstract]   [Full Text] [Related]  

  • 19. Breathing easy through the Y2K transition. Validating ventilator and CPAP unit contingency plans.
    Health Devices; 1999 Dec; 28(12):502-6. PubMed ID: 10604090
    [No Abstract]   [Full Text] [Related]  

  • 20. Failure of Penlon IDP ventilator alarm.
    Anaesthesia; 1983 Jul; 38(7):703-4. PubMed ID: 6346935
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 11.