258 related articles for article (PubMed ID: 15546820)
1. Effect on oximetry of dyes used for sentinel lymph node biopsy.
Piñero A; Illana J; García-Palenciano C; Cañizarese F; Canteras M; Cañadillas V; Durán E; Parilla P
Arch Surg; 2004 Nov; 139(11):1204-7. PubMed ID: 15546820
[TBL] [Abstract][Full Text] [Related]
2. Pulse oximeter changes with sentinel lymph node biopsy in breast cancer.
El-Tamer M; Komenaka IK; Curry S; Troxel AB; Ditkoff BA; Schnabel FR
Arch Surg; 2003 Nov; 138(11):1257-60. PubMed ID: 14609878
[TBL] [Abstract][Full Text] [Related]
3. Factitious oxygen desaturation after isosulfan blue injection.
Heinle E; Burdumy T; Recabaren J
Am Surg; 2003 Oct; 69(10):899-901. PubMed ID: 14570371
[TBL] [Abstract][Full Text] [Related]
4. Sentinel lymph node mapping of breast cancer: a case-control study of methylene blue tracer compared to isosulfan blue.
Eldrageely K; Vargas MP; Khalkhali I; Venegas R; Burla M; Gonzalez KD; Vargas HI
Am Surg; 2004 Oct; 70(10):872-5. PubMed ID: 15529840
[TBL] [Abstract][Full Text] [Related]
5. Intraoperative decrease in pulse oximeter readings following injection of isosulfan blue.
Hoskin RW; Granger R
Can J Anaesth; 2001 Jan; 48(1):38-40. PubMed ID: 11212047
[TBL] [Abstract][Full Text] [Related]
6. A comparison of the adverse reactions associated with isosulfan blue versus methylene blue dye in sentinel lymph node biopsy for breast cancer.
Thevarajah S; Huston TL; Simmons RM
Am J Surg; 2005 Feb; 189(2):236-9. PubMed ID: 15720998
[TBL] [Abstract][Full Text] [Related]
7. Efficacy of methylene blue dye in localization of sentinel lymph node in breast cancer patients.
Nour A
Breast J; 2004; 10(5):388-91. PubMed ID: 15327490
[TBL] [Abstract][Full Text] [Related]
8. A comparison of the adverse reactions associated with isosulfan blue versus methylene blue dye in sentinel lymph node biopsy for breast cancer.
Aydogan F; Celik V; Uras C; Salihoglu Z; Topuz U
Am J Surg; 2008 Feb; 195(2):277-8. PubMed ID: 18194680
[No Abstract] [Full Text] [Related]
9. Pulse oximetry declines due to intradermal isosulfan blue dye: a controlled prospective study.
Momeni R; Ariyan S
Ann Surg Oncol; 2004 Apr; 11(4):434-7. PubMed ID: 15070605
[TBL] [Abstract][Full Text] [Related]
10. Is blue dye indicated for sentinel lymph node biopsy in breast cancer patients with a positive lymphoscintigram?
Degnim AC; Oh K; Cimmino VM; Diehl KM; Chang AE; Newman LA; Sabel MS
Ann Surg Oncol; 2005 Sep; 12(9):712-7. PubMed ID: 16079955
[TBL] [Abstract][Full Text] [Related]
11. Anaphylaxis to isosulfan blue dye during sentinel lymph node biopsy.
Sandhu S; Farag E; Argalious M
J Clin Anesth; 2005 Dec; 17(8):633-5. PubMed ID: 16427538
[TBL] [Abstract][Full Text] [Related]
12. Occurrence of prolonged injection site mass with methylene blue but not isosulfan blue after the sentinel node procedure.
Shirah GR; Bouton ME; Komenaka IK
Arch Surg; 2011 Feb; 146(2):137-41. PubMed ID: 21339422
[TBL] [Abstract][Full Text] [Related]
13. Methylene blue dye--a safe and effective alternative for sentinel lymph node localization.
Varghese P; Abdel-Rahman AT; Akberali S; Mostafa A; Gattuso JM; Carpenter R
Breast J; 2008; 14(1):61-7. PubMed ID: 18186867
[TBL] [Abstract][Full Text] [Related]
14. Concordance of peritumoral technetium 99m colloid and subareolar blue dye injection in breast cancer sentinel lymph node biopsy.
Kargozaran H; Shah M; Li Y; Beckett L; Gandour-Edwards R; Schneider PD; Khatri VP
J Surg Res; 2007 Nov; 143(1):126-9. PubMed ID: 17950081
[TBL] [Abstract][Full Text] [Related]
15. A prospective analysis of the effect of blue-dye volume on sentinel lymph node mapping success and incidence of allergic reaction in patients with breast cancer.
King TA; Fey JV; Van Zee KJ; Heerdt AS; Gemignani ML; Port ER; Sclafani L; Sacchini V; Petrek JA; Cody HS; Borgen PI; Montgomery LL
Ann Surg Oncol; 2004 May; 11(5):535-41. PubMed ID: 15123464
[TBL] [Abstract][Full Text] [Related]
16. The use of radioisotope combined with isosulfan Blue dye is not superior to radioisotope alone for the identification of sentinel lymph nodes in patients with breast cancer.
Bines S; Kopkash K; Ali A; Fogg L; Wool N
Surgery; 2008 Oct; 144(4):606-9; discussion 609-10. PubMed ID: 18847645
[TBL] [Abstract][Full Text] [Related]
17. A prospective trial comparing 1% lymphazurin vs 1% methylene blue in sentinel lymph node mapping of gastrointestinal tumors.
Soni M; Saha S; Korant A; Fritz P; Chakravarty B; Sirop S; Gayar A; Iddings D; Wiese D
Ann Surg Oncol; 2009 Aug; 16(8):2224-30. PubMed ID: 19484313
[TBL] [Abstract][Full Text] [Related]
18. [Experimental study of sentinel lymph node biopsy in thyroid by using three kinds of vital dyes at different concentration and dose].
Li X; Wang J; Zhou Z
Lin Chuang Er Bi Yan Hou Tou Jing Wai Ke Za Zhi; 2007 Nov; 21(21):988-90. PubMed ID: 18309656
[TBL] [Abstract][Full Text] [Related]
19. Can methylene blue only be used in sentinel lymph node biopsy for breast cancer?
Golshan M; Nakhlis F
Breast J; 2006; 12(5):428-30. PubMed ID: 16958960
[TBL] [Abstract][Full Text] [Related]
20. [Validation of sentinel node in breast cancer].
Vergara-Fernández O; Cortés-González R; Medina-Franco H
Rev Invest Clin; 2004; 56(3):309-13. PubMed ID: 15612512
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]