These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 15582951)

  • 1. Transmission electron microscopy on thin film of high density magnetic composite prepared by FIB method.
    Kobayashi Y; Park YG; Shindo D; Tajima S
    J Electron Microsc (Tokyo); 2004; 53(5):485-7. PubMed ID: 15582951
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Electron holography study of remanence states in exchange-biased MnPd/Fe bilayers grown epitaxially on MgO(001).
    Jeong JS; Akase Z; Shindo D; Zhan QF; Krishnan KM
    J Electron Microsc (Tokyo); 2011; 60(3):235-42. PubMed ID: 21474493
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Side-milling technique of preparing device cross-sections for electron holography based on a focused ion beam micro-sampling system.
    Wang Z; Kato T; Hirayama T
    J Electron Microsc (Tokyo); 2004; 53(5):489-91. PubMed ID: 15582952
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Application of focused ion beam techniques and transmission electron microscopy to thin-film transistor failure analysis.
    Tsuji S; Tsujimoto K; Kuroda K; Saka H
    J Electron Microsc (Tokyo); 2004; 53(5):465-70. PubMed ID: 15582948
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Focused ion beam fabrication of field-ion microscope specimens from mechanically milled pearlitic steel powder.
    Ohsaki S; Hono K; Hidaka H; Takaki S
    J Electron Microsc (Tokyo); 2004; 53(5):523-5. PubMed ID: 15582960
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Electron holography of magnetic field generated by a magnetic recording head.
    Goto T; Jeong JS; Xia W; Akase Z; Shindo D; Hirata K
    Microscopy (Oxf); 2013 Jun; 62(3):383-9. PubMed ID: 23291267
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Investigation of (Fe,Co)NbB-Based Nanocrystalline Soft Magnetic Alloys by Lorentz Microscopy and Off-Axis Electron Holography.
    Zheng C; Kirmse H; Long J; Laughlin DE; McHenry ME; Neumann W
    Microsc Microanal; 2015 Apr; 21(2):498-509. PubMed ID: 25404008
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Lorentz microscopy observation of vortices in high-Tc superconductors using a 1-MV field emission transmission electron microscope.
    Harada K
    Microscopy (Oxf); 2013 Jun; 62 Suppl 1():S3-15. PubMed ID: 23549454
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Specimen preparation for high-resolution transmission electron microscopy using focused ion beam and Ar ion milling.
    Sasaki H; Matsuda T; Kato T; Muroga T; Iijima Y; Saitoh T; Iwase F; Yamada Y; Izumi T; Shiohara Y; Hirayama T
    J Electron Microsc (Tokyo); 2004; 53(5):497-500. PubMed ID: 15582954
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A review of focused ion beam technology and its applications in transmission electron microscopy.
    Sugiyama M; Sigesato G
    J Electron Microsc (Tokyo); 2004; 53(5):527-36. PubMed ID: 15582961
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reducing focused ion beam damage to transmission electron microscopy samples.
    Kato NI
    J Electron Microsc (Tokyo); 2004; 53(5):451-8. PubMed ID: 15582946
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of TEM samples of an Mg-Al alloy prepared using FIB milling at the operating voltages of 10 kV and 40 kV.
    Kamino T; Yaguchi T; Kuroda Y; Ohnishi T; Ishitani T; Miyahara Y; Horita Z
    J Electron Microsc (Tokyo); 2004; 53(5):459-63. PubMed ID: 15582947
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Direct observation of dopant distribution in GaAs compound semiconductors using phase-shifting electron holography and Lorentz microscopy.
    Sasaki H; Otomo S; Minato R; Yamamoto K; Hirayama T
    Microscopy (Oxf); 2014 Jun; 63(3):235-42. PubMed ID: 24706942
    [TBL] [Abstract][Full Text] [Related]  

  • 14. FIB and TEM observations of defects in hot-dip zinc coatings.
    Hong MH; Saka H
    J Electron Microsc (Tokyo); 2004; 53(5):545-52. PubMed ID: 15582963
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A site-specific focused-ion-beam lift-out method for cryo Transmission Electron Microscopy.
    Rubino S; Akhtar S; Melin P; Searle A; Spellward P; Leifer K
    J Struct Biol; 2012 Dec; 180(3):572-6. PubMed ID: 23000702
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Focused ion beam milling and ultramicrotomy of mineralised ivory dentine for analytical transmission electron microscopy.
    Jantou V; Turmaine M; West GD; Horton MA; McComb DW
    Micron; 2009 Jun; 40(4):495-501. PubMed ID: 19157888
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Location specific in situ TEM straining specimens made using FIB.
    Field RD; Papin PA
    Ultramicroscopy; 2004 Dec; 102(1):23-6. PubMed ID: 15556697
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ultrasoft magnetic films investigated with Lorentz tranmission electron microscopy and electron holography.
    De Hosson JT; Chechenin NG; Alsem DH; Vystavel T; Kooi BJ; Chezan AR; Boerma DO
    Microsc Microanal; 2002 Aug; 8(4):274-87. PubMed ID: 12533225
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A method for multidirectional TEM observation of a specific site at atomic resolution.
    Kamino T; Yaguchi T; Konno M; Ohnishi T; Ishitani T
    J Electron Microsc (Tokyo); 2004; 53(6):583-8. PubMed ID: 15582970
    [TBL] [Abstract][Full Text] [Related]  

  • 20. 2D-mapping of dopant distribution in deep sub micron CMOS devices by electron holography using adapted FIB-preparation.
    Lenk A; Lichte H; Muehle U
    J Electron Microsc (Tokyo); 2005 Aug; 54(4):351-9. PubMed ID: 16123059
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.