These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
247 related articles for article (PubMed ID: 1555964)
21. Analytical approach to heterogeneity correction factor calculation for brachytherapy. Daskalov GM; Kirov AS; Williamson JF Med Phys; 1998 May; 25(5):722-35. PubMed ID: 9608484 [TBL] [Abstract][Full Text] [Related]
22. Cluster pattern analysis of energy deposition sites for the brachytherapy sources 103Pd, 125I, 192Ir, 137Cs, and 60Co. Villegas F; Tilly N; Bäckström G; Ahnesjö A Phys Med Biol; 2014 Sep; 59(18):5531-43. PubMed ID: 25170775 [TBL] [Abstract][Full Text] [Related]
23. Ytterbium-169: calculated physical properties of a new radiation source for brachytherapy. Mason DL; Battista JJ; Barnett RB; Porter AT Med Phys; 1992; 19(3):695-703. PubMed ID: 1508110 [TBL] [Abstract][Full Text] [Related]
24. Enhanced IUdR radiosensitization by 241Am photons relative to 226Ra and 125I photons at 0.72 Gy/hr. Nath R; Bongiorni P; Rossi PI; Rockwell S Int J Radiat Oncol Biol Phys; 1990 Jun; 18(6):1377-85. PubMed ID: 2370187 [TBL] [Abstract][Full Text] [Related]
25. Dosimetric characterization of the GammaClip™ 169Yb low dose rate permanent implant brachytherapy source for the treatment of nonsmall cell lung cancer postwedge resection. Currier B; Munro JJ; Medich DC Med Phys; 2013 Aug; 40(8):080701. PubMed ID: 23927294 [TBL] [Abstract][Full Text] [Related]
26. The effect of ambient pressure on well chamber response: Monte Carlo calculated results for the HDR 1000 plus. Bohm TD; Griffin SL; DeLuca PM; DeWerd LA Med Phys; 2005 Apr; 32(4):1103-14. PubMed ID: 15895595 [TBL] [Abstract][Full Text] [Related]
27. Theoretical analysis of microdosimetric spectra and cluster formation for 103Pd and 125I photon emitters. Reniers B; Vynckier S; Verhaegen F Phys Med Biol; 2004 Aug; 49(16):3781-95. PubMed ID: 15446805 [TBL] [Abstract][Full Text] [Related]
28. MONTE CARLO-BASED INVESTIGATION OF MICRODOSIMETRIC DISTRIBUTION OF HIGH ENERGY BRACHYTHERAPY SOURCES. Chattaraj A; Selvam TP; Datta D Radiat Prot Dosimetry; 2019 Dec; 187(1):115-128. PubMed ID: 31165891 [TBL] [Abstract][Full Text] [Related]
29. The radial dose function of low-energy brachytherapy seeds in different solid phantoms: comparison between calculations with the EGSnrc and MCNP4C Monte Carlo codes and measurements. Reniers B; Verhaegen F; Vynckier S Phys Med Biol; 2004 Apr; 49(8):1569-82. PubMed ID: 15152693 [TBL] [Abstract][Full Text] [Related]
30. Tissue inhomogeneity correction for brachytherapy sources in a heterogeneous phantom with cylindrical symmetry. Meigooni AS; Nath R Med Phys; 1992; 19(2):401-7. PubMed ID: 1584139 [TBL] [Abstract][Full Text] [Related]
31. Dosimetric characteristics, air-kerma strength calibration and verification of Monte Carlo simulation for a new Ytterbium-169 brachytherapy source. Perera H; Williamson JF; Li Z; Mishra V; Meigooni AS Int J Radiat Oncol Biol Phys; 1994 Mar; 28(4):953-70. PubMed ID: 8138449 [TBL] [Abstract][Full Text] [Related]
32. Sensitivity of low energy brachytherapy Monte Carlo dose calculations to uncertainties in human tissue composition. Landry G; Reniers B; Murrer L; Lutgens L; Gurp EB; Pignol JP; Keller B; Beaulieu L; Verhaegen F Med Phys; 2010 Oct; 37(10):5188-98. PubMed ID: 21089752 [TBL] [Abstract][Full Text] [Related]
33. Dosimetric characteristics of the bests double-wall 103Pd brachytherapy source. Meigooni AS; Bharucha Z; Yoe-Sein M; Sowards K Med Phys; 2001 Dec; 28(12):2568-75. PubMed ID: 11797962 [TBL] [Abstract][Full Text] [Related]
34. Perturbation of TG-43 parameters of the brachytherapy sources under insufficient scattering materials. Zehtabian M; Sina S; Faghihi R; Meigooni A J Appl Clin Med Phys; 2013 May; 14(3):4228. PubMed ID: 23652255 [TBL] [Abstract][Full Text] [Related]
35. A Monte Carlo calculation of dosimetric parameters of 90Sr/90Y and 192Ir SS sources for intravascular brachytherapy. Wang R; Li XA Med Phys; 2000 Nov; 27(11):2528-35. PubMed ID: 11128305 [TBL] [Abstract][Full Text] [Related]
36. Influence of photon energy spectra from brachytherapy sources on Monte Carlo simulations of kerma and dose rates in water and air. Rivard MJ; Granero D; Perez-Calatayud J; Ballester F Med Phys; 2010 Feb; 37(2):869-76. PubMed ID: 20229896 [TBL] [Abstract][Full Text] [Related]
37. Microdosimetric single event spectra of Ytterbium-169 compared with commonly used brachytherapy sources and teletherapy beams. Zellmer DL; Gillin MT; Wilson JF Int J Radiat Oncol Biol Phys; 1992; 23(3):627-32. PubMed ID: 1612963 [TBL] [Abstract][Full Text] [Related]
38. Dosimetry on transverse axes of 125I and 192Ir interstitial brachytherapy sources. Nath R; Meigooni AS; Meli JA Med Phys; 1990; 17(6):1032-40. PubMed ID: 2280732 [TBL] [Abstract][Full Text] [Related]
39. A dosimetric comparison of 169Yb versus 192Ir for HDR prostate brachytherapy. Lymperopoulou G; Papagiannis P; Sakelliou L; Milickovic N; Giannouli S; Baltas D Med Phys; 2005 Dec; 32(12):3832-42. PubMed ID: 16475783 [TBL] [Abstract][Full Text] [Related]
40. EGSnrc Monte Carlo calculated dosimetry parameters for 192Ir and 169Yb brachytherapy sources. Taylor RE; Rogers DW Med Phys; 2008 Nov; 35(11):4933-44. PubMed ID: 19070227 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]