These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
290 related articles for article (PubMed ID: 15585228)
1. Carbon plasma immersion ion implantation of nickel-titanium shape memory alloys. Poon RW; Yeung KW; Liu XY; Chu PK; Chung CY; Lu WW; Cheung KM; Chan D Biomaterials; 2005 May; 26(15):2265-72. PubMed ID: 15585228 [TBL] [Abstract][Full Text] [Related]
2. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials. Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246 [TBL] [Abstract][Full Text] [Related]
3. Corrosion resistance, surface mechanical properties, and cytocompatibility of plasma immersion ion implantation-treated nickel-titanium shape memory alloys. Yeung KW; Poon RW; Liu XY; Ho JP; Chung CY; Chu PK; Lu WW; Chan D; Cheung KM J Biomed Mater Res A; 2005 Nov; 75(2):256-67. PubMed ID: 16078209 [TBL] [Abstract][Full Text] [Related]
4. Investigation of nickel suppression and cytocompatibility of surface-treated nickel-titanium shape memory alloys by using plasma immersion ion implantation. Yeung KW; Poon RW; Liu XY; Ho JP; Chung CY; Chu PK; Lu WW; Chan D; Cheung KM J Biomed Mater Res A; 2005 Mar; 72(3):238-45. PubMed ID: 15662652 [TBL] [Abstract][Full Text] [Related]
5. Surface characteristics, biocompatibility, and mechanical properties of nickel-titanium plasma-implanted with nitrogen at different implantation voltages. Liu XM; Wu SL; Chan YL; Chu PK; Chung CY; Chu CL; Yeung KW; Lu WW; Cheung KM; Luk KD J Biomed Mater Res A; 2007 Aug; 82(2):469-78. PubMed ID: 17295249 [TBL] [Abstract][Full Text] [Related]
6. Surface characteristics, mechanical properties, and cytocompatibility of oxygen plasma-implanted porous nickel titanium shape memory alloy. Wu SL; Chu PK; Liu XM; Chung CY; Ho JP; Chu CL; Tjong SC; Yeung KW; Lu WW; Cheung KM; Luk KD J Biomed Mater Res A; 2006 Oct; 79(1):139-46. PubMed ID: 16779766 [TBL] [Abstract][Full Text] [Related]
7. Improvement of surface bioactivity on titanium by water and hydrogen plasma immersion ion implantation. Xie Y; Liu X; Huang A; Ding C; Chu PK Biomaterials; 2005 Nov; 26(31):6129-35. PubMed ID: 15885768 [TBL] [Abstract][Full Text] [Related]
8. Surface structure and properties of biomedical NiTi shape memory alloy after Fenton's oxidation. Chu CL; Hu T; Wu SL; Dong YS; Yin LH; Pu YP; Lin PH; Chung CY; Yeung KW; Chu PK Acta Biomater; 2007 Sep; 3(5):795-806. PubMed ID: 17466609 [TBL] [Abstract][Full Text] [Related]
9. Surface properties and cell response of low metal ion release Ti-6Al-7Nb alloy after multi-step chemical and thermal treatments. Spriano S; Bosetti M; Bronzoni M; Vernè E; Maina G; Bergo V; Cannas M Biomaterials; 2005 Apr; 26(11):1219-29. PubMed ID: 15475051 [TBL] [Abstract][Full Text] [Related]
10. Biomimetic deposition of apatite coating on surface-modified NiTi alloy. Gu YW; Tay BY; Lim CS; Yong MS Biomaterials; 2005 Dec; 26(34):6916-23. PubMed ID: 15941583 [TBL] [Abstract][Full Text] [Related]
11. Effect of calcium and phosphorus ion implantation on the corrosion resistance and biocompatibility of titanium. Krupa D; Baszkiewicz J; Kozubowski JA; Lewandowska-Szumieł M; Barcz A; Sobczak JW; Biliński A; Rajchel A Biomed Mater Eng; 2004; 14(4):525-36. PubMed ID: 15472399 [TBL] [Abstract][Full Text] [Related]
13. Bioactivity of titanium following sodium plasma immersion ion implantation and deposition. Maitz MF; Poon RW; Liu XY; Pham MT; Chu PK Biomaterials; 2005 Sep; 26(27):5465-73. PubMed ID: 15860203 [TBL] [Abstract][Full Text] [Related]
14. A comparative study of the cytotoxicity and corrosion resistance of nickel-titanium and titanium-niobium shape memory alloys. McMahon RE; Ma J; Verkhoturov SV; Munoz-Pinto D; Karaman I; Rubitschek F; Maier HJ; Hahn MS Acta Biomater; 2012 Jul; 8(7):2863-70. PubMed ID: 22465573 [TBL] [Abstract][Full Text] [Related]
15. Effect of oxygen plasma immersion ion implantation treatment on corrosion resistance and cell adhesion of titanium surface. Yang CH; Wang YT; Tsai WF; Ai CF; Lin MC; Huang HH Clin Oral Implants Res; 2011 Dec; 22(12):1426-32. PubMed ID: 21457349 [TBL] [Abstract][Full Text] [Related]
16. Plasma-treated nanostructured TiO(2) surface supporting biomimetic growth of apatite. Liu X; Zhao X; Fu RK; Ho JP; Ding C; Chu PK Biomaterials; 2005 Nov; 26(31):6143-50. PubMed ID: 15927251 [TBL] [Abstract][Full Text] [Related]
17. [Corrosion behaviour, metal release and biocompatibility of implant materials coated by TiO2-sol gel chemistry]. Hoffmann B; Kokott A; Shafranska O; Detsch R; Winter S; Eisenbarth E; Peters K; Breme J; Kirkpatrick CJ; Ziegler G Biomed Tech (Berl); 2005 Oct; 50(10):320-9. PubMed ID: 16300047 [TBL] [Abstract][Full Text] [Related]
18. Corrosion behavior of shape memory, superelastic, and nonsuperelastic nickel-titanium-based orthodontic wires at various temperatures. Pun DK; Berzins DW Dent Mater; 2008 Feb; 24(2):221-7. PubMed ID: 17624421 [TBL] [Abstract][Full Text] [Related]
19. Corrosion resistance of a laser spot-welded joint of NiTi wire in simulated human body fluids. Yan XJ; Yang DZ J Biomed Mater Res A; 2006 Apr; 77(1):97-102. PubMed ID: 16392124 [TBL] [Abstract][Full Text] [Related]
20. Effect of the M(s) transformation temperature on the wear behaviour of NiTi shape memory alloys for articular prosthesis. Peña J; Solano E; Mendoza A; Casals J; Planell JA; Gil FJ Biomed Mater Eng; 2005; 15(4):289-93. PubMed ID: 16010037 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]