These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 1554645)

  • 1. The PAR Technology Corneal Topography System.
    Belin MW; Litoff D; Strods SJ; Winn SS; Smith RS
    Refract Corneal Surg; 1992; 8(1):88-96. PubMed ID: 1554645
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Intraoperative raster photogrammetry--the PAR Corneal Topography System.
    Belin MW
    J Cataract Refract Surg; 1993; 19 Suppl():188-92. PubMed ID: 8450443
    [TBL] [Abstract][Full Text] [Related]  

  • 3. PAR Corneal Topography System (PAR CTS): the clinical application of close-range photogrammetry.
    Belin MW; Cambier JL; Nabors JR; Ratliff CD
    Optom Vis Sci; 1995 Nov; 72(11):828-37. PubMed ID: 8587772
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accuracy of the PAR corneal topography system with spatial misalignment.
    Belin MW; Zloty P
    CLAO J; 1993 Jan; 19(1):64-8. PubMed ID: 8453756
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Computer-assisted corneal topography: accuracy and reproducibility of the topographic modeling system.
    Legeais JM; Ren Q; Simon G; Parel JM
    Refract Corneal Surg; 1993; 9(5):347-57. PubMed ID: 8241039
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Corneal topography using rasterstereography.
    Arffa RC; Warnicki JW; Rehkopf PG
    Refract Corneal Surg; 1989; 5(6):414-7. PubMed ID: 2488840
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Intraobserver repeatability and interobserver reproducibility of corneal measurements in normal eyes using an optical coherence tomography-Placido disk device.
    Shah JM; Han D; Htoon HM; Mehta JS
    J Cataract Refract Surg; 2015 Feb; 41(2):372-81. PubMed ID: 25661131
    [TBL] [Abstract][Full Text] [Related]  

  • 8. How accurately can videokeratographic systems measure surface elevation?
    Applegate RA; Nuñez R; Buettner J; Howland HC
    Optom Vis Sci; 1995 Nov; 72(11):785-92. PubMed ID: 8587766
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Preliminary results of a wide-angle corneal topography system for Placido-based videokeratographers].
    Carvalho LA
    Arq Bras Oftalmol; 2008; 71(2):197-206. PubMed ID: 18516419
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of the accuracy and reproducibility of the keratometer and the EyeSys Corneal Analysis System Model I.
    Koch DD; Wakil JS; Samuelson SW; Haft EA
    J Cataract Refract Surg; 1992 Jul; 18(4):342-7. PubMed ID: 1501084
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Spatial and frequency domain techniques for segmentation of Placido images and accuracy implications for videokeratography.
    de Carvalho LA; Bruno OM
    Comput Methods Programs Biomed; 2005 Aug; 79(2):111-9. PubMed ID: 16006006
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Videokeratography.
    Binder PS
    CLAO J; 1995 Apr; 21(2):133-44. PubMed ID: 7796524
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Characterization of the inherent error in a spherically-biased corneal topography system in mapping a radially aspheric surface.
    Roberts C
    J Refract Corneal Surg; 1994; 10(2):103-11; discussion 112-6. PubMed ID: 7517283
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Corneal thickness, curvature, and elevation readings in normal corneas: combined Placido-Scheimpflug system versus combined Placido-scanning-slit system.
    Guilbert E; Saad A; Grise-Dulac A; Gatinel D
    J Cataract Refract Surg; 2012 Jul; 38(7):1198-206. PubMed ID: 22727289
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Analysis of the effects of astigmatism and misalignment on corneal surface reconstruction from photokeratoscopic data.
    Wang JY; Rice DA; Klyce SD
    Refract Corneal Surg; 1991; 7(2):129-40. PubMed ID: 2043558
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of three computerized videokeratoscopy systems with keratometry.
    Moura RC; Bowyer BL; Stevens SX; Rowsey JJ
    Cornea; 1998 Sep; 17(5):522-8. PubMed ID: 9756447
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Estimating variability in placido-based topographic systems.
    Kounis GA; Tsilimbaris MK; Kymionis GD; Ginis HS; Pallikaris IG
    Optom Vis Sci; 2007 Oct; 84(10):962-8. PubMed ID: 18049359
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Enhancing the standard operating range of a Placido disk videokeratoscope for corneal surface estimation.
    Alkhaldi W; Iskander DR; Zoubir AM; Collins MJ
    IEEE Trans Biomed Eng; 2009 Mar; 56(3):800-9. PubMed ID: 19389686
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The accuracy of 'power' maps to display curvature data in corneal topography systems.
    Roberts C
    Invest Ophthalmol Vis Sci; 1994 Aug; 35(9):3525-32. PubMed ID: 8056528
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Principles of operation, accuracy and precision of an Eye Surface Profiler.
    Iskander DR; Wachel P; Simpson PN; Consejo A; Jesus DA
    Ophthalmic Physiol Opt; 2016 May; 36(3):266-78. PubMed ID: 27112224
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.