These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
142 related articles for article (PubMed ID: 15548801)
1. Impact factors on intraocular pressure measurements in healthy subjects. Theelen T; Meulendijks CF; Geurts DE; van Leeuwen A; Voet NB; Deutman AF Br J Ophthalmol; 2004 Dec; 88(12):1510-1. PubMed ID: 15548801 [TBL] [Abstract][Full Text] [Related]
2. Effect of a tight necktie on intraocular pressure. Teng C; Gurses-Ozden R; Liebmann JM; Tello C; Ritch R Br J Ophthalmol; 2003 Aug; 87(8):946-8. PubMed ID: 12881330 [TBL] [Abstract][Full Text] [Related]
3. [Comparison of precision of the TonoPenXL with the Goldmann and Draeger applanation tonometer in a sitting and recumbent position of the patients -- a clinical study on 251 eyes]. Viestenz A; Lausen B; Jünemann AM; Mardin CY Klin Monbl Augenheilkd; 2002 Nov; 219(11):785-90. PubMed ID: 12494368 [TBL] [Abstract][Full Text] [Related]
4. Effect of head position on intraocular pressure in horses. Komáromy AM; Garg CD; Ying GS; Liu C Am J Vet Res; 2006 Jul; 67(7):1232-5. PubMed ID: 16817748 [TBL] [Abstract][Full Text] [Related]
5. Clinical comparison of pascal dynamic contour tonometry and goldmann applanation tonometry in asymmetric open-angle glaucoma. Sullivan-Mee M; Halverson KD; Qualls C J Glaucoma; 2007 Dec; 16(8):694-9. PubMed ID: 18091457 [TBL] [Abstract][Full Text] [Related]
6. Comparison of Goldmann applanation and applanation resonance tonometry in a biomicroscope-based in vitro porcine eye model. Hallberg P; Santala K; Lindén C; Lindahl OA; Eklund A J Med Eng Technol; 2006; 30(6):345-52. PubMed ID: 17060162 [TBL] [Abstract][Full Text] [Related]
8. Relation between office intraocular pressure and 24-hour intraocular pressure in patients with primary open-angle glaucoma treated with a combination of topical antiglaucoma eye drops. Nakakura S; Nomura Y; Ataka S; Shiraki K J Glaucoma; 2007 Mar; 16(2):201-4. PubMed ID: 17473730 [TBL] [Abstract][Full Text] [Related]
9. Underestimate of tonometric readings after photorefractive keratectomy increases at higher intraocular pressure levels. Tamburrelli C; Giudiceandrea A; Vaiano AS; Caputo CG; Gullà F; Salgarello T Invest Ophthalmol Vis Sci; 2005 Sep; 46(9):3208-13. PubMed ID: 16123420 [TBL] [Abstract][Full Text] [Related]
10. Corneal parameters and difference between goldmann applanation tonometry and dynamic contour tonometry in normal eyes. Lanza M; Borrelli M; De Bernardo M; Filosa ML; Rosa N J Glaucoma; 2008 Sep; 17(6):460-4. PubMed ID: 18794680 [TBL] [Abstract][Full Text] [Related]
11. Clinical evaluation of applanation resonance tonometry: a comparison with Goldmann applanation tonometry. Hallberg P; Eklund A; Bäcklund T; Lindén C J Glaucoma; 2007 Jan; 16(1):88-93. PubMed ID: 17224756 [TBL] [Abstract][Full Text] [Related]
12. Nocturnal elevation of intraocular pressure in young adults. Liu JH; Kripke DF; Hoffman RE; Twa MD; Loving RT; Rex KM; Gupta N; Weinreb RN Invest Ophthalmol Vis Sci; 1998 Dec; 39(13):2707-12. PubMed ID: 9856781 [TBL] [Abstract][Full Text] [Related]
13. Measurements of intraocular pressure by Goldmann tonometry, Tonopen XL, and the transpalpebral tonometer, TGDc-01, after penetrating keratoplasty: a comparativye study. Shemesh G; Waisbourd M; Varssano D; Michaeli A; Lazar M; Kurtz S Cornea; 2009 Aug; 28(7):724-7. PubMed ID: 19574919 [TBL] [Abstract][Full Text] [Related]
14. The effect of contact lens induced corneal edema on Goldmann applanation tonometry measurements. Hamilton KE; Pye DC; Hali A; Lin C; Kam P; Ngyuen T J Glaucoma; 2007 Jan; 16(1):153-8. PubMed ID: 17224766 [TBL] [Abstract][Full Text] [Related]
15. Short-term effect of acupuncture on intraocular pressure in healthy subjects. Meira-Freitas D; Cariello AJ; Vita RC; Tabosa A; Melo LA Acupunct Med; 2010 Mar; 28(1):25-7. PubMed ID: 20351373 [TBL] [Abstract][Full Text] [Related]
16. Dynamic contour tonometry for intraocular pressure measurement. Kamppeter BA; Jonas JB Am J Ophthalmol; 2005 Aug; 140(2):318-20. PubMed ID: 16086958 [TBL] [Abstract][Full Text] [Related]
17. Assessment of the pascal dynamic contour tonometer in measuring intraocular pressure in keratoconic eyes. Papastergiou GI; Kozobolis V; Siganos DS J Glaucoma; 2008 Sep; 17(6):484-8. PubMed ID: 18794685 [TBL] [Abstract][Full Text] [Related]
18. [Intraocular pressure measurements with the Proview self-tonometer in comparison of Goldmann applanation tonometry in healthy and glaucomatous eyes]. Meyer MW; Yevelenko V; Hoy L; Meyer A; Erb C Klin Monbl Augenheilkd; 2006 Nov; 223(11):899-903. PubMed ID: 17131250 [TBL] [Abstract][Full Text] [Related]
19. Comparison of the rebound tonometer (ICare) to the applanation tonometer (Tonopen XL) in normotensive dogs. Leiva M; Naranjo C; Peña MT Vet Ophthalmol; 2006; 9(1):17-21. PubMed ID: 16409240 [TBL] [Abstract][Full Text] [Related]
20. [Validity and reproducibility of sensor contact lens profiles in comparison to applanation tonometry in healthy eyes]. Faschinger C; Mossböck G; Krainz S Klin Monbl Augenheilkd; 2012 Dec; 229(12):1209-14. PubMed ID: 23172649 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]