BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

258 related articles for article (PubMed ID: 15546820)

  • 1. Effect on oximetry of dyes used for sentinel lymph node biopsy.
    Piñero A; Illana J; García-Palenciano C; Cañizarese F; Canteras M; Cañadillas V; Durán E; Parilla P
    Arch Surg; 2004 Nov; 139(11):1204-7. PubMed ID: 15546820
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pulse oximeter changes with sentinel lymph node biopsy in breast cancer.
    El-Tamer M; Komenaka IK; Curry S; Troxel AB; Ditkoff BA; Schnabel FR
    Arch Surg; 2003 Nov; 138(11):1257-60. PubMed ID: 14609878
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Factitious oxygen desaturation after isosulfan blue injection.
    Heinle E; Burdumy T; Recabaren J
    Am Surg; 2003 Oct; 69(10):899-901. PubMed ID: 14570371
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Sentinel lymph node mapping of breast cancer: a case-control study of methylene blue tracer compared to isosulfan blue.
    Eldrageely K; Vargas MP; Khalkhali I; Venegas R; Burla M; Gonzalez KD; Vargas HI
    Am Surg; 2004 Oct; 70(10):872-5. PubMed ID: 15529840
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intraoperative decrease in pulse oximeter readings following injection of isosulfan blue.
    Hoskin RW; Granger R
    Can J Anaesth; 2001 Jan; 48(1):38-40. PubMed ID: 11212047
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A comparison of the adverse reactions associated with isosulfan blue versus methylene blue dye in sentinel lymph node biopsy for breast cancer.
    Thevarajah S; Huston TL; Simmons RM
    Am J Surg; 2005 Feb; 189(2):236-9. PubMed ID: 15720998
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Efficacy of methylene blue dye in localization of sentinel lymph node in breast cancer patients.
    Nour A
    Breast J; 2004; 10(5):388-91. PubMed ID: 15327490
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A comparison of the adverse reactions associated with isosulfan blue versus methylene blue dye in sentinel lymph node biopsy for breast cancer.
    Aydogan F; Celik V; Uras C; Salihoglu Z; Topuz U
    Am J Surg; 2008 Feb; 195(2):277-8. PubMed ID: 18194680
    [No Abstract]   [Full Text] [Related]  

  • 9. Pulse oximetry declines due to intradermal isosulfan blue dye: a controlled prospective study.
    Momeni R; Ariyan S
    Ann Surg Oncol; 2004 Apr; 11(4):434-7. PubMed ID: 15070605
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Is blue dye indicated for sentinel lymph node biopsy in breast cancer patients with a positive lymphoscintigram?
    Degnim AC; Oh K; Cimmino VM; Diehl KM; Chang AE; Newman LA; Sabel MS
    Ann Surg Oncol; 2005 Sep; 12(9):712-7. PubMed ID: 16079955
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Anaphylaxis to isosulfan blue dye during sentinel lymph node biopsy.
    Sandhu S; Farag E; Argalious M
    J Clin Anesth; 2005 Dec; 17(8):633-5. PubMed ID: 16427538
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Occurrence of prolonged injection site mass with methylene blue but not isosulfan blue after the sentinel node procedure.
    Shirah GR; Bouton ME; Komenaka IK
    Arch Surg; 2011 Feb; 146(2):137-41. PubMed ID: 21339422
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Methylene blue dye--a safe and effective alternative for sentinel lymph node localization.
    Varghese P; Abdel-Rahman AT; Akberali S; Mostafa A; Gattuso JM; Carpenter R
    Breast J; 2008; 14(1):61-7. PubMed ID: 18186867
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Concordance of peritumoral technetium 99m colloid and subareolar blue dye injection in breast cancer sentinel lymph node biopsy.
    Kargozaran H; Shah M; Li Y; Beckett L; Gandour-Edwards R; Schneider PD; Khatri VP
    J Surg Res; 2007 Nov; 143(1):126-9. PubMed ID: 17950081
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A prospective analysis of the effect of blue-dye volume on sentinel lymph node mapping success and incidence of allergic reaction in patients with breast cancer.
    King TA; Fey JV; Van Zee KJ; Heerdt AS; Gemignani ML; Port ER; Sclafani L; Sacchini V; Petrek JA; Cody HS; Borgen PI; Montgomery LL
    Ann Surg Oncol; 2004 May; 11(5):535-41. PubMed ID: 15123464
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The use of radioisotope combined with isosulfan Blue dye is not superior to radioisotope alone for the identification of sentinel lymph nodes in patients with breast cancer.
    Bines S; Kopkash K; Ali A; Fogg L; Wool N
    Surgery; 2008 Oct; 144(4):606-9; discussion 609-10. PubMed ID: 18847645
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A prospective trial comparing 1% lymphazurin vs 1% methylene blue in sentinel lymph node mapping of gastrointestinal tumors.
    Soni M; Saha S; Korant A; Fritz P; Chakravarty B; Sirop S; Gayar A; Iddings D; Wiese D
    Ann Surg Oncol; 2009 Aug; 16(8):2224-30. PubMed ID: 19484313
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Experimental study of sentinel lymph node biopsy in thyroid by using three kinds of vital dyes at different concentration and dose].
    Li X; Wang J; Zhou Z
    Lin Chuang Er Bi Yan Hou Tou Jing Wai Ke Za Zhi; 2007 Nov; 21(21):988-90. PubMed ID: 18309656
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Can methylene blue only be used in sentinel lymph node biopsy for breast cancer?
    Golshan M; Nakhlis F
    Breast J; 2006; 12(5):428-30. PubMed ID: 16958960
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Validation of sentinel node in breast cancer].
    Vergara-Fernández O; Cortés-González R; Medina-Franco H
    Rev Invest Clin; 2004; 56(3):309-13. PubMed ID: 15612512
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.