89 related articles for article (PubMed ID: 1555551)
1. Gas leakage in eight anaesthesia circle systems.
Leuenberger M; Feigenwinter P; Zbinden AM
Eur J Anaesthesiol; 1992 Mar; 9(2):121-7. PubMed ID: 1555551
[TBL] [Abstract][Full Text] [Related]
2. [Inspiratory and expiratory resistance of 8 semi-closed circle systems].
Feigenwinter P; Zbinden AM
Anaesthesist; 1991 Aug; 40(8):441-5. PubMed ID: 1952036
[TBL] [Abstract][Full Text] [Related]
3. Fresh gas utilization of eight circle systems.
Zbinden AM; Feigenwinter P; Hutmacher M
Br J Anaesth; 1991 Oct; 67(4):492-9. PubMed ID: 1931411
[TBL] [Abstract][Full Text] [Related]
4. [Fresh gas flow and artificial respiration in anesthesia. Technical requirements for the adequate use of rebreathing systems].
Baum J; Sachs G
Anasth Intensivther Notfallmed; 1990 Feb; 25(1):72-8. PubMed ID: 2309993
[TBL] [Abstract][Full Text] [Related]
5. Time to a 90% change in gas concentration: a comparison of three semi-closed anesthesia breathing systems.
Dosch MP; Loeb RG; Brainerd TL; Stallwood JF; Lechner S
Anesth Analg; 2009 Apr; 108(4):1193-7. PubMed ID: 19299785
[TBL] [Abstract][Full Text] [Related]
6. [Anesthetic gas consumption and costs in a closed system with the PhysioFlex anesthesia equipment].
Biro P
Anaesthesist; 1993 Sep; 42(9):638-43. PubMed ID: 8214536
[TBL] [Abstract][Full Text] [Related]
7. [A study of 11 ventilators for anesthesia: laboratory testing].
Liu N; Beydon L; Bach B; Bonnet F; Clergue F; Fougere S; Louville Y; Nivoche Y
Ann Fr Anesth Reanim; 1992; 11(5):502-8. PubMed ID: 1476281
[TBL] [Abstract][Full Text] [Related]
8. Resistance, reverse flow and opening pressure of unidirectional valves.
Leibundgut D; Zbinden AM
Anaesthesia; 1995 Dec; 50(12):1065-9. PubMed ID: 8546289
[TBL] [Abstract][Full Text] [Related]
9. [Minimal flow anesthesia in newborn infants--advantages and risks].
Gebhardt R; Weiser UK
Anaesthesiol Reanim; 1999; 24(2):41-6. PubMed ID: 10372434
[TBL] [Abstract][Full Text] [Related]
10. [Mechanical ventilation in an anesthetic circle system using the lowest tidal volume--studies of 3 anesthesia ventilators in a lung model and an animal experiment].
Fösel T; Schirmer U; Wick C; Pfenninger E; Siegler W; Altemeyer KH
Anaesthesist; 1991 Nov; 40(11):624-8. PubMed ID: 1755533
[TBL] [Abstract][Full Text] [Related]
11. [Characteristics of the relative humidity and temperature in the inspiratory part of the Dräger circle system and their influence on the function of the ciliary epithelium].
Anger C; van Bömmel T; Phadana-anek S; Reich A; Büter J; Stahl H; Deitmer T
Anasth Intensivther Notfallmed; 1990 Feb; 25(1):107-11. PubMed ID: 2309990
[TBL] [Abstract][Full Text] [Related]
12. [An unusual cause of anesthetic ventilator malfunction].
Kawamata M; Mayumi T; Miyabe M; Namiki A
Masui; 1992 Dec; 41(12):1994-7. PubMed ID: 1479671
[TBL] [Abstract][Full Text] [Related]
13. [A computer-controlled closed circle system for ventilation during anesthesia and intensive care and its possibilities for patient monitoring].
Verkaaik AP; Rubreht J; van Dijk G; Westerkamp B; Erdmann W
Anaesthesiol Reanim; 1991; 16(3):208-19. PubMed ID: 1888427
[TBL] [Abstract][Full Text] [Related]
14. [Accessory anesthetic breathing systems: verification before use].
Otteni JC; Cazalaà JB; Beydon L; Bourgain JL; Dalens B; Feiss P; Nivoche Y; Servin F; Safran D
Ann Fr Anesth Reanim; 1999 Feb; 18(2):243-8. PubMed ID: 10207599
[TBL] [Abstract][Full Text] [Related]
15. Safety and efficacy of semi-closed circle ventilation in small infants.
Peters JW; Bezstarosti-van Eeden J; Erdmann W; Meursing AE
Paediatr Anaesth; 1998; 8(4):299-304. PubMed ID: 9672927
[TBL] [Abstract][Full Text] [Related]
16. A new ventilator converter with the Siemens Servo Ventilator--evaluation in a lung model.
Hesselvik JF; Bengtsson M; Johnson A
Acta Anaesthesiol Scand; 1992 Jan; 36(1):75-9. PubMed ID: 1539483
[TBL] [Abstract][Full Text] [Related]
17. [Evaluation of low flow closed anesthesia technique for oxygen, nitrous oxide and isoflurane using Engström Elsa Anesthesia System].
Nakae Y; Ichimiya T; Miyabe M; Igarashi M; Watanabe H; Namiki A
Masui; 1993 Apr; 42(4):579-84. PubMed ID: 8315800
[TBL] [Abstract][Full Text] [Related]
18. Detection of inner tube defects in co-axial circle and Bain breathing systems: a comparison of occlusion and Pethick tests.
Szypula KA; Ip JK; Bogod D; Yentis SM
Anaesthesia; 2008 Oct; 63(10):1092-5. PubMed ID: 18647290
[TBL] [Abstract][Full Text] [Related]
19. [Anesthesia equipment and respirators. Fundamentals].
Rathgeber J
Anaesthesist; 1993 Dec; 42(12):885-909. PubMed ID: 8304583
[TBL] [Abstract][Full Text] [Related]
20. [The effect of fresh gas flow on the minute volume of anesthesia ventilators with a gas reservoir].
Latorre F; Jantzen JP
Anaesthesist; 1990 Jul; 39(7):382-3. PubMed ID: 2386308
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]