126 related articles for article (PubMed ID: 15562084)
1. The mechanical properties of continuous spinal small-bore catheters.
Deusch E; Benrath J; Weigl L; Neumann K; Kozek-Langenecker SA
Anesth Analg; 2004 Dec; 99(6):1844-1847. PubMed ID: 15562084
[TBL] [Abstract][Full Text] [Related]
2. Strength of continuous spinal catheters.
Ley SJ; Jones BR
Anesth Analg; 1991 Oct; 73(4):394-6. PubMed ID: 1822095
[TBL] [Abstract][Full Text] [Related]
3. Tensile strength of 19- and 20-gauge arrow epidural catheters.
Tsui BCH; Finucane B
Anesth Analg; 2003 Nov; 97(5):1524-1526. PubMed ID: 14570679
[TBL] [Abstract][Full Text] [Related]
4. Comparison of Changes in Tensile Strength in Three Different Flexible Epidural Catheters Under Various Conditions.
Gonzalez Fiol A; Horvath R; Schoenberg C; Ahmed N; Dhar SK; Le V
Anesth Analg; 2016 Jul; 123(1):233-7. PubMed ID: 27111646
[TBL] [Abstract][Full Text] [Related]
5. Technical and light microscopic comparison of four different small-diameter catheters used for continuous spinal anesthesia.
Pitkänen M; Tuominen M; Rosenberg P; Wahlström T
Reg Anesth; 1992; 17(5):288-91. PubMed ID: 1419943
[TBL] [Abstract][Full Text] [Related]
6. Comparison of three catheter sets for continuous spinal anesthesia in patients undergoing total hip or knee arthroplasty.
Puolakka R; Pitkänen MT; Rosenberg PH
Reg Anesth Pain Med; 2000; 25(6):584-90. PubMed ID: 11097664
[TBL] [Abstract][Full Text] [Related]
7. The mechanical properties of intact and traumatized epidural catheters.
Ateş Y; Yücesoy CA; Unlü MA; Saygin B; Akkaş N
Anesth Analg; 2000 Feb; 90(2):393-9. PubMed ID: 10648328
[TBL] [Abstract][Full Text] [Related]
8. Technical problems associated with the use of 32-gauge and 22-gauge spinal catheters.
Silvanto M; Pitkänen M; Tuominen M; Rosenberg PH
Acta Anaesthesiol Scand; 1992 May; 36(4):295-9. PubMed ID: 1595333
[TBL] [Abstract][Full Text] [Related]
9. Technical problems with 32-gauge microcatheters in continuous spinal anaesthesia.
Standl T; Beck H
Acta Anaesthesiol Scand; 1993 Nov; 37(8):811-2. PubMed ID: 8279259
[TBL] [Abstract][Full Text] [Related]
10. Tensile strength decreases and perfusion pressure of 3-holed polyamide epidural catheters increases in long-term epidural infusion.
Kim P; Meyer U; Schüpfer G; Rukwied R; Konrad C; Gerber H
Reg Anesth Pain Med; 2011; 36(2):151-5. PubMed ID: 21270728
[TBL] [Abstract][Full Text] [Related]
11. Influence of the subarachnoid position of microcatheters on onset of analgesia and dose of plain bupivacaine 0.5% in continuous spinal anesthesia.
Standl T; Beck H
Reg Anesth; 1994; 19(4):231-6. PubMed ID: 7947422
[TBL] [Abstract][Full Text] [Related]
12. Withdrawal forces of lumbar spinal catheters: no dependence on body position.
Michalek-Sauberer A; Oehmke MJ; Scharbert G; Neumann K; Kozek-Langenecker SA; Deusch E
Br J Anaesth; 2008 Jun; 100(6):846-9. PubMed ID: 18445608
[TBL] [Abstract][Full Text] [Related]
13. Comparison of continuous spinal anaesthesia using a 32-gauge catheter with anaesthesia using a single-dose 24-gauge atraumatic needle in young patients.
de Andrés J; Bellver J; Bolinches R
Br J Anaesth; 1994 Dec; 73(6):747-50. PubMed ID: 7880657
[TBL] [Abstract][Full Text] [Related]
14. [The effect of puncture needle on the subarachnoid catheter position in continuous spinal ansthesia].
Standl T; Eckert S; Straub U
Anaesthesist; 1995 Dec; 44(12):826-30. PubMed ID: 8594956
[TBL] [Abstract][Full Text] [Related]
15. Continuous spinal anesthesia: mechanical and technical problems of catheter placement.
Möllmann M; Holst D; Lübbesmeyer H; Lawin P
Reg Anesth; 1993; 18(6 Suppl):469-72. PubMed ID: 8110649
[TBL] [Abstract][Full Text] [Related]
16. [Continuous spinal anesthesia versus continuous epidural anesthesia in surgery of the lower extremities. A prospective randomized study].
Kashanipour A; Strasser K; Klimscha W; Taslimi R; Aloy A; Semsroth M
Reg Anaesth; 1991 Aug; 14(5):83-7. PubMed ID: 1822599
[TBL] [Abstract][Full Text] [Related]
17. 32-gauge spinal catheters through 26-gauge needles.
Nagle CJ; McQuay HJ; Glynn CJ
Anaesthesia; 1991 Jul; 46(7):599. PubMed ID: 1862922
[No Abstract] [Full Text] [Related]
18. [Spinal endoscopy in the detection of problems caused by continuous spinal anesthesia].
Möllmann M; Holst D; Enk D; Filler T; Lübbesmeyer H; Deitmer T; Lawin P
Anaesthesist; 1992 Sep; 41(9):544-7. PubMed ID: 1416010
[TBL] [Abstract][Full Text] [Related]
19. Retention and strength of silicone-rubber catheters. A report of five cases of retention and analysis of catheter strength.
McKenzie JM; Flahiff CM; Nelson CL
J Bone Joint Surg Am; 1993 Oct; 75(10):1505-7. PubMed ID: 8408139
[TBL] [Abstract][Full Text] [Related]
20. An in vitro evaluation of epidural catheters: tensile strength and resistance to kinking.
Chiu JW; Goh MH
Ann Acad Med Singap; 1999 Nov; 28(6):819-23. PubMed ID: 10672395
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]