These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

160 related articles for article (PubMed ID: 15552118)

  • 1. Effects of slow flow on slice profile and NMR signal in fast imaging sequences.
    Gao JH; Gore JC
    Phys Med Biol; 1994 Sep; 39(9):1489-500. PubMed ID: 15552118
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Rapid inner-volume imaging in the steady-state with 3D selective excitation and small-tip fast recovery imaging.
    Sun H; Fessler JA; Noll DC; Nielsen JF
    Magn Reson Med; 2016 Oct; 76(4):1217-23. PubMed ID: 26507586
    [TBL] [Abstract][Full Text] [Related]  

  • 3. New insights into the mechanisms of signal formation in RF-spoiled gradient echo sequences.
    Denolin V; Azizieh C; Metens T
    Magn Reson Med; 2005 Oct; 54(4):937-54. PubMed ID: 16155898
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Simultaneous multislice imaging with slice-multiplexed RF pulses.
    Lee KJ; Wild JM; Griffiths PD; Paley MN
    Magn Reson Med; 2005 Oct; 54(4):755-60. PubMed ID: 16155891
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Rapid and robust variable flip angle T
    Heule R; Bieri O
    Magn Reson Med; 2017 Apr; 77(4):1606-1611. PubMed ID: 27098885
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Small tip angle three-dimensional tailored radiofrequency slab-select pulse for reduced B1 inhomogeneity at 3 T.
    Saekho S; Boada FE; Noll DC; Stenger VA
    Magn Reson Med; 2005 Feb; 53(2):479-84. PubMed ID: 15678525
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Advanced three-dimensional tailored RF pulse for signal recovery in T2*-weighted functional magnetic resonance imaging.
    Yip CY; Fessler JA; Noll DC
    Magn Reson Med; 2006 Nov; 56(5):1050-9. PubMed ID: 17041911
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Three-dimensional magnetization-prepared imaging using a concentric cylinders trajectory.
    Kwon KT; Wu HH; Shin T; Cukur T; Lustig M; Nishimura DG
    Magn Reson Med; 2014 May; 71(5):1700-10. PubMed ID: 23818212
    [TBL] [Abstract][Full Text] [Related]  

  • 9. T2-selective magnetization preparation pulses.
    Vidarsson L; Cunningham C; Gold GE; Pauly JM
    IEEE Trans Med Imaging; 2007 Jul; 26(7):981-9. PubMed ID: 17649911
    [TBL] [Abstract][Full Text] [Related]  

  • 10. On the use of steady-state signal equations for 2D TrueFISP imaging.
    Coolen BF; Heijman E; Nicolay K; Strijkers GJ
    Magn Reson Imaging; 2009 Jul; 27(6):815-22. PubMed ID: 19249169
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A multislice gradient echo pulse sequence for CEST imaging.
    Dixon WT; Hancu I; Ratnakar SJ; Sherry AD; Lenkinski RE; Alsop DC
    Magn Reson Med; 2010 Jan; 63(1):253-6. PubMed ID: 19918889
    [TBL] [Abstract][Full Text] [Related]  

  • 12. 2D-RF-pulse-encoded curved-slice imaging.
    Börnert P
    MAGMA; 2003 Jul; 16(2):86-92. PubMed ID: 12851831
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Accuracy of equilibrium magnetization mapping in sliced two-dimensional spoiled gradient-recalled echo pulse sequence with variable flip angle.
    Kuribayashi H; Sekino M; Minowa T; Maitani Y; Ohsaki H; Tsushima S; Hirai S; Ueda M; Katayama Y
    J Magn Reson Imaging; 2013 Nov; 38(5):1245-50. PubMed ID: 23390025
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fast three-dimensional inner volume excitations using parallel transmission and optimized k-space trajectories.
    Davids M; Schad LR; Wald LL; Guérin B
    Magn Reson Med; 2016 Oct; 76(4):1170-82. PubMed ID: 26527590
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Strategies for improved 3D small-tip fast recovery imaging.
    Sun H; Fessler JA; Noll DC; Nielsen JF
    Magn Reson Med; 2014 Aug; 72(2):389-98. PubMed ID: 24127132
    [TBL] [Abstract][Full Text] [Related]  

  • 16. SSFP and GRE phase contrast imaging using a three-echo readout.
    Nielsen JF; Nayak KS
    Magn Reson Med; 2007 Dec; 58(6):1288-93. PubMed ID: 17969073
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of the optimal imaging parameters of the RODEO pulse sequence by computer simulation.
    Miller I; Gao JH; Fox PT
    J Magn Reson Imaging; 1996; 6(4):684-9. PubMed ID: 8835963
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Numerical study of a macroscopic finite pulse model of the diffusion MRI signal.
    Li JR; Nguyen HT; Nguyen DV; Haddar H; Coatléven J; Le Bihan D
    J Magn Reson; 2014 Nov; 248():54-65. PubMed ID: 25314082
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Strategies for inner volume 3D fast spin echo magnetic resonance imaging using nonselective refocusing radio frequency pulses.
    Mitsouras D; Mulkern RV; Rybicki FJ
    Med Phys; 2006 Jan; 33(1):173-86. PubMed ID: 16485424
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Generalized encoding through the use of selective excitation in accelerated parallel MRI.
    Kyriakos WE; Hoge WS; Mitsouras D
    NMR Biomed; 2006 May; 19(3):379-92. PubMed ID: 16705639
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.