These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

220 related articles for article (PubMed ID: 15582961)

  • 1. A review of focused ion beam technology and its applications in transmission electron microscopy.
    Sugiyama M; Sigesato G
    J Electron Microsc (Tokyo); 2004; 53(5):527-36. PubMed ID: 15582961
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reducing focused ion beam damage to transmission electron microscopy samples.
    Kato NI
    J Electron Microsc (Tokyo); 2004; 53(5):451-8. PubMed ID: 15582946
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Improvements in performance of focused ion beam cross-sectioning: aspects of ion-sample interaction.
    Ishitani T; Umemura K; Ohnishi T; Yaguchi T; Kamino T
    J Electron Microsc (Tokyo); 2004; 53(5):443-9. PubMed ID: 15582945
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Specimen preparation for high-resolution transmission electron microscopy using focused ion beam and Ar ion milling.
    Sasaki H; Matsuda T; Kato T; Muroga T; Iijima Y; Saitoh T; Iwase F; Yamada Y; Izumi T; Shiohara Y; Hirayama T
    J Electron Microsc (Tokyo); 2004; 53(5):497-500. PubMed ID: 15582954
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Focused ion beam milling and ultramicrotomy of mineralised ivory dentine for analytical transmission electron microscopy.
    Jantou V; Turmaine M; West GD; Horton MA; McComb DW
    Micron; 2009 Jun; 40(4):495-501. PubMed ID: 19157888
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A site-specific focused-ion-beam lift-out method for cryo Transmission Electron Microscopy.
    Rubino S; Akhtar S; Melin P; Searle A; Spellward P; Leifer K
    J Struct Biol; 2012 Dec; 180(3):572-6. PubMed ID: 23000702
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Applications of the FIB lift-out technique for TEM specimen preparation.
    Giannuzzi LA; Drown JL; Brown SR; Irwin RB; Stevie FA
    Microsc Res Tech; 1998 May; 41(4):285-90. PubMed ID: 9633946
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Side-milling technique of preparing device cross-sections for electron holography based on a focused ion beam micro-sampling system.
    Wang Z; Kato T; Hirayama T
    J Electron Microsc (Tokyo); 2004; 53(5):489-91. PubMed ID: 15582952
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A study of the damage on FIB-prepared TEM samples of AlxGa1-xAs.
    Yabuuchi Y; Tametou S; Okano T; Inazato S; Sadayama S; Yamamoto Y; Iwasaki K; Sugiyama Y
    J Electron Microsc (Tokyo); 2004; 53(5):471-7. PubMed ID: 15582949
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of TEM samples of an Mg-Al alloy prepared using FIB milling at the operating voltages of 10 kV and 40 kV.
    Kamino T; Yaguchi T; Kuroda Y; Ohnishi T; Ishitani T; Miyahara Y; Horita Z
    J Electron Microsc (Tokyo); 2004; 53(5):459-63. PubMed ID: 15582947
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Two-dimensional and 3-dimensional analysis of bone/dental implant interfaces with the use of focused ion beam and electron microscopy.
    Giannuzzi LA; Phifer D; Giannuzzi NJ; Capuano MJ
    J Oral Maxillofac Surg; 2007 Apr; 65(4):737-47. PubMed ID: 17368372
    [TBL] [Abstract][Full Text] [Related]  

  • 12. 3D imaging of cells and tissues by focused ion beam/scanning electron microscopy (FIB/SEM).
    Drobne D
    Methods Mol Biol; 2013; 950():275-92. PubMed ID: 23086881
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Microsampling technique for EBSP inspection on the cross-sections of copper trench lines in ULSIs.
    Hirose Y; Hashikawa N; Fukumoto K; Mashiko Y
    J Electron Microsc (Tokyo); 2004; 53(5):567-70. PubMed ID: 15582967
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Application of focused ion beam techniques and transmission electron microscopy to thin-film transistor failure analysis.
    Tsuji S; Tsujimoto K; Kuroda K; Saka H
    J Electron Microsc (Tokyo); 2004; 53(5):465-70. PubMed ID: 15582948
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Cryo-focused-ion-beam applications in structural biology.
    Rigort A; Plitzko JM
    Arch Biochem Biophys; 2015 Sep; 581():122-30. PubMed ID: 25703192
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Location specific in situ TEM straining specimens made using FIB.
    Field RD; Papin PA
    Ultramicroscopy; 2004 Dec; 102(1):23-6. PubMed ID: 15556697
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In situ hydride formation in titanium during focused ion milling.
    Ding R; Jones IP
    J Electron Microsc (Tokyo); 2011; 60(1):1-9. PubMed ID: 20871111
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of neon focused ion beam milling for TEM sample preparation.
    Pekin TC; Allen FI; Minor AM
    J Microsc; 2016 Oct; 264(1):59-63. PubMed ID: 27172066
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Thinning of large mammalian cells for cryo-TEM characterization by cryo-FIB milling.
    Strunk KM; Wang K; Ke D; Gray JL; Zhang P
    J Microsc; 2012 Sep; 247(3):220-7. PubMed ID: 22906009
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Surface damage induced by FIB milling and imaging of biological samples is controllable.
    Drobne D; Milani M; Leser V; Tatti F
    Microsc Res Tech; 2007 Oct; 70(10):895-903. PubMed ID: 17661360
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.