These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 15574388)

  • 1. Coil-type implantable glucose biosensor with excess enzyme loading.
    Yu B; Moussy Y; Moussy F
    Front Biosci; 2005 Jan; 10():512-20. PubMed ID: 15574388
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Glucose biosensors with enzyme entrapped in polymer coating.
    Yang S; Atanasov P; Wilkins E
    Biomed Instrum Technol; 1995; 29(2):125-33. PubMed ID: 7773322
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A long-term flexible minimally-invasive implantable glucose biosensor based on an epoxy-enhanced polyurethane membrane.
    Yu B; Long N; Moussy Y; Moussy F
    Biosens Bioelectron; 2006 Jun; 21(12):2275-82. PubMed ID: 16330201
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Study and development of multilayer needle-type enzyme-based glucose microsensors.
    Sternberg R; Barrau MB; Gangiotti L; Thévenot DR; Bindra DS; Wilson GS; Velho G; Froguel P; Reach G
    Biosensors; 1989; 4(1):27-40. PubMed ID: 2751717
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A needle-type glucose biosensor based on PANI nanofibers and PU/E-PU membrane for long-term invasive continuous monitoring.
    Fang L; Liang B; Yang G; Hu Y; Zhu Q; Ye X
    Biosens Bioelectron; 2017 Nov; 97():196-202. PubMed ID: 28599179
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fabrication of an implantable fine needle-type glucose sensor using gamma-polyglutamic acid.
    Takaoka H; Yasuzawa M
    Anal Sci; 2010; 26(5):551-5. PubMed ID: 20467129
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Highly selective needle-type glucose sensors prepared by the immobilization of glucose oxidase on γ-polyglutamic acid film.
    Yasuzawa M; Edagawa K; Matsunaga T; Takaoka H; Yabutani T
    Anal Sci; 2011; 27(3):337-40. PubMed ID: 21415521
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Poly(vinyl alcohol) : a potential matrix for glucose oxidase immobilization?
    Azila AA; Barbari T; Searson P
    Med J Malaysia; 2004 May; 59 Suppl B():51-2. PubMed ID: 15468814
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Glucose biosensor based on immobilization of glucose oxidase in platinum nanoparticles/graphene/chitosan nanocomposite film.
    Wu H; Wang J; Kang X; Wang C; Wang D; Liu J; Aksay IA; Lin Y
    Talanta; 2009 Nov; 80(1):403-6. PubMed ID: 19782243
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vitro and in vivo degradation of glucose oxidase enzyme used for an implantable glucose biosensor.
    Valdes TI; Moussy F
    Diabetes Technol Ther; 2000; 2(3):367-76. PubMed ID: 11467339
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biocompatible glucose sensor prepared by modifying protein and vinylferrocene monomer composite membrane.
    Kurita R; Tabei H; Iwasaki Y; Hayashi K; Sunagawa K; Niwa O
    Biosens Bioelectron; 2004 Oct; 20(3):518-23. PubMed ID: 15494234
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An electrochemiluminescent biosensor for glucose based on the electrochemiluminescence of luminol on the nafion/glucose oxidase/poly(nickel(II)tetrasulfophthalocyanine)/multi-walled carbon nanotubes modified electrode.
    Qiu B; Lin Z; Wang J; Chen Z; Chen J; Chen G
    Talanta; 2009 Apr; 78(1):76-80. PubMed ID: 19174206
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A potentially implantable enzyme electrode for amperometric measurement of glucose.
    Kerner W; Zier H; Steinbach G; Brückel J; Pfeiffer EF; Weiss T; Cammann K; Planck H
    Horm Metab Res Suppl; 1988; 20():8-13. PubMed ID: 3248792
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Amperometric glucose biosensor based on layer-by-layer assembly of multilayer films composed of chitosan, gold nanoparticles and glucose oxidase modified Pt electrode.
    Wu BY; Hou SH; Yin F; Li J; Zhao ZX; Huang JD; Chen Q
    Biosens Bioelectron; 2007 Jan; 22(6):838-44. PubMed ID: 16675215
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Optimisation of the composition of a screen-printed acrylate polymer enzyme layer with respect to an improved selectivity and stability of enzyme electrodes.
    Mersal GA; Khodari M; Bilitewski U
    Biosens Bioelectron; 2004 Sep; 20(2):305-14. PubMed ID: 15308235
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development of glucose amperometric biosensor based on a novel attractive enzyme immobilization matrix: amino derivative of thiacalix[4]arene.
    Chen M; Zhang W; Jiang R; Diao G
    Anal Chim Acta; 2011 Feb; 687(2):177-83. PubMed ID: 21277420
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Direct electron transfer of glucose oxidase and dual hydrogen peroxide and glucose detection based on water-dispersible carbon nanotubes derivative.
    Chen HC; Tu YM; Hou CC; Lin YC; Chen CH; Yang KH
    Anal Chim Acta; 2015 Mar; 867():83-91. PubMed ID: 25813031
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A new modified conducting carbon composite electrode as sensor for ascorbate and biosensor for glucose.
    Barsan MM; Brett CM
    Bioelectrochemistry; 2009 Sep; 76(1-2):135-40. PubMed ID: 19349215
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Study of glucose biosensor lifetime improvement in 37°C serum based on PANI enzyme immobilization and PLGA biodegradable membrane.
    Fang L; Liang B; Yang G; Hu Y; Zhu Q; Ye X
    Biosens Bioelectron; 2014 Jun; 56():91-6. PubMed ID: 24480128
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An investigation of long-term performance of minimally invasive glucose biosensors.
    Yu B; Ju Y; West L; Moussy Y; Moussy F
    Diabetes Technol Ther; 2007 Jun; 9(3):265-75. PubMed ID: 17561797
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.