These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

166 related articles for article (PubMed ID: 15532994)

  • 41. Transient elastohydrodynamic lubrication analysis of a novel metal-on-metal hip prosthesis with a non-spherical femoral bearing surface.
    Meng QE; Liu F; Fisher J; Jin ZM
    Proc Inst Mech Eng H; 2011 Jan; 225(1):25-37. PubMed ID: 21381485
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Calculation of theoretical lubrication regimes in two-piece first metatarsophalangeal prostheses.
    Joyce TJ
    Biomed Mater Eng; 2008; 18(1):45-51. PubMed ID: 18198406
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Contact mechanics of metal-on-metal hip implants employing a metallic cup with a UHMWPE backing.
    Liu F; Jin ZM; Grigoris P; Hirt F; Rieker C
    Proc Inst Mech Eng H; 2003; 217(3):207-13. PubMed ID: 12807161
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Analysis of contact mechanics in McKee-farrar metal-on-metal hip implants.
    Yew A; Jagatia M; Ensaff H; Jin ZM
    Proc Inst Mech Eng H; 2003; 217(5):333-40. PubMed ID: 14558645
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Coupling of dynamics and contact mechanics of artificial hip joints in a pendulum model.
    Liu H; Ellison PJ; Xu H; Jin Z
    Proc Inst Mech Eng H; 2010; 224(8):989-1003. PubMed ID: 20923116
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Lubrication and friction prediction in metal-on-metal hip implants.
    Wang FC; Brockett C; Williams S; Udofia I; Fisher J; Jin ZM
    Phys Med Biol; 2008 Mar; 53(5):1277-93. PubMed ID: 18296762
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Determination of contact area in 'cushion form' bearings for artificial hip joints.
    O'Carroll S; Jin ZM; Dowson D; Fisher J; Jobbins B
    Proc Inst Mech Eng H; 1990; 204(4):217-23. PubMed ID: 2090124
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Geometric element analysis of fretting in a model of a modular femoral component of a hip implant.
    Lewis G
    Biomed Mater Eng; 2004; 14(1):43-51. PubMed ID: 14757952
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Changes in the contact area during the bedding-in wear of different sizes of metal on metal hip prostheses.
    Hu XQ; Isaac GH; Fisher J
    Biomed Mater Eng; 2004; 14(2):145-9. PubMed ID: 15156105
    [TBL] [Abstract][Full Text] [Related]  

  • 50. A finite element method comparison of wear in two metal-on-metal total hip prostheses.
    Cosmi F; Hoglievina M; Fancellu G; Martinelli B
    Proc Inst Mech Eng H; 2006 Nov; 220(8):871-9. PubMed ID: 17236520
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Temperature prediction in a finite element model for sliding contact analysis of total hip prosthesis.
    Suhendra N; Stachowiak GW
    Proc Inst Mech Eng H; 2004; 218(5):361-70. PubMed ID: 15533001
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Compliant-layer tibial bearing inserts: friction testing of different materials and designs for a new generation of prostheses that mimic the natural joint.
    Jones E; Scholes SC; Unsworth A; Burgess IC
    Proc Inst Mech Eng H; 2008 Nov; 222(8):1197-208. PubMed ID: 19143414
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Effect of head size on wear properties of metal-on-metal bearings of hip prostheses, and comparison with wear properties of metal-on-polyethylene bearings using hip simulator.
    Okazaki Y
    J Mech Behav Biomed Mater; 2014 Mar; 31():152-63. PubMed ID: 24290355
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Comments on "Tribology and total hip joint replacement: current concepts in mechanical simulation" [Med. Eng. Phys. 30 (2008) 1305-1317].
    Asseman F
    Med Eng Phys; 2009 Jul; 31(6):730; author reply 731. PubMed ID: 19342287
    [No Abstract]   [Full Text] [Related]  

  • 55. Third-body abrasive wear challenge of 32 mm conventional and 44 mm highly crosslinked polyethylene liners in a hip simulator model.
    Sorimachi T; Clarke IC; Williams PA; Gustafson A; Yamamoto K
    Proc Inst Mech Eng H; 2009 Jul; 223(5):607-23. PubMed ID: 19623913
    [TBL] [Abstract][Full Text] [Related]  

  • 56. The influence of clearance on friction, lubrication and squeaking in large diameter metal-on-metal hip replacements.
    Brockett CL; Harper P; Williams S; Isaac GH; Dwyer-Joyce RS; Jin Z; Fisher J
    J Mater Sci Mater Med; 2008 Apr; 19(4):1575-9. PubMed ID: 17990078
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Effect of contact stress on friction and wear of ultra-high molecular weight polyethylene in total hip replacement.
    Wang A; Essner A; Klein R
    Proc Inst Mech Eng H; 2001; 215(2):133-9. PubMed ID: 11382072
    [TBL] [Abstract][Full Text] [Related]  

  • 58. A novel method to assess primary stability of press-fit acetabular cups.
    Crosnier EA; Keogh PS; Miles AW
    Proc Inst Mech Eng H; 2014 Nov; 228(11):1126-34. PubMed ID: 25384445
    [TBL] [Abstract][Full Text] [Related]  

  • 59. The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements.
    Smith SL; Dowson D; Goldsmith AA
    Proc Inst Mech Eng H; 2001; 215(2):161-70. PubMed ID: 11382075
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Cushion form bearings for total knee joint replacement. Part 1: Design,friction and lubrication.
    Auger DD; Dowson D; Fisher J
    Proc Inst Mech Eng H; 1995; 209(2):73-81. PubMed ID: 7495429
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.