509 related articles for article (PubMed ID: 15552413)
1. Measurements of output factors with different detector types and Monte Carlo calculations of stopping-power ratios for degraded electron beams.
Björk P; Knöös T; Nilsson P
Phys Med Biol; 2004 Oct; 49(19):4493-506. PubMed ID: 15552413
[TBL] [Abstract][Full Text] [Related]
2. Determination of the KQclinfclin,Qmsr fmsr correction factors for detectors used with an 800 MU/min CyberKnife(®) system equipped with fixed collimators and a study of detector response to small photon beams using a Monte Carlo method.
Moignier C; Huet C; Makovicka L
Med Phys; 2014 Jul; 41(7):071702. PubMed ID: 24989371
[TBL] [Abstract][Full Text] [Related]
3. Output correction factors for nine small field detectors in 6 MV radiation therapy photon beams: a PENELOPE Monte Carlo study.
Benmakhlouf H; Sempau J; Andreo P
Med Phys; 2014 Apr; 41(4):041711. PubMed ID: 24694131
[TBL] [Abstract][Full Text] [Related]
4. Comparative dosimetry of diode and diamond detectors in electron beams for intraoperative radiation therapy.
Björk P; Knöös T; Nilsson P
Med Phys; 2000 Nov; 27(11):2580-8. PubMed ID: 11128310
[TBL] [Abstract][Full Text] [Related]
5. Ionization chamber dosimetry of small photon fields: a Monte Carlo study on stopping-power ratios for radiosurgery and IMRT beams.
Sánchez-Doblado F; Andreo P; Capote R; Leal A; Perucha M; Arráns R; Núñez L; Mainegra E; Lagares JI; Carrasco E
Phys Med Biol; 2003 Jul; 48(14):2081-99. PubMed ID: 12894972
[TBL] [Abstract][Full Text] [Related]
6. Diamond detector versus silicon diode and ion chamber in photon beams of different energy and field size.
Bucciolini M; Buonamici FB; Mazzocchi S; De Angelis C; Onori S; Cirrone GA
Med Phys; 2003 Aug; 30(8):2149-54. PubMed ID: 12945980
[TBL] [Abstract][Full Text] [Related]
7. Dosimetry characteristics of degraded electron beams investigated by Monte Carlo calculations in a setup for intraoperative radiation therapy.
Björk P; Nilsson P; Knöös T
Phys Med Biol; 2002 Jan; 47(2):239-56. PubMed ID: 11837615
[TBL] [Abstract][Full Text] [Related]
8. Properties of a commercial PTW-60019 synthetic diamond detector for the dosimetry of small radiotherapy beams.
Lárraga-Gutiérrez JM; Ballesteros-Zebadúa P; Rodríguez-Ponce M; García-Garduño OA; de la Cruz OO
Phys Med Biol; 2015 Jan; 60(2):905-24. PubMed ID: 25564826
[TBL] [Abstract][Full Text] [Related]
9. A Monte Carlo study on the PTW 60019 microDiamond detector.
Hartmann GH; Zink K
Med Phys; 2019 Nov; 46(11):5159-5172. PubMed ID: 31314919
[TBL] [Abstract][Full Text] [Related]
10. Spectral distribution of particle fluence in small field detectors and its implication on small field dosimetry.
Benmakhlouf H; Andreo P
Med Phys; 2017 Feb; 44(2):713-724. PubMed ID: 28032369
[TBL] [Abstract][Full Text] [Related]
11. Comparative dosimetry in narrow high-energy photon beams.
Westermark M; Arndt J; Nilsson B; Brahme A
Phys Med Biol; 2000 Mar; 45(3):685-702. PubMed ID: 10730964
[TBL] [Abstract][Full Text] [Related]
12. Calculation of stopping-power ratios using realistic clinical electron beams.
Ding GX; Rogers DW; Mackie TR
Med Phys; 1995 May; 22(5):489-501. PubMed ID: 7643785
[TBL] [Abstract][Full Text] [Related]
13. Monte Carlo calculated correction factors for diodes and ion chambers in small photon fields.
Czarnecki D; Zink K
Phys Med Biol; 2013 Apr; 58(8):2431-44. PubMed ID: 23514734
[TBL] [Abstract][Full Text] [Related]
14. Monte Carlo-based investigations on the impact of removing the flattening filter on beam quality specifiers for photon beam dosimetry.
Czarnecki D; Poppe B; Zink K
Med Phys; 2017 Jun; 44(6):2569-2580. PubMed ID: 28369978
[TBL] [Abstract][Full Text] [Related]
15. Detector to detector corrections: a comprehensive experimental study of detector specific correction factors for beam output measurements for small radiotherapy beams.
Azangwe G; Grochowska P; Georg D; Izewska J; Hopfgartner J; Lechner W; Andersen CE; Beierholm AR; Helt-Hansen J; Mizuno H; Fukumura A; Yajima K; Gouldstone C; Sharpe P; Meghzifene A; Palmans H
Med Phys; 2014 Jul; 41(7):072103. PubMed ID: 24989398
[TBL] [Abstract][Full Text] [Related]
16. A Monte Carlo simulation framework for electron beam dose calculations using Varian phase space files for TrueBeam Linacs.
Rodrigues A; Sawkey D; Yin FF; Wu Q
Med Phys; 2015 May; 42(5):2389-403. PubMed ID: 25979034
[TBL] [Abstract][Full Text] [Related]
17. Interface perturbation effects in high-energy electron beams.
Verhaegen F
Phys Med Biol; 2003 Mar; 48(6):687-705. PubMed ID: 12699189
[TBL] [Abstract][Full Text] [Related]
18. Experimental determination of the lateral dose response functions of detectors to be applied in the measurement of narrow photon-beam dose profiles.
Poppinga D; Meyners J; Delfs B; Muru A; Harder D; Poppe B; Looe HK
Phys Med Biol; 2015 Dec; 60(24):9421-36. PubMed ID: 26583596
[TBL] [Abstract][Full Text] [Related]
19. Effects of changes in stopping-power ratios with field size on electron beam relative output factors.
Zhang GG; Rogers DW; Cygler JE; Mackie TR
Med Phys; 1998 Sep; 25(9):1711-6. PubMed ID: 9775377
[TBL] [Abstract][Full Text] [Related]
20. Monte Carlo calculations for reference dosimetry of electron beams with the PTW Roos and NE2571 ion chambers.
Muir BR; Rogers DW
Med Phys; 2013 Dec; 40(12):121722. PubMed ID: 24320508
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]