BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

621 related articles for article (PubMed ID: 15580587)

  • 1. Continuous perfusion microfluidic cell culture array for high-throughput cell-based assays.
    Hung PJ; Lee PJ; Sabounchi P; Lin R; Lee LP
    Biotechnol Bioeng; 2005 Jan; 89(1):1-8. PubMed ID: 15580587
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A novel high aspect ratio microfluidic design to provide a stable and uniform microenvironment for cell growth in a high throughput mammalian cell culture array.
    Hung PJ; Lee PJ; Sabounchi P; Aghdam N; Lin R; Lee LP
    Lab Chip; 2005 Jan; 5(1):44-8. PubMed ID: 15616739
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A high throughput perfusion-based microbioreactor platform integrated with pneumatic micropumps for three-dimensional cell culture.
    Wu MH; Huang SB; Cui Z; Cui Z; Lee GB
    Biomed Microdevices; 2008 Apr; 10(2):309-19. PubMed ID: 18026840
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An integrated microfluidic system for long-term perfusion culture and on-line monitoring of intestinal tissue models.
    Kimura H; Yamamoto T; Sakai H; Sakai Y; Fujii T
    Lab Chip; 2008 May; 8(5):741-6. PubMed ID: 18432344
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Microfluidic PDMS (polydimethylsiloxane) bioreactor for large-scale culture of hepatocytes.
    Leclerc E; Sakai Y; Fujii T
    Biotechnol Prog; 2004; 20(3):750-5. PubMed ID: 15176878
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A microfluidic cell culture platform for real-time cellular imaging.
    Hsieh CC; Huang SB; Wu PC; Shieh DB; Lee GB
    Biomed Microdevices; 2009 Aug; 11(4):903-13. PubMed ID: 19370417
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Self-loading and cell culture in one layer microfluidic devices.
    Wang L; Ni XF; Luo CX; Zhang ZL; Pang DW; Chen Y
    Biomed Microdevices; 2009 Jun; 11(3):679-84. PubMed ID: 19130238
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pressure-driven perfusion culture microchamber array for a parallel drug cytotoxicity assay.
    Sugiura S; Edahiro J; Kikuchi K; Sumaru K; Kanamori T
    Biotechnol Bioeng; 2008 Aug; 100(6):1156-65. PubMed ID: 18553395
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A microfluidic platform for 3-dimensional cell culture and cell-based assays.
    Kim MS; Yeon JH; Park JK
    Biomed Microdevices; 2007 Feb; 9(1):25-34. PubMed ID: 17103048
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A microfluidic cell array with individually addressable culture chambers.
    Wang HY; Bao N; Lu C
    Biosens Bioelectron; 2008 Dec; 24(4):613-7. PubMed ID: 18635348
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Microfluidic arrays for logarithmically perfused embryonic stem cell culture.
    Kim L; Vahey MD; Lee HY; Voldman J
    Lab Chip; 2006 Mar; 6(3):394-406. PubMed ID: 16511623
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Nanoliter scale microbioreactor array for quantitative cell biology.
    Lee PJ; Hung PJ; Rao VM; Lee LP
    Biotechnol Bioeng; 2006 May; 94(1):5-14. PubMed ID: 16315325
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of high throughput optical sensor array for on-line pH monitoring in micro-scale cell culture environment.
    Wu MH; Lin JL; Wang J; Cui Z; Cui Z
    Biomed Microdevices; 2009 Feb; 11(1):265-73. PubMed ID: 18830696
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A self-contained microfluidic cell culture system.
    Zhang B; Kim MC; Thorsen T; Wang Z
    Biomed Microdevices; 2009 Dec; 11(6):1233-7. PubMed ID: 19629698
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dynamic single cell culture array.
    Di Carlo D; Wu LY; Lee LP
    Lab Chip; 2006 Nov; 6(11):1445-9. PubMed ID: 17066168
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Microfluidic stickers for cell- and tissue-based assays in microchannels.
    Morel M; Bartolo D; Galas JC; Dahan M; Studer V
    Lab Chip; 2009 Apr; 9(7):1011-3. PubMed ID: 19294316
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An integrated microfluidic culture device for quantitative analysis of human embryonic stem cells.
    Kamei K; Guo S; Yu ZT; Takahashi H; Gschweng E; Suh C; Wang X; Tang J; McLaughlin J; Witte ON; Lee KB; Tseng HR
    Lab Chip; 2009 Feb; 9(4):555-63. PubMed ID: 19190791
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Continuously perfused, non-cross-contaminating microfluidic chamber array for studying cellular responses to orthogonal combinations of matrix and soluble signals.
    Park ES; Brown AC; DiFeo MA; Barker TH; Lu H
    Lab Chip; 2010 Mar; 10(5):571-80. PubMed ID: 20162232
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Microfabricated platform for studying stem cell fates.
    Chin VI; Taupin P; Sanga S; Scheel J; Gage FH; Bhatia SN
    Biotechnol Bioeng; 2004 Nov; 88(3):399-415. PubMed ID: 15486946
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A microfluidic platform for sequential ligand labeling and cell binding analysis.
    Sui G; Lee CC; Kamei K; Li HJ; Wang JY; Wang J; Herschman HR; Tseng HR
    Biomed Microdevices; 2007 Jun; 9(3):301-5. PubMed ID: 17195108
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 32.