These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 15582956)

  • 1. HVEM study of crack-tip dislocations in Si crystals prepared by FIB and twin-blade cutting method.
    Tanaka M; Higashida K; Fukui T; Yokote T
    J Electron Microsc (Tokyo); 2004; 53(5):505-9. PubMed ID: 15582956
    [TBL] [Abstract][Full Text] [Related]  

  • 2. HVEM characterization of crack tip dislocations in silicon crystals.
    Tanaka M; Higashida K
    J Electron Microsc (Tokyo); 2004; 53(4):353-60. PubMed ID: 15582934
    [TBL] [Abstract][Full Text] [Related]  

  • 3. 3-D structures of crack-tip dislocations and their shielding effect revealed by electron tomography.
    Tanaka M; Honda M; Sadamatsu S; Higashida K
    J Electron Microsc (Tokyo); 2010 Aug; 59 Suppl 1():S55-60. PubMed ID: 20551448
    [TBL] [Abstract][Full Text] [Related]  

  • 4. 3D analysis of cracking behaviour under indentation in ion-irradiated beta-SiC.
    Park KH; Kishimoto H; Kohyama A
    J Electron Microsc (Tokyo); 2004; 53(5):511-3. PubMed ID: 15582957
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Microstructural analysis of the deformation range under nano-indentation in beta-SiC.
    Kishimoto H; Park KH; Kondo S; Ozawa K; Kohyama A
    J Electron Microsc (Tokyo); 2004; 53(5):515-7. PubMed ID: 15582958
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Application of focused ion beam techniques and transmission electron microscopy to thin-film transistor failure analysis.
    Tsuji S; Tsujimoto K; Kuroda K; Saka H
    J Electron Microsc (Tokyo); 2004; 53(5):465-70. PubMed ID: 15582948
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Crack tip shielding observed with high-resolution transmission electron microscopy.
    Adhika DR; Tanaka M; Daio T; Higashida K
    Microscopy (Oxf); 2015 Oct; 64(5):335-40. PubMed ID: 26115957
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Specimen preparation for high-resolution transmission electron microscopy using focused ion beam and Ar ion milling.
    Sasaki H; Matsuda T; Kato T; Muroga T; Iijima Y; Saitoh T; Iwase F; Yamada Y; Izumi T; Shiohara Y; Hirayama T
    J Electron Microsc (Tokyo); 2004; 53(5):497-500. PubMed ID: 15582954
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evolution of residual stress and crack morphologies during 3D FIB tomographic analysis of alumina.
    Elfallagh F; Inkson BJ
    J Microsc; 2008 May; 230(Pt 2):240-51. PubMed ID: 18445153
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reducing focused ion beam damage to transmission electron microscopy samples.
    Kato NI
    J Electron Microsc (Tokyo); 2004; 53(5):451-8. PubMed ID: 15582946
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Residual micro-stress distributions in heat-pressed ceramic on zirconia and porcelain-fused to metal systems: Analysis by FIB-DIC ring-core method and correlation with fracture toughness.
    Sebastiani M; Massimi F; Merlati G; Bemporad E
    Dent Mater; 2015 Nov; 31(11):1396-405. PubMed ID: 26365988
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Applications of the FIB lift-out technique for TEM specimen preparation.
    Giannuzzi LA; Drown JL; Brown SR; Irwin RB; Stevie FA
    Microsc Res Tech; 1998 May; 41(4):285-90. PubMed ID: 9633946
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Application of FIB with micro pick-up to microstructural study of irradiated SiC/SiC composites.
    Ozawa K; Kondo S; Kishimoto H; Kohyama A
    J Electron Microsc (Tokyo); 2004; 53(5):519-21. PubMed ID: 15582959
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Post-thinning technique for a lifted-out membrane.
    Sadayama S; Sugiyama Y; Iwasaki K; Yasaka A
    J Electron Microsc (Tokyo); 2004; 53(5):493-6. PubMed ID: 15582953
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A site-specific focused-ion-beam lift-out method for cryo Transmission Electron Microscopy.
    Rubino S; Akhtar S; Melin P; Searle A; Spellward P; Leifer K
    J Struct Biol; 2012 Dec; 180(3):572-6. PubMed ID: 23000702
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A method for multidirectional TEM observation of a specific site at atomic resolution.
    Kamino T; Yaguchi T; Konno M; Ohnishi T; Ishitani T
    J Electron Microsc (Tokyo); 2004; 53(6):583-8. PubMed ID: 15582970
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Preparation of transmission electron microscopy cross-section specimens of crack tips using focused ion beam milling.
    Huang YZ; Lozano-Perez S; Langford RM; Titchmarsh JM; Jenkins ML
    J Microsc; 2002 Aug; 207(Pt 2):129-36. PubMed ID: 12180958
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Location specific in situ TEM straining specimens made using FIB.
    Field RD; Papin PA
    Ultramicroscopy; 2004 Dec; 102(1):23-6. PubMed ID: 15556697
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Side-milling technique of preparing device cross-sections for electron holography based on a focused ion beam micro-sampling system.
    Wang Z; Kato T; Hirayama T
    J Electron Microsc (Tokyo); 2004; 53(5):489-91. PubMed ID: 15582952
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Method for Cross-sectional Transmission Electron Microscopy Specimen Preparation of Composite Materials Using a Dedicated Focused Ion Beam System.
    Yaguchi T; Kamino T; Ishitani T; Urao R
    Microsc Microanal; 1999 Sep; 5(5):365-370. PubMed ID: 10473682
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.