111 related articles for article (PubMed ID: 15566170)
21. A unified noise analysis for iterative image estimation.
Qi J
Phys Med Biol; 2003 Nov; 48(21):3505-19. PubMed ID: 14653559
[TBL] [Abstract][Full Text] [Related]
22. Noise properties of the EM algorithm: I. Theory.
Barrett HH; Wilson DW; Tsui BM
Phys Med Biol; 1994 May; 39(5):833-46. PubMed ID: 15552088
[TBL] [Abstract][Full Text] [Related]
23. Performance of 3DOSEM and MAP algorithms for reconstructing low count SPECT acquisitions.
Grootjans W; Meeuwis AP; Slump CH; de Geus-Oei LF; Gotthardt M; Visser EP
Z Med Phys; 2016 Dec; 26(4):311-322. PubMed ID: 26725165
[TBL] [Abstract][Full Text] [Related]
24. Improved quantitation for PET/CT image reconstruction with system modeling and anatomical priors.
Alessio AM; Kinahan PE
Med Phys; 2006 Nov; 33(11):4095-103. PubMed ID: 17153389
[TBL] [Abstract][Full Text] [Related]
25. Median-prior tomography reconstruction combined with nonlinear anisotropic diffusion filtering.
Yan J; Yu J
J Opt Soc Am A Opt Image Sci Vis; 2007 Apr; 24(4):1026-33. PubMed ID: 17361288
[TBL] [Abstract][Full Text] [Related]
26. Iterative image reconstruction using inverse fourier rebinning for fully 3-D PET.
Cho S; Li Q; Ahn S; Bai B; Leahy RM
IEEE Trans Med Imaging; 2007 Mar; 26(3):347-58. PubMed ID: 17354640
[TBL] [Abstract][Full Text] [Related]
27. Iterative threshold segmentation for PET target volume delineation.
Drever L; Roa W; McEwan A; Robinson D
Med Phys; 2007 Apr; 34(4):1253-65. PubMed ID: 17500457
[TBL] [Abstract][Full Text] [Related]
28. Regularized image reconstruction algorithms for positron emission tomography.
Chang JH; Anderson JM; Votaw JR
IEEE Trans Med Imaging; 2004 Sep; 23(9):1165-75. PubMed ID: 15377125
[TBL] [Abstract][Full Text] [Related]
29. Bayesian image reconstruction for emission tomography based on median root prior.
Alenius S; Ruotsalainen U
Eur J Nucl Med; 1997 Mar; 24(3):258-65. PubMed ID: 9143462
[TBL] [Abstract][Full Text] [Related]
30. PET transmission tomography using a novel nonlocal MRF prior.
Chen Y; Hao L; Ye X; Chen W; Luo L; Yin X
Comput Med Imaging Graph; 2009 Dec; 33(8):623-33. PubMed ID: 19717279
[TBL] [Abstract][Full Text] [Related]
31. Generalization of median root prior reconstruction.
Alenius S; Ruotsalainen U
IEEE Trans Med Imaging; 2002 Nov; 21(11):1413-20. PubMed ID: 12575878
[TBL] [Abstract][Full Text] [Related]
32. Optimisation of the OS-EM algorithm and comparison with FBP for image reconstruction on a dual-head camera: a phantom and a clinical 18F-FDG study.
Gutman F; Gardin I; Delahaye N; Rakotonirina H; Hitzel A; Manrique A; Le Guludec D; VĂ©ra P
Eur J Nucl Med Mol Imaging; 2003 Nov; 30(11):1510-9. PubMed ID: 14579091
[TBL] [Abstract][Full Text] [Related]
33. Application of discrete data consistency conditions for selecting regularization parameters in PET attenuation map reconstruction.
Panin VY; Kehren F; Hamill JJ; Michel C
Phys Med Biol; 2004 Jun; 49(11):2425-36. PubMed ID: 15248587
[TBL] [Abstract][Full Text] [Related]
34. Correction methods for random coincidences in fully 3D whole-body PET: impact on data and image quality.
Brasse D; Kinahan PE; Lartizien C; Comtat C; Casey M; Michel C
J Nucl Med; 2005 May; 46(5):859-67. PubMed ID: 15872361
[TBL] [Abstract][Full Text] [Related]
35. Convergence behavior of iterative SENSE reconstruction with non-Cartesian trajectories.
Qu P; Zhong K; Zhang B; Wang J; Shen GX
Magn Reson Med; 2005 Oct; 54(4):1040-5. PubMed ID: 16149063
[TBL] [Abstract][Full Text] [Related]
36. A general method of Bayesian estimation for parametric imaging of the brain.
Alpert NM; Yuan F
Neuroimage; 2009 May; 45(4):1183-9. PubMed ID: 19349233
[TBL] [Abstract][Full Text] [Related]
37. Maximum a posteriori reconstruction of the Patlak parametric image from sinograms in dynamic PET.
Wang G; Fu L; Qi J
Phys Med Biol; 2008 Feb; 53(3):593-604. PubMed ID: 18199904
[TBL] [Abstract][Full Text] [Related]
38. A residual correction method for high-resolution PET reconstruction with application to on-the-fly Monte Carlo based model of positron range.
Fu L; Qi J
Med Phys; 2010 Feb; 37(2):704-13. PubMed ID: 20229880
[TBL] [Abstract][Full Text] [Related]
39. Super-resolution in respiratory synchronized positron emission tomography.
Wallach D; Lamare F; Kontaxakis G; Visvikis D
IEEE Trans Med Imaging; 2012 Feb; 31(2):438-48. PubMed ID: 21997249
[TBL] [Abstract][Full Text] [Related]
40. Appropriately regularized OSEM can improve the reconstructed PET images of data with low count statistics.
Karaoglanis K; Polycarpou I; Efthimiou N; Tsoumpas C
Hell J Nucl Med; 2015; 18(2):140-5. PubMed ID: 26187214
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]