131 related articles for article (PubMed ID: 15580846)
1. Linear accelerator output variability.
Luketina IA; Greig L
Australas Phys Eng Sci Med; 2004 Sep; 27(3):155-9. PubMed ID: 15580846
[TBL] [Abstract][Full Text] [Related]
2. A multi-institutional evaluation of machine performance check system on treatment beam output and symmetry using statistical process control.
Binny D; Aland T; Archibald-Heeren BR; Trapp JV; Kairn T; Crowe SB
J Appl Clin Med Phys; 2019 Mar; 20(3):71-80. PubMed ID: 30786139
[TBL] [Abstract][Full Text] [Related]
3. Review of the energy check of an electron-only linear accelerator over a 6 year period: sensitivity of the technique to energy shift.
Biggs PJ
Med Phys; 2003 Apr; 30(4):635-9. PubMed ID: 12722815
[TBL] [Abstract][Full Text] [Related]
4. Dosimetric quality control measurements of 60Co teletherapy units in Nigeria.
Farai IP; Obed RI
Health Phys; 2004 May; 86(5):493-6. PubMed ID: 15083144
[TBL] [Abstract][Full Text] [Related]
5. Proposed definitions for isodose flatness and symmetry in clinical radiotherapy beams.
Galiano E; Joly T; Wiebe F
Appl Radiat Isot; 2004 Dec; 61(6):1361-6. PubMed ID: 15388134
[TBL] [Abstract][Full Text] [Related]
6. Technical note: output and energy fluctuations of the tomotherapy Hi-Art helical tomotherapy system.
Mahan SL; Chase DJ; Ramsey CR
Med Phys; 2004 Jul; 31(7):2119-20. PubMed ID: 15305465
[TBL] [Abstract][Full Text] [Related]
7. The linear accelerator mechanical and radiation isocentre assessment with an electronic portal imaging device (EPID).
Liu G; van Doorn T; Bezak E
Australas Phys Eng Sci Med; 2004 Sep; 27(3):111-7. PubMed ID: 15580840
[TBL] [Abstract][Full Text] [Related]
8. An automated procedure for the quality assurance of electron beam output and energy.
Woo MK; Videla NG
Med Phys; 2004 May; 31(5):972-4. PubMed ID: 15191280
[TBL] [Abstract][Full Text] [Related]
9. Retrospective analysis of linear accelerator output constancy checks using process control techniques.
Sanghangthum T; Suriyapee S; Srisatit S; Pawlicki T
J Appl Clin Med Phys; 2013 Jan; 14(1):4032. PubMed ID: 23318390
[TBL] [Abstract][Full Text] [Related]
10. Factor 10 Expedience of Monthly Linac Quality Assurance via an Ion Chamber Array and Automation Scripts.
Skinner LB; Yang Y; Hsu A; Xing L; Yu AS; Niedermayr T
Technol Cancer Res Treat; 2019; 18():1533033819876897. PubMed ID: 31707931
[TBL] [Abstract][Full Text] [Related]
11. Monitoring Daily QA 3 constancy for routine quality assurance on linear accelerators.
Binny D; Lancaster CM; Kairn T; Trapp JV; Crowe SB
Phys Med; 2016 Nov; 32(11):1479-1487. PubMed ID: 27839928
[TBL] [Abstract][Full Text] [Related]
12. Comprehensive quality assurance for stereotactic radiosurgery treatments.
Ramaseshan R; Heydarian M
Phys Med Biol; 2003 Jul; 48(14):N199-205. PubMed ID: 12894984
[TBL] [Abstract][Full Text] [Related]
13. The use of a commercial QA device for daily output check of a helical tomotherapy unit.
Alaei P; Hui SK; Higgins PD; Gerbi BJ
Med Phys; 2006 Oct; 33(10):3680-2. PubMed ID: 17089833
[TBL] [Abstract][Full Text] [Related]
14. Stability of a mobile electron linear accelerator system for intraoperative radiation therapy.
Beddar AS
Med Phys; 2005 Oct; 32(10):3128-31. PubMed ID: 16279065
[TBL] [Abstract][Full Text] [Related]
15. Linear-accelerator X-ray output: a multicentre chamber-based intercomparison study in Australia and New Zealand.
Ebert MA; Howlett SJ; Harrison K; Cornes D; Hamilton CS; Denham JD
Australas Phys Eng Sci Med; 2008 Dec; 31(4):268-79. PubMed ID: 19239053
[TBL] [Abstract][Full Text] [Related]
16. Commissioning of a medical accelerator photon beam Monte Carlo simulation using wide-field profiles.
Pena J; Franco L; Gómez F; Iglesias A; Lobato R; Mosquera J; Pazos A; Pardo J; Pombar M; Rodríguez A; Sendón J
Phys Med Biol; 2004 Nov; 49(21):4929-42. PubMed ID: 15584528
[TBL] [Abstract][Full Text] [Related]
17. Linear accelerator calibration monitor with a memory.
Dixon RL; Ekstrand KE
Med Phys; 1979; 6(5):436-40. PubMed ID: 114745
[TBL] [Abstract][Full Text] [Related]
18. Use of an amorphous silicon electronic portal imaging device for multileaf collimator quality control and calibration.
Baker SJ; Budgell GJ; MacKay RI
Phys Med Biol; 2005 Apr; 50(7):1377-92. PubMed ID: 15798330
[TBL] [Abstract][Full Text] [Related]
19. Evaluation of the TrueBeam machine performance check (MPC) beam constancy checks for flattened and flattening filter-free (FFF) photon beams.
Barnes MP; Greer PB
J Appl Clin Med Phys; 2017 Jan; 18(1):139-150. PubMed ID: 28291921
[TBL] [Abstract][Full Text] [Related]
20. Monitoring linear accelerator output constancy using the PTW Linacheck.
McDermott GM; Buckle AH
Med Dosim; 2011; 36(1):71-4. PubMed ID: 20346645
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]