These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

298 related articles for article (PubMed ID: 15539726)

  • 1. Supplemental oxygen impairs detection of hypoventilation by pulse oximetry.
    Fu ES; Downs JB; Schweiger JW; Miguel RV; Smith RA
    Chest; 2004 Nov; 126(5):1552-8. PubMed ID: 15539726
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Microstream capnography improves patient monitoring during moderate sedation: a randomized, controlled trial.
    Lightdale JR; Goldmann DA; Feldman HA; Newburg AR; DiNardo JA; Fox VL
    Pediatrics; 2006 Jun; 117(6):e1170-8. PubMed ID: 16702250
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Respiratory depression detected by capnography among children in the postanesthesia care unit: a cross-sectional study.
    Langhan ML; Li FY; Lichtor JL
    Paediatr Anaesth; 2016 Oct; 26(10):1010-7. PubMed ID: 27396979
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Supplemental oxygen compromises the use of pulse oximetry for detection of apnea and hypoventilation during sedation in simulated pediatric patients.
    Keidan I; Gravenstein D; Berkenstadt H; Ziv A; Shavit I; Sidi A
    Pediatrics; 2008 Aug; 122(2):293-8. PubMed ID: 18676546
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Home-based overnight transcutaneous capnography/pulse oximetry for diagnosing nocturnal hypoventilation associated with neuromuscular disorders.
    Bauman KA; Kurili A; Schmidt SL; Rodriguez GM; Chiodo AE; Sitrin RG
    Arch Phys Med Rehabil; 2013 Jan; 94(1):46-52. PubMed ID: 22964272
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Characteristics of Desaturation and Respiratory Rate in Postoperative Patients Breathing Room Air Versus Supplemental Oxygen: Are They Different?
    Taenzer AH; Perreard IM; MacKenzie T; McGrath SP
    Anesth Analg; 2018 Mar; 126(3):826-832. PubMed ID: 29293179
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The impact of capnography monitoring among children and adolescents in the postanesthesia care unit: a randomized controlled trial.
    Langhan ML; Li FY; Lichtor JL
    Paediatr Anaesth; 2017 Apr; 27(4):385-393. PubMed ID: 28177565
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Detection of hypoventilation during thoracoscopy: combined cutaneous carbon dioxide tension and oximetry monitoring with a new digital sensor.
    Chhajed PN; Kaegi B; Rajasekaran R; Tamm M
    Chest; 2005 Feb; 127(2):585-8. PubMed ID: 15706000
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A comparative evaluation of capnometry versus pulse oximetry during procedural sedation and analgesia on room air.
    Sivilotti ML; Messenger DW; van Vlymen J; Dungey PE; Murray HE
    CJEM; 2010 Sep; 12(5):397-404. PubMed ID: 20880431
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Capnography is superior to pulse oximetry for the detection of respiratory depression during colonoscopy.
    Cacho G; Pérez-Calle JL; Barbado A; Lledó JL; Ojea R; Fernández-Rodríguez CM
    Rev Esp Enferm Dig; 2010 Feb; 102(2):86-9. PubMed ID: 20361844
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A randomized, controlled trial of transcutaneous carbon dioxide monitoring during ERCP.
    Nelson DB; Freeman ML; Silvis SE; Cass OW; Yakshe PN; Vennes J; Stahnke LL; Herman M; Hodges J
    Gastrointest Endosc; 2000 Mar; 51(3):288-95. PubMed ID: 10699773
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of transport time and FiO2 on SpO2 during transport from the OR to the PACU.
    Hoffman C; Nakamoto D; Okal R; Clochesy JM
    Nurse Anesth; 1991 Sep; 2(3):119-25. PubMed ID: 1888786
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Hypoxemia after general anesthesia].
    Aust H; Eberhart LH; Kranke P; Arndt C; Bleimüller C; Zoremba M; Rüsch D
    Anaesthesist; 2012 Apr; 61(4):299-309. PubMed ID: 22526741
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Does pulse oximetry accurately monitor a patient's ventilation during sedated endoscopy under oxygen supplementation?
    Arakawa H; Kaise M; Sumiyama K; Saito S; Suzuki T; Tajiri H
    Singapore Med J; 2013 Apr; 54(4):212-5. PubMed ID: 23624448
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The utility of the pretracheal stethoscope in detecting ventilatory abnormalities during propofol sedation in children.
    Boriosi JP; Zhao Q; Preston A; Hollman GA
    Paediatr Anaesth; 2019 Jun; 29(6):604-610. PubMed ID: 30801831
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of pulse oximetry and capnography in healthy and compromised horses during spontaneous and controlled ventilation.
    Koenig J; McDonell W; Valverde A
    Can J Vet Res; 2003 Jul; 67(3):169-74. PubMed ID: 12889721
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ambulatory surgery: room air versus nasal cannula oxygen during transport after general anesthesia.
    Mathes DD; Conaway MR; Ross WT
    Anesth Analg; 2001 Oct; 93(4):917-21. PubMed ID: 11574357
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Pulse oximetry reduces the unnecessary administration of oxygen in the postanesthesia recovery period].
    Hernández-Palazón J; Moya Solera J; Tortosa Serrano JA; Ros Sempere M; Burguillos López S; Doménech Asensi P
    Rev Esp Anestesiol Reanim; 2002; 49(7):346-9. PubMed ID: 12455113
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Integrated pulmonary index can predict respiratory compromise in high-risk patients in the post-anesthesia care unit: a prospective, observational study.
    Kuroe Y; Mihara Y; Okahara S; Ishii K; Kanazawa T; Morimatsu H
    BMC Anesthesiol; 2021 Apr; 21(1):123. PubMed ID: 33882856
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pulse oximetry monitoring can change routine oxygen supplementation practices in the postanesthesia care unit.
    DiBenedetto RJ; Graves SA; Gravenstein N; Konicek C
    Anesth Analg; 1994 Feb; 78(2):365-8. PubMed ID: 8311292
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.