156 related articles for article (PubMed ID: 15549478)
1. Expiratory tidal volume displayed on Bird 8400 STi can exceed the preset tidal volume due to cardiogenic oscillation: a lung model study.
Imanaka H; Takeuchi M; Tachibana K; Nishimura M
J Anesth; 2004; 18(4):313-5. PubMed ID: 15549478
[TBL] [Abstract][Full Text] [Related]
2. [Exhaled tidal volume is overestimated due to cardiogenic oscillation: effects of ventilator and mode].
Imanaka H; Takeuchi M; Tachibana K; Takauchi Y; Inamori N; Nishimura M
Masui; 2005 Mar; 54(3):254-9. PubMed ID: 15794101
[TBL] [Abstract][Full Text] [Related]
3. Exhaled tidal volume overestimation in mechanically ventilated patients with large cardiogenic oscillation.
Imanaka H; Takeuchi M; Tachibana K; Nishimura M
Crit Care Med; 2004 Jul; 32(7):1546-9. PubMed ID: 15241100
[TBL] [Abstract][Full Text] [Related]
4. [A study of the parameters of the delivered tidal volume. Ventilation on a lung model using the CICERO anesthetic ventilator].
Schirmer U; Villwock J; Fösel T; Schreiber M; Goertz A; Georgieff M
Anaesthesist; 1992 Dec; 41(12):785-9. PubMed ID: 1489078
[TBL] [Abstract][Full Text] [Related]
5. [Mechanical ventilation in an anesthetic circle system using the lowest tidal volume--studies of 3 anesthesia ventilators in a lung model and an animal experiment].
Fösel T; Schirmer U; Wick C; Pfenninger E; Siegler W; Altemeyer KH
Anaesthesist; 1991 Nov; 40(11):624-8. PubMed ID: 1755533
[TBL] [Abstract][Full Text] [Related]
6. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation?
Bachiller PR; McDonough JM; Feldman JM
Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850
[TBL] [Abstract][Full Text] [Related]
7. Effect of inspiratory time on tidal volume delivery in anesthesia and intensive care unit ventilators operating in pressure control mode.
Tung A; Drum ML; Morgan S
J Clin Anesth; 2005 Feb; 17(1):8-15. PubMed ID: 15721723
[TBL] [Abstract][Full Text] [Related]
8. Are tidal volume measurements in neonatal pressure-controlled ventilation accurate?
Chow LC; Vanderhal A; Raber J; Sola A
Pediatr Pulmonol; 2002 Sep; 34(3):196-202. PubMed ID: 12203848
[TBL] [Abstract][Full Text] [Related]
9. Excessive tidal volume from breath stacking during lung-protective ventilation for acute lung injury.
Pohlman MC; McCallister KE; Schweickert WD; Pohlman AS; Nigos CP; Krishnan JA; Charbeneau JT; Gehlbach BK; Kress JP; Hall JB
Crit Care Med; 2008 Nov; 36(11):3019-23. PubMed ID: 18824913
[TBL] [Abstract][Full Text] [Related]
10. The impact of closed endotracheal suctioning systems on mechanical ventilator performance.
El Masry A; Williams PF; Chipman DW; Kratohvil JP; Kacmarek RM
Respir Care; 2005 Mar; 50(3):345-53. PubMed ID: 15737244
[TBL] [Abstract][Full Text] [Related]
11. Autotriggering caused by cardiogenic oscillation during flow-triggered mechanical ventilation.
Imanaka H; Nishimura M; Takeuchi M; Kimball WR; Yahagi N; Kumon K
Crit Care Med; 2000 Feb; 28(2):402-7. PubMed ID: 10708174
[TBL] [Abstract][Full Text] [Related]
12. Patient-ventilator synchrony during pressure-targeted versus flow-targeted small tidal volume assisted ventilation.
Yang LY; Huang YC; Macintyre NR
J Crit Care; 2007 Sep; 22(3):252-7. PubMed ID: 17869978
[TBL] [Abstract][Full Text] [Related]
13. Relationship between endotracheal tube leakage and under-reading of tidal volume in neonatal ventilators.
Mahmoud RA; Fischer HS; Proquitté H; Shalaby HM; Schmalisch G
Acta Paediatr; 2009 Jul; 98(7):1116-22. PubMed ID: 19432838
[TBL] [Abstract][Full Text] [Related]
14. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation.
DiBlasi RM; Salyer JW; Zignego JC; Redding GJ; Richardson CP
Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147
[TBL] [Abstract][Full Text] [Related]
15. Tidal volume delivery during high-frequency oscillatory ventilation in adults with acute respiratory distress syndrome.
Hager DN; Fessler HE; Kaczka DW; Shanholtz CB; Fuld MK; Simon BA; Brower RG
Crit Care Med; 2007 Jun; 35(6):1522-9. PubMed ID: 17440422
[TBL] [Abstract][Full Text] [Related]
16. Volume guarantee ventilation, interrupted expiration, and expiratory braking.
McCallion N; Lau R; Dargaville PA; Morley CJ
Arch Dis Child; 2005 Aug; 90(8):865-70. PubMed ID: 15886260
[TBL] [Abstract][Full Text] [Related]
17. Changes in delivered tidal volume with the addition of carbon dioxide to mechanical ventilation.
Tobias JD; Miltenberg L
Paediatr Anaesth; 2009 Mar; 19(3):240-3. PubMed ID: 19143961
[TBL] [Abstract][Full Text] [Related]
18. Variations in tidal volume with portable transport ventilators.
McGough EK; Banner MJ; Melker RJ
Respir Care; 1992 Mar; 37(3):233-9. PubMed ID: 10145629
[TBL] [Abstract][Full Text] [Related]
19. Patient-ventilator interaction: a general model for nonpassive mechanical ventilation.
Crooke PS; Head JD; Marini JJ; Hotchkiss JR
IMA J Math Appl Med Biol; 1998 Dec; 15(4):321-37. PubMed ID: 9951713
[TBL] [Abstract][Full Text] [Related]
20. Effect of Cardiogenic Oscillations on Trigger Delay During Pressure Support Ventilation.
Plens GM; Morais CC; Nakamura MA; Souza PN; Amato MB; Tucci MR; Costa EL
Respir Care; 2018 Jul; 63(7):865-872. PubMed ID: 29895701
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]