These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

166 related articles for article (PubMed ID: 15532994)

  • 21. Effect of bearing geometry and structure support on transient elastohydrodynamic lubrication of metal-on-metal hip implants.
    Liu F; Jin Z; Roberts P; Grigoris P
    J Biomech; 2007; 40(6):1340-9. PubMed ID: 16824529
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Wear and deformation of ceramic-on-polyethylene total hip replacements with joint laxity and swing phase microseparation.
    Williams S; Butterfield M; Stewart T; Ingham E; Stone M; Fisher J
    Proc Inst Mech Eng H; 2003; 217(2):147-53. PubMed ID: 12666782
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Contact mechanics analysis of metal-on-metal hip resurfacing prostheses.
    Udofia IJ; Yew A; Jin ZM
    Proc Inst Mech Eng H; 2004; 218(5):293-305. PubMed ID: 15532995
    [TBL] [Abstract][Full Text] [Related]  

  • 24. 3-D model of a total hip replacement in vivo providing hydrodynamic pressure and film thickness for walking and bicycling.
    Meyer DM; Tichy JA
    J Biomech Eng; 2003 Dec; 125(6):777-84. PubMed ID: 14986401
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Contact mechanics and elastohydrodynamic lubrication in a novel metal-on-metal hip implant with an aspherical bearing surface.
    Meng Q; Gao L; Liu F; Yang P; Fisher J; Jin Z
    J Biomech; 2010 Mar; 43(5):849-57. PubMed ID: 20003978
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus.
    Jin ZM; Dowson D; Fisher J
    Proc Inst Mech Eng H; 1997; 211(3):247-56. PubMed ID: 9256001
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Normalization of load and clearance effects in ball-in-socket-like replacements.
    Ciavarella M; Strozzi A; Baldini A; Giacopini M
    Proc Inst Mech Eng H; 2007 Aug; 221(6):601-11. PubMed ID: 17937199
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Determination of lubricating film thickness for permeable hydrogel and non-permeable polyurethane layers bonded to a rigid substrate with particular reference to cushion form hip joint replacements.
    McClure G; Jin ZM; Fisher J; Tighe BJ
    Proc Inst Mech Eng H; 1996; 210(2):89-93. PubMed ID: 8688121
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Design considerations for cushion form bearings in artificial hip joints.
    Dowson D; Fisher J; Jin ZM; Auger DD; Jobbins B
    Proc Inst Mech Eng H; 1991; 205(2):59-68. PubMed ID: 1840721
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Stress analysis of cushion form bearings for total hip replacements.
    Jin ZM; Dowson D; Fisher J
    Proc Inst Mech Eng H; 1991; 205(4):219-26. PubMed ID: 1670079
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Friction of composite cushion bearings for total knee joint replacements under adverse lubrication conditions.
    Stewart T; Jin ZM; Fisher J
    Proc Inst Mech Eng H; 1997; 211(6):451-65. PubMed ID: 9509883
    [TBL] [Abstract][Full Text] [Related]  

  • 32. An axisymmetric contact model of ultra high molecular weight polyethylene cups against metallic femoral heads for artificial hip joint replacements.
    Jin ZM; Heng SM; Ng HW; Auger DD
    Proc Inst Mech Eng H; 1999; 213(4):317-27. PubMed ID: 10466363
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Time-dependent elastohydrodynamic lubrication analysis of total knee replacement under walking conditions.
    Su Y; Yang P; Fu Z; Jin Z; Wang C
    Comput Methods Biomech Biomed Engin; 2011 Jun; 14(6):539-48. PubMed ID: 21390940
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Effect of gap outside contact area on lubrication of metal-on-Metal total hip replacement.
    Al-Saffar AA; Evans SL
    Comput Methods Biomech Biomed Engin; 2020 Aug; 23(11):675-689. PubMed ID: 32396392
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [FE-analysis of surface stresses for the tribological system in total hip prostheses].
    Behrens BA; Helms G; Pösse O; Nolte I; Meyer-Lindenberg A; Rittmann P; Windhagen H; Pressel T
    Biomed Tech (Berl); 2006 Dec; 51(5-6):367-70. PubMed ID: 17155874
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A general axisymmetric contact mechanics model for layered surfaces, with particular reference to artificial hip joint replacements.
    Jin ZM
    Proc Inst Mech Eng H; 2000; 214(5):425-35. PubMed ID: 11109850
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Metal-on-metal hip joint tribology.
    Dowson D; Jin ZM
    Proc Inst Mech Eng H; 2006 Feb; 220(2):107-18. PubMed ID: 16669380
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A full numerical solution to the problem of microelastohydrodynamic lubrication of a stationary compliant wavy layered surface firmly bonded to a rigid substrate with particular reference to human synovial joints.
    Dowson D; Jin ZM
    Proc Inst Mech Eng H; 1992; 206(4):185-93. PubMed ID: 1300110
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Prediction of transient lubricating film thickness in knee prostheses with compliant layers.
    Jin ZM; Dowson D; Fisher J; Ohtsuki N; Murakami T; Higaki H; Moriyama S
    Proc Inst Mech Eng H; 1998; 212(3):157-64. PubMed ID: 9695634
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Effect of simplifications of bone and components inclination on the elastohydrodynamic lubrication modeling of metal-on-metal hip resurfacing prosthesis.
    Meng Q; Liu F; Fisher J; Jin Z
    Proc Inst Mech Eng H; 2013 May; 227(5):523-34. PubMed ID: 23637262
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.