These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

231 related articles for article (PubMed ID: 15539376)

  • 21. Is it acceptable to use coagulation plasma samples stored at room temperature and 4°C for 24 hours for additional prothrombin time, activated partial thromboplastin time, fibrinogen, antithrombin, and D-dimer testing?
    Rimac V; Coen Herak D
    Int J Lab Hematol; 2017 Oct; 39(5):475-481. PubMed ID: 28488785
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Hemostasis test compatibility with capped and uncapped tubes.
    Finnegan K; Cutsforth G
    Clin Lab Sci; 2011; 24(4):215-20. PubMed ID: 22288219
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Influence of blood collection in plastic vs. glass evacuated serum-separator tubes on hormone and tumour marker levels.
    Smets EM; Dijkstra-Lagemaat JE; Blankenstein MA
    Clin Chem Lab Med; 2004 Apr; 42(4):435-9. PubMed ID: 15147155
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Is the use of plastic capillary tubes justified for blood gases analysis?].
    Daurès MF; Bozonnat MC; Cristol JP
    Ann Biol Clin (Paris); 2011; 69(1):126-30. PubMed ID: 21464003
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Inappropriate statistics in coagulation collection tube comparison study.
    Tetrault GA
    Am J Clin Pathol; 2005 Jul; 124(1):155; author reply 155-6. PubMed ID: 16086504
    [No Abstract]   [Full Text] [Related]  

  • 26. Comparative study of blood collection tubes and thromboplastin reagents for correction of INR discrepancies: a proposal for maximum allowable magnesium contamination in sodium citrate anticoagulant solutions.
    van den Besselaar AM; van Zanten AP; Brantjes HM; Elisen MG; van der Meer FJ; Poland DC; Sturk A; Leyte A; Castel A
    Am J Clin Pathol; 2012 Aug; 138(2):248-54. PubMed ID: 22904137
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Effects of EDTA on routine and specialized coagulation testing and an easy method to distinguish EDTA-treated from citrated plasma samples.
    Crist RA; Gibbs K; Rodgers GM; Smock KJ
    Lab Hematol; 2009; 15(4):45-8. PubMed ID: 19923105
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Loss of factor VIII and von Willebrand factor activities during cold storage of whole blood is reversed by rewarming.
    Refaai MA; Van Cott EM; Lukoszyk M; Hughes J; Eby CS
    Lab Hematol; 2006; 12(2):99-102. PubMed ID: 16751138
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Effects of vigorous mixing of blood vacuum tubes on laboratory test results.
    Lima-Oliveira G; Lippi G; Salvagno GL; Montagnana M; Gelati M; Volanski W; Boritiza KC; Picheth G; Guidi GC
    Clin Biochem; 2013 Feb; 46(3):250-4. PubMed ID: 23146916
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The effect of specimen hemolysis on coagulation test results.
    Laga AC; Cheves TA; Sweeney JD
    Am J Clin Pathol; 2006 Nov; 126(5):748-55. PubMed ID: 17050072
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Routine coagulation testing in Vacutainer® Citrate Plus tubes filled at minimum or optimal volume.
    Balboni F; Barbui S; Gallo M; Berardi M; Vezzosi M; Lippi G
    Diagnosis (Berl); 2020 Jan; 7(1):55-60. PubMed ID: 31421038
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Minimum specimen volume requirements for routine coagulation testing: dependence on citrate concentration.
    Adcock DM; Kressin DC; Marlar RA
    Am J Clin Pathol; 1998 May; 109(5):595-9. PubMed ID: 9576579
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Sodium citrate blood contamination by K2 -ethylenediaminetetraacetic acid (EDTA): impact on routine coagulation testing.
    Lima-Oliveira G; Salvagno GL; Danese E; Favaloro EJ; Guidi GC; Lippi G
    Int J Lab Hematol; 2015 Jun; 37(3):403-9. PubMed ID: 25308126
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Effect on routine and special coagulation testing values of citrate anticoagulant adjustment in patients with high hematocrit values.
    Marlar RA; Potts RM; Marlar AA
    Am J Clin Pathol; 2006 Sep; 126(3):400-5. PubMed ID: 16880137
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Influence of temperature and time before centrifugation of specimens for routine coagulation testing.
    Salvagno GL; Lippi G; Montagnana M; Franchini M; Poli G; Guidi GC
    Int J Lab Hematol; 2009 Aug; 31(4):462-7. PubMed ID: 18371059
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Unsuitability of evacuated tubes for monitoring heparin therapy by activated partial thromboplastin time.
    Heyns AD; van den Berg DJ; Kleynhans PH; du Toit PW
    J Clin Pathol; 1981 Jan; 34(1):63-8. PubMed ID: 7462439
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effect of telavancin (Vibativ) on routine coagulation test results.
    Gosselin R; Dager W; Roberts A; Freeman L; Gandy L; Gregg J; Dwyre D
    Am J Clin Pathol; 2011 Dec; 136(6):848-54. PubMed ID: 22095369
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparison of glass K3EDTA versus plastic K2EDTA blood-drawing tubes for complete blood counts, reticulocyte counts, and white blood cell differentials.
    Van Cott EM; Lewandrowski KB; Patel S; Grzybek DY; Patel HS; Fletcher SR; Kratz A
    Lab Hematol; 2003; 9(1):10-4. PubMed ID: 12661823
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A low volume specimen container suitable for monitoring the aPTT of heparinized patients.
    Ray MJ; Carroll PA; Just SJ; Hawson GA
    Blood Coagul Fibrinolysis; 1993 Oct; 4(5):805-7. PubMed ID: 8292732
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Effects of storage and thawing conditions on coagulation testing.
    Gosselin RC; Honeychurch K; Kang HJ; Dwyre DM
    Int J Lab Hematol; 2015 Aug; 37(4):551-9. PubMed ID: 25766006
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.