These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 15578205)

  • 1. Non-linear cardiac output dynamics during ramp-incremental cycle ergometry.
    Stringer WW; Whipp BJ; Wasserman K; Pórszász J; Christenson P; French WJ
    Eur J Appl Physiol; 2005 Mar; 93(5-6):634-9. PubMed ID: 15578205
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Cardiac output and oxygen release during very high-intensity exercise performed until exhaustion.
    Richard R; Lonsdorfer-Wolf E; Dufour S; Doutreleau S; Oswald-Mammosser M; Billat VL; Lonsdorfer J
    Eur J Appl Physiol; 2004 Oct; 93(1-2):9-18. PubMed ID: 15278352
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Reproducibility of the exponential rise technique of CO(2) rebreathing for measuring P(v)CO(2) and C(v)CO(2 )to non-invasively estimate cardiac output during incremental, maximal treadmill exercise.
    Cade WT; Nabar SR; Keyser RE
    Eur J Appl Physiol; 2004 May; 91(5-6):669-76. PubMed ID: 14652761
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dynamics of noninvasively estimated microvascular O2 extraction during ramp exercise.
    Ferreira LF; Koga S; Barstow TJ
    J Appl Physiol (1985); 2007 Dec; 103(6):1999-2004. PubMed ID: 17823295
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Linear and non-linear contributions to oxygen transport and utilization during moderate random exercise in humans.
    Beltrame T; Hughson RL
    Exp Physiol; 2017 May; 102(5):563-577. PubMed ID: 28240387
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Influence of expiratory flow-limitation during exercise on systemic oxygen delivery in humans.
    Aliverti A; Dellacà RL; Lotti P; Bertini S; Duranti R; Scano G; Heyman J; Lo Mauro A; Pedotti A; Macklem PT
    Eur J Appl Physiol; 2005 Oct; 95(2-3):229-42. PubMed ID: 16086145
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Clinical application of cardiac output during ramp exercise calculated using the Fick equation--comparison with the 2-stage bicycle ergometer exercise protocol in the supine position.
    Yamabe H; Itho K; Yasaka Y; Yokoyama M
    Jpn Circ J; 1997 Jun; 61(6):488-94. PubMed ID: 9225194
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fatigue responses in exercise under control of VO2.
    Lepretre PM; Lopes P; Koralsztein JP; Billat V
    Int J Sports Med; 2008 Mar; 29(3):199-205. PubMed ID: 17879879
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Simultaneous determination of the kinetics of cardiac output, systemic O(2) delivery, and lung O(2) uptake at exercise onset in men.
    Lador F; Azabji Kenfack M; Moia C; Cautero M; Morel DR; Capelli C; Ferretti G
    Am J Physiol Regul Integr Comp Physiol; 2006 Apr; 290(4):R1071-9. PubMed ID: 16239373
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Increased cardiac output elicits higher V̇O2max in response to self-paced exercise.
    Astorino TA; McMillan DW; Edmunds RM; Sanchez E
    Appl Physiol Nutr Metab; 2015 Mar; 40(3):223-9. PubMed ID: 25682980
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Influence of work rate on dynamics of O2 uptake under hypoxic conditions in humans.
    Hotta N; Abe D; Yoshida T; Aoki T; Fukuoka Y
    J Sports Med Phys Fitness; 2008 Jun; 48(2):129-37. PubMed ID: 18427405
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Estimating exercise stroke volume from asymptotic oxygen pulse in humans.
    Whipp BJ; Higgenbotham MB; Cobb FC
    J Appl Physiol (1985); 1996 Dec; 81(6):2674-9. PubMed ID: 9018521
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Relationship between cardiac output and oxygen consumption during upright cycle exercise in healthy humans.
    Beck KC; Randolph LN; Bailey KR; Wood CM; Snyder EM; Johnson BD
    J Appl Physiol (1985); 2006 Nov; 101(5):1474-80. PubMed ID: 16873603
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Non-linear relationships between central cardiovascular variables and VO2 during incremental cycling exercise in endurance-trained individuals.
    Vella CA; Robergs RA
    J Sports Med Phys Fitness; 2005 Dec; 45(4):452-9. PubMed ID: 16446675
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measurement of cardiac output by CO2 rebreathing in unsteady state exercise.
    McKelvie RS; Heigenhauser GJ; Jones NL
    Chest; 1987 Nov; 92(5):777-82. PubMed ID: 3117498
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Non-invasive measurement of stroke volume during exercise in heart failure patients.
    Agostoni PG; Wasserman K; Perego GB; Guazzi M; Cattadori G; Palermo P; Lauri G; Marenzi G
    Clin Sci (Lond); 2000 May; 98(5):545-51. PubMed ID: 10781385
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Influence of muscle metabolic heterogeneity in determining the V̇o2p kinetic response to ramp-incremental exercise.
    Keir DA; Benson AP; Love LK; Robertson TC; Rossiter HB; Kowalchuk JM
    J Appl Physiol (1985); 2016 Mar; 120(5):503-13. PubMed ID: 26679614
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cardiac output estimated noninvasively from oxygen uptake during exercise.
    Stringer WW; Hansen JE; Wasserman K
    J Appl Physiol (1985); 1997 Mar; 82(3):908-12. PubMed ID: 9074981
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Reference Values for Peak Exercise Cardiac Output in Healthy Individuals.
    Agostoni P; Vignati C; Gentile P; Boiti C; Farina S; Salvioni E; Mapelli M; Magrì D; Paolillo S; Corrieri N; Sinagra G; Cattadori G
    Chest; 2017 Jun; 151(6):1329-1337. PubMed ID: 28108178
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The maximally attainable VO2 during exercise in humans: the peak vs. maximum issue.
    Day JR; Rossiter HB; Coats EM; Skasick A; Whipp BJ
    J Appl Physiol (1985); 2003 Nov; 95(5):1901-7. PubMed ID: 12857763
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.