These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

89 related articles for article (PubMed ID: 1555551)

  • 21. Flow resistance of coaxial breathing systems: investigation of a circuit disconnect.
    Sinclair A; van Bergen J
    Can J Anaesth; 1992 Jan; 39(1):90-4. PubMed ID: 1733540
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Preparation of the Dräger Fabius GS workstation for malignant hyperthermia-susceptible patients.
    Whitty RJ; Wong GK; Petroz GC; Pehora C; Crawford MW
    Can J Anaesth; 2009 Jul; 56(7):497-501. PubMed ID: 19399571
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Preparation of the Dräger Fabius anesthesia machine for the malignant-hyperthermia susceptible patient.
    Gunter JB; Ball J; Than-Win S
    Anesth Analg; 2008 Dec; 107(6):1936-45. PubMed ID: 19020141
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Clinical evaluation of Engström's electrically controlled ELSA for low flow closed circuit anesthesia].
    Igarashi M; Nakae Y; Ichimiya N; Watanabe H; Iwasaki H; Namiki A
    Masui; 1993 Feb; 42(2):249-54. PubMed ID: 8437358
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Comparative humidity measurements in semiclosed and semiopen systems with the additional use of artificial noses].
    Wick C; Altemeyer KH; Ahnefeld FW; Kilian J
    Anaesthesist; 1987 Apr; 36(4):172-6. PubMed ID: 3474907
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Anesthesia with the closed PhysioFlex system in comparison with conventional anesthesia procedures].
    Hargasser S; Breinbauer B; Kling M; Mielke L; Entholzner E; Malek A; Rust M; Hipp R
    Anaesthesiol Reanim; 1994; 19(6):149-54. PubMed ID: 7865063
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Efficiency of a mobile oxygen concentrator for mechanical ventilation in anesthesia. Studies with a metabolic lung model and early clinical results].
    Rathgeber J; Züchner K; Kietzmann D; Kraus E
    Anaesthesist; 1995 Sep; 44(9):643-50. PubMed ID: 7485926
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Quantitative comparison of ventilator-induced work during simulated CPAP in eight demand-flow valve ventilators].
    Nishimura M; Imanaka H; Taenaka N; Yoshiya I; Takezawa J
    Masui; 1989 Aug; 38(8):1017-29. PubMed ID: 2681861
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Temperature and humidity of the Dräger Cato anesthetic machine circuit.
    Wada H; Higuchi H; Arimura S
    J Anesth; 2003; 17(3):166-70. PubMed ID: 12911203
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Effects of carbon dioxide absorbent cooling and temperature gradient reduction on water condensation in the anaesthesia circuit.
    Hirabayashi G; Uchino H; Joko T; Kaneko H; Ishii N
    Br J Anaesth; 2008 Jan; 100(1):131-6. PubMed ID: 18029346
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A potential hazard involving the gas sampling line and the adjustable pressure limiting valve on the Drager Apollo Anesthesia Workstation.
    Robards C; Corda D
    Anesth Analg; 2010 Aug; 111(2):578-9; author reply 580. PubMed ID: 20664099
    [No Abstract]   [Full Text] [Related]  

  • 32. [Experienced anesthetists show better reaction to central gas supply dropout--an anesthesia simulator study].
    Lussi C; Grapengeter M; Schmitz B; Schüttler J
    Anasthesiol Intensivmed Notfallmed Schmerzther; 1998 Nov; 33(11):726-9. PubMed ID: 9861435
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Choice of respirators for anesthesia].
    Neidhardt A; Bachour K; Costes Y
    Agressologie; 1992; 33 Spec No 1():23-8. PubMed ID: 1306937
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Bacterial contamination and the effect of filters in anaesthetic circuits in a simulated patient model.
    Leijten DT; Rejger VS; Mouton RP
    J Hosp Infect; 1992 May; 21(1):51-60. PubMed ID: 1351496
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Anesthetic equipment: fresh gas delivery systems. II. Electronic systems].
    Otteni JC; Ancellin J; Cazalaà JB; Feiss P
    Ann Fr Anesth Reanim; 1999 Nov; 18(9):976-86. PubMed ID: 10615545
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Leakage of disposable breathing circuits.
    Wang JS; Hung WT; Lin CY
    J Clin Anesth; 1992; 4(2):111-5. PubMed ID: 1562333
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Potential fresh gas flow leak through Dräger Vapor 19.1 vaporizer with key-index fill port.
    Meister GC; Becker KE
    Anesthesiology; 1993 Jan; 78(1):211-2. PubMed ID: 8424562
    [No Abstract]   [Full Text] [Related]  

  • 38. [Leakage in anesthesia circuits--a comparison between 1998 and 2005 investigations].
    Tokumine J; Nitta K; Higa T; Gushiken K; Okayama H; Sugahara K
    Masui; 2007 Apr; 56(4):453-8. PubMed ID: 17441459
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Pros and cons of adding an accessory breathing system to the main circle circuit. II. Arguments against their use].
    Bourgain JL; Feiss P; Beydon L; Nivoche Y
    Ann Fr Anesth Reanim; 1998; 17(5):385-91. PubMed ID: 9750769
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Dräger ventilator-ventilates without fresh gas flow.
    Shah B; Peiris K
    Paediatr Anaesth; 2019 Jul; 29(7):768-769. PubMed ID: 30908758
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.