These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 15559694)

  • 1. Late vascular injury following intertrochanteric fracture reduction with sliding hip screw.
    Moreyra CE; Lavernia CJ; Cooke CC
    J Surg Orthop Adv; 2004; 13(3):170-3. PubMed ID: 15559694
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Intra pelvic total migration of sliding screw in intertrochanteric fracture.
    Bhatti A; Abbasi A
    J Coll Physicians Surg Pak; 2007 Jun; 17(6):371-3. PubMed ID: 17623593
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Intrapelvic penetration of the dynamic hip screw during removal: lesson learnt--always use a coupling screw.
    Anwar R; Boorgula V; Nicholl JE
    J Trauma; 2007 Nov; 63(5):E105-6. PubMed ID: 17514053
    [No Abstract]   [Full Text] [Related]  

  • 4. Sliding hip screw in pelvis: a rare intra-operative complication.
    Naidu Maripuri S; Debnath UK; Hemmadi S; Wilson C
    Arch Orthop Trauma Surg; 2007 Sep; 127(7):523-5. PubMed ID: 17089171
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The trochanteric nail versus the sliding hip screw for intertrochanteric hip fractures: a review of 93 cases.
    Crawford CH; Malkani AL; Cordray S; Roberts CS; Sligar W
    J Trauma; 2006 Feb; 60(2):325-8; discussion 328-9. PubMed ID: 16508490
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Iatrogenic blunt arterial injury during a hip fracture surgery.
    Bansal R; Laing PW
    Acta Orthop Belg; 2006 Jan; 72(1):96-9. PubMed ID: 16570904
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cervicocephalic medial screw migration after intertrochanteric fracture fixation, OTA/AO 31-A2, using intramedullary nail Gamma3: report of 2 cases and literature review.
    Lozano-Alvarez C; Alier A; Pelfort X; Martínez-Díaz S; Puig L
    J Orthop Trauma; 2013 Nov; 27(11):e264-7. PubMed ID: 23515128
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Technical pitfalls in the use of the sliding hip screw for fixation of intertrochanteric hip fractures.
    Rokito AS; Koval KJ; Zuckerman JD
    Contemp Orthop; 1993 Apr; 26(4):349-56. PubMed ID: 10148465
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Intramedullary versus extramedullary fixation for the treatment of intertrochanteric hip fractures.
    Baumgaertner MR; Curtin SL; Lindskog DM
    Clin Orthop Relat Res; 1998 Mar; (348):87-94. PubMed ID: 9553538
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Penetration of a sliding screw into the pelvis. A rare complication in osteosynthesis of hip fractures].
    Duun PS; Sperling KP
    Ugeskr Laeger; 1993 Aug; 155(32):2472-3. PubMed ID: 8356769
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Removal of a broken trigen intertan intertrochanteric antegrade nail.
    Zheng XL; Park YC; Kim S; An H; Yang KH
    Injury; 2017 Feb; 48(2):557-559. PubMed ID: 28041613
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Late Medial Migration of Lag Screw After Gamma3 Nailing Threatening the Internal Iliac Vessels: A Case Report.
    Pawar R; Antapur P
    JBJS Case Connect; 2020; 10(3):e19.00623. PubMed ID: 32910590
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cutaneous protrusion of a sliding compression screw. Case report.
    Shively RA
    Mo Med; 1979 Jun; 76(6):320-2, 328. PubMed ID: 470905
    [No Abstract]   [Full Text] [Related]  

  • 14. Medial migration of lag screw after gamma nailing.
    Thein E; De Cannière A; Burn A; Borens O
    Injury; 2014 Aug; 45(8):1275-9. PubMed ID: 24933440
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Mechanical failure of the intramedullary hip screw in a subtrochanteric femoral fracture.
    Rantanen J; Aro H
    J Orthop Trauma; 1996; 10(5):348-50. PubMed ID: 8814577
    [TBL] [Abstract][Full Text] [Related]  

  • 16. TRIGEN INTERTAN intramedullary nail versus sliding hip screw: a prospective, randomized multicenter study on pain, function, and complications in 684 patients with an intertrochanteric or subtrochanteric fracture and one year of follow-up.
    Matre K; Vinje T; Havelin LI; Gjertsen JE; Furnes O; Espehaug B; Kjellevold SH; Fevang JM
    J Bone Joint Surg Am; 2013 Feb; 95(3):200-8. PubMed ID: 23389782
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Sigmoid perforation after medial migration of lag screw in gamma nailing.
    Tauber M; Resch H
    Arch Orthop Trauma Surg; 2006 Mar; 126(2):118-22. PubMed ID: 16402202
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Subcapital femoral neck fracture following open reduction and internal fixation of an intertrochanteric hip fracture using a sliding screw and side plate.
    Malkani AL; Rand JA
    Orthop Rev; 1993 Apr; 22(4):469-72. PubMed ID: 8479792
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Sliding hip screw versus sliding helical blade for intertrochanteric fractures: a propensity score-matched case control study.
    Fang C; Lau TW; Wong TM; Lee HL; Leung F
    Bone Joint J; 2015 Mar; 97-B(3):398-404. PubMed ID: 25737525
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Medial migration of lag screw with intrapelvic dislocation in gamma nailing--a unique problem? A report of 2 cases.
    Lucke M; Burghardt RD; Siebenlist S; Ganslmeier A; Stöckle U
    J Orthop Trauma; 2010 Feb; 24(2):e6-e11. PubMed ID: 20101128
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.