3. PAR Corneal Topography System (PAR CTS): the clinical application of close-range photogrammetry. Belin MW; Cambier JL; Nabors JR; Ratliff CD Optom Vis Sci; 1995 Nov; 72(11):828-37. PubMed ID: 8587772 [TBL] [Abstract][Full Text] [Related]
4. Accuracy of the PAR corneal topography system with spatial misalignment. Belin MW; Zloty P CLAO J; 1993 Jan; 19(1):64-8. PubMed ID: 8453756 [TBL] [Abstract][Full Text] [Related]
5. Computer-assisted corneal topography: accuracy and reproducibility of the topographic modeling system. Legeais JM; Ren Q; Simon G; Parel JM Refract Corneal Surg; 1993; 9(5):347-57. PubMed ID: 8241039 [TBL] [Abstract][Full Text] [Related]
7. Intraobserver repeatability and interobserver reproducibility of corneal measurements in normal eyes using an optical coherence tomography-Placido disk device. Shah JM; Han D; Htoon HM; Mehta JS J Cataract Refract Surg; 2015 Feb; 41(2):372-81. PubMed ID: 25661131 [TBL] [Abstract][Full Text] [Related]
8. How accurately can videokeratographic systems measure surface elevation? Applegate RA; Nuñez R; Buettner J; Howland HC Optom Vis Sci; 1995 Nov; 72(11):785-92. PubMed ID: 8587766 [TBL] [Abstract][Full Text] [Related]
9. [Preliminary results of a wide-angle corneal topography system for Placido-based videokeratographers]. Carvalho LA Arq Bras Oftalmol; 2008; 71(2):197-206. PubMed ID: 18516419 [TBL] [Abstract][Full Text] [Related]
10. Comparison of the accuracy and reproducibility of the keratometer and the EyeSys Corneal Analysis System Model I. Koch DD; Wakil JS; Samuelson SW; Haft EA J Cataract Refract Surg; 1992 Jul; 18(4):342-7. PubMed ID: 1501084 [TBL] [Abstract][Full Text] [Related]
11. Spatial and frequency domain techniques for segmentation of Placido images and accuracy implications for videokeratography. de Carvalho LA; Bruno OM Comput Methods Programs Biomed; 2005 Aug; 79(2):111-9. PubMed ID: 16006006 [TBL] [Abstract][Full Text] [Related]
13. Characterization of the inherent error in a spherically-biased corneal topography system in mapping a radially aspheric surface. Roberts C J Refract Corneal Surg; 1994; 10(2):103-11; discussion 112-6. PubMed ID: 7517283 [TBL] [Abstract][Full Text] [Related]
14. Corneal thickness, curvature, and elevation readings in normal corneas: combined Placido-Scheimpflug system versus combined Placido-scanning-slit system. Guilbert E; Saad A; Grise-Dulac A; Gatinel D J Cataract Refract Surg; 2012 Jul; 38(7):1198-206. PubMed ID: 22727289 [TBL] [Abstract][Full Text] [Related]
15. Analysis of the effects of astigmatism and misalignment on corneal surface reconstruction from photokeratoscopic data. Wang JY; Rice DA; Klyce SD Refract Corneal Surg; 1991; 7(2):129-40. PubMed ID: 2043558 [TBL] [Abstract][Full Text] [Related]
16. Comparison of three computerized videokeratoscopy systems with keratometry. Moura RC; Bowyer BL; Stevens SX; Rowsey JJ Cornea; 1998 Sep; 17(5):522-8. PubMed ID: 9756447 [TBL] [Abstract][Full Text] [Related]
18. Enhancing the standard operating range of a Placido disk videokeratoscope for corneal surface estimation. Alkhaldi W; Iskander DR; Zoubir AM; Collins MJ IEEE Trans Biomed Eng; 2009 Mar; 56(3):800-9. PubMed ID: 19389686 [TBL] [Abstract][Full Text] [Related]
19. The accuracy of 'power' maps to display curvature data in corneal topography systems. Roberts C Invest Ophthalmol Vis Sci; 1994 Aug; 35(9):3525-32. PubMed ID: 8056528 [TBL] [Abstract][Full Text] [Related]
20. Principles of operation, accuracy and precision of an Eye Surface Profiler. Iskander DR; Wachel P; Simpson PN; Consejo A; Jesus DA Ophthalmic Physiol Opt; 2016 May; 36(3):266-78. PubMed ID: 27112224 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]